Rate of Stenotic Bicuspid Aortic Valve Aortic Dilatation After Aortic Valve Replacement, Calculated Using a 3-Dimensional Reconstruction Tool.

Kaoru Hattori1, Ikuo Fukuda1, Kazuyuki Daitoku1, Masahito Minakawa1, Hiroyuki Itaya1.   

Abstract

BACKGROUND: Progression of asymmetric dilated aorta associated with bicuspid aortic valve (BAV) is difficult to evaluate conventionally. The aim of the study was to calculate the rate of progression of the dilated BAV aorta after aortic valve replacement (AVR) using a 3-dimensional (3-D) reconstruction tool.Methods and 
Results: Fourteen stenotic BAV and 14 stenotic tricuspid aortic valve (TAV) patients with mildly dilated ascending aorta were reviewed. A patient-specific 3-D aortic model was reconstructed from preoperative and postoperative computed tomography data (BAV, 2.5±1.9 years after AVR; TAV, 2.2±1.8 years after AVR). Aortic diameter, including the longest and shortest, was measured on the maximum perpendicular cross-section tangential to the 3-D centerline of the reconstructed model. The longest diameter was defined as that passing through the distal point of the greater curvature of the aorta. The shortest diameter was defined as perpendicular to the longest. The progression rates were compared between the BAV and TAV groups. The progression rate of ascending aortic diameter was greater for BAV (longest diameter, 1.02±1.03 vs. -0.075±0.78 mm/year, P<0.001; shortest diameter, 0.41±0.62 vs. -0.016±0.59 mm/year, P=0.003). The longest diameter of the proximal arch also grew more rapidly in the BAV group (P<0.001).
CONCLUSIONS: Ascending aortic dilatation with stenotic BAV progresses after AVR at a maximum rate of 1.02±1.03 mm/year. Expansion toward the greater curvature frequently progresses to the proximal arch.

Entities:  

Keywords:  Aortic valve; Asymmetric aneurysm; Reconstruction tool

Mesh:

Year:  2017        PMID: 28367857     DOI: 10.1253/circj.CJ-16-0974

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  2 in total

1.  Bicuspid aortic valve morphology and aortic valvular outflow jets: an experimental analysis using an MRI-compatible pulsatile flow circulation system.

Authors:  Kaoru Hattori; Natsuki Nakama; Jumpei Takada; Gohki Nishimura; Ryo Moriwaki; Eita Kawasaki; Michinobu Nagao; Yasuhiro Goto; Hiroshi Niinami; Kiyotaka Iwasaki
Journal:  Sci Rep       Date:  2021-01-22       Impact factor: 4.379

2.  Surgical treatment of mild to moderately dilated ascending aorta in bicuspid aortic valve aortopathy: the art of safety and simplicity.

Authors:  Peng Zhu; Pengyu Zhou; Xiao Ling; Bright Eric Ohene; Xiao Ming Bian; Xiaoxiao Jiang
Journal:  J Cardiothorac Surg       Date:  2020-01-17       Impact factor: 1.637

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.