Diagnostic accuracy of ultrasonography for detecting nasogastric tube (NGT) placement in adults: A systematic review and meta analysis.

Tian Lin1, Wendy Gifford2, Yutao Lan1, Xiuqun Qin3, Xuelian Liu3, Juan Wang1, Biping Yang1, Tianhui You4, Ken Chen5.   

Abstract

OBJECTIVE: To review the evidence on diagnostic accuracy of ultrasonography for detecting correct nasogastric tube (NGT) placement in adults compared to X-ray as the reference standard.
METHODS: This is a systematic review and meta-analysis of observational studies, searched in the literature between 1961 and 2015. We included studies which compared the diagnostic accuracy of ultrasonography detection for NGT placement with X-ray in adult patients who were undergoing NGT placement for any reason in any care setting. We searched published studies in the following electronic databases: Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, Web of Science, WanFang Data, China Journal Net, and the Chinese Biomedical Literature Database. Both English and non-English-language articles were retrieved. Risk of bias was assessed using a standard procedure according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria.
RESULTS: We included five studies involving a total of 420 adult patients undergoing nasogastric tube placement: three trials were undertaken in mechanically ventilated patients in prehospital settings and two involved participants with comma or severe trauma in emergency room or intensive care unit (ICU). Pooled results showed that ultrasonography had a sensitivity of 0.93 (95% CI 0.87 to 0.97), and specificity of 0.97 (95% CI 0. 23 to 1.00), suggesting that diagnostic performance of ultrasound is useful to confirm correct NGT placement, but not optimal to detect incorrect NGT position. This was confirmed through a summary receiver operator characteristics (SROC) curve that showed the area under the curve was 0.96 (95% CI 0.94 to 0.98). DISCUSSION: The main limitation of the review is the relatively moderate level of heterogeneity of included studies which may partially undermine the reliability and reproducibility of results. The insufficient studies included did not allow identification of possible sources of heterogeneity and exploration of reporting bias. Due to heterogeneity of studies, the diagnostic performance of ultrasonography could only be drawn cautiously. Physicians and nurses should perform routine X-ray if visualization of NGT is not possible. More well designed studies exploring ultrasound as a diagnostic tool for accuracy of NGT placement are needed to strengthen the current evidence.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Adult; Nasogastric tube; Systematic review; Ultrasonography

Mesh:

Year:  2017        PMID: 28359986     DOI: 10.1016/j.ijnurstu.2017.03.005

Source DB:  PubMed          Journal:  Int J Nurs Stud        ISSN: 0020-7489            Impact factor:   5.837


  2 in total

Review 1.  Nasoenteric tube doppler guided insertion. A case report and review of literature.

Authors:  Sebastián Pablo Chapela; Emiliano Jorge Descotte; María Jimena Reberendo
Journal:  Eur J Clin Nutr       Date:  2021-10-22       Impact factor: 4.884

2.  Ultrasonographic Confirmation of Nasogastric Tube Placement in the COVID-19 Era.

Authors:  Vasiliki Tsolaki; George E Zakynthinos; Paris Zygoulis; Fotini Bardaka; Aikaterini Malita; Vasileios Aslanidis; Epaminondas Zakynthinos; Demosthenes Makris
Journal:  J Pers Med       Date:  2022-02-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.