Literature DB >> 28366450

How much does experience in guided implant surgery play a role in accuracy? A randomized controlled pilot study.

M Cassetta1, M Bellardini2.   

Abstract

The current literature is not consistent on whether experience influences accuracy. The aim of this study was to analyze the accuracy of implant insertion performed by inexperienced versus experienced surgeons. Thirty-three implants were inserted by the inexperienced group and 37 implants by the experienced group. Planning and post-surgical computed tomography images were matched and the accuracy data compared. The positioning error was also evaluated. Quantitative data for the two groups were described and illustrated using box plots. The t-test was used to compare accuracy values and positioning error. Significance was set at P≤0.05. In the inexperienced group, the mean coronal, apical, and angular deviation values were 0.75mm (range 1.01-0.51, standard deviation (SD) 0.18), 1.02mm (range 1.99-0.64, SD 0.44), and 3.07° (range 9.22-0.73, SD 2.70). In the experienced group, the mean coronal, apical, and angular deviations were 0.60mm (range 1.00-0.06, SD 0.25), 0.67mm (range 1.67-0.24, SD 0.34), and 3.21° (range 8.01-1.41, SD 1.57). The t-test did not show any statistically significant difference when coronal (P=0.125), apical (P=0.060), and angular (P=0.859) deviations were considered. A statistically significant difference (P=0.000) was determined when the positioning error was considered. Experience had a limited influence on accuracy, but reduced positioning error to a statistically significant degree.
Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Keywords:  clinical research; computer-assisted surgery; dental implants; positioning error; randomized controlled trial

Mesh:

Year:  2017        PMID: 28366450     DOI: 10.1016/j.ijom.2017.03.010

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  7 in total

Review 1.  Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis.

Authors:  Adrià Jorba-García; Albert González-Barnadas; Octavi Camps-Font; Rui Figueiredo; Eduard Valmaseda-Castellón
Journal:  Clin Oral Investig       Date:  2021-02-26       Impact factor: 3.573

2.  Accuracy of half-way mucosa-supported implant guides for edentulous jaws: a retrospective study with a median follow-up of 2 years.

Authors:  Weiwei Tang; Qilong Liu; Xianshang Zeng; Jiali Yu; Dalong Shu; Guorong Shen; Weiguang Yu; Xiangzhen Liu; Guixing Xu
Journal:  J Int Med Res       Date:  2021-03       Impact factor: 1.671

Review 3.  Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: a Systematic Review.

Authors:  Cheongbeom Seo; Gintaras Juodzbalys
Journal:  J Oral Maxillofac Res       Date:  2018-03-31

4.  Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial.

Authors:  Sigmar Schnutenhaus; Liesa Brunken; Cornelia Edelmann; Jens Dreyhaupt; Heike Rudolph; Ralph G Luthardt
Journal:  BMC Oral Health       Date:  2020-06-29       Impact factor: 2.757

5.  Multivariate analysis of causal factors influencing accuracy of guided implant surgery for partial edentulism: a retrospective clinical study.

Authors:  Atsushi Matsumura; Tamaki Nakano; Shinji Ono; Akihiro Kaminaka; Hirofumi Yatani; Daijiro Kabata
Journal:  Int J Implant Dent       Date:  2021-04-19

Review 6.  Accuracy of Computer-Assisted Flapless Implant Placement by Means of Mucosa-Supported Templates in Complete-Arch Restorations: A Systematic Review.

Authors:  Paolo Carosi; Claudia Lorenzi; Fabrizio Lio; Pierluigi Cardelli; Alessandro Pinto; Andrea Laureti; Alessandro Pozzi
Journal:  Materials (Basel)       Date:  2022-02-16       Impact factor: 3.623

7.  A Novel Guided Zygomatic and Pterygoid Implant Surgery System: A Human Cadaver Study on Accuracy.

Authors:  Francesco Grecchi; Luigi V Stefanelli; Fabrizio Grivetto; Emma Grecchi; Rami Siev; Ziv Mazor; Massimo Del Fabbro; Nicola Pranno; Alessio Franchina; Vittorio Di Lucia; Francesca De Angelis; Funda Goker
Journal:  Int J Environ Res Public Health       Date:  2021-06-07       Impact factor: 3.390

  7 in total