Bedside nuclear probe for detection and quantification of left to right intracardiac shunts.

B A Gould1, J Turner, D H Keeling, N J Ring, R R Cox, A J Marshall.   

Abstract

A cadmium telluride nuclear probe with an Elscint gamma camera was used to detect and measure left to right intracardiac shunts at the bedside in 34 patients. Fifteen also had right heart catheterisation and oximetric measurement of the shunt. For the nuclear technique 740 MBq (20 mCi) of technetium-99m pertechnetate was injected into the right antecubital vein and the pulmonary to systemic flow ratio (QP:QS) was measured by the gamma variate technique. Data were not obtained in four patients because the nuclear probe failed in three patients and one storage disc was corrupted. Data from the gamma camera were lost in another patient. When the size of the shunt measured by the nuclear probe was compared with that measured by the oximetric technique the mean difference (SD of mean difference) was 0.36 (SD 0.78) and when it was compared with the gamma camera it was 0.08 (SD 0.67). Analysis of scatter plots showed that the larger the shunt, the larger the discrepancy. Twenty four of 29 data sets showed complete agreement between the nuclear probe and gamma camera on the size of the shunt. Any differences were small. These data indicate that left to right intracardiac shunts may be measured accurately by a nuclear probe at the bedside in either the coronary care unit or outpatient department.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2835974      PMCID: PMC1216492          DOI: 10.1136/hrt.59.4.463

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  8 in total

1.  Reliability of a spectrophotometric method of estimating blood oxygen.

Authors:  H E HOLLING; I MACDONALD; J A O'HALLORAN; A VENNER
Journal:  J Appl Physiol       Date:  1955-11       Impact factor: 3.531

2.  Comparison of formulae used to estimate oxygen saturation of mixed venous blood from caval samples.

Authors:  H C Miller; D J Brown; G A Miller
Journal:  Br Heart J       Date:  1974-05

3.  Quantitation of left-to-right cardiac shunts with radionuclide angiography.

Authors:  P A Anderson; R H Jones; D C Sabiston
Journal:  Circulation       Date:  1974-03       Impact factor: 29.690

4.  Deconvolution analysis in radionuclide quantitation of left-to-right cardiac shunts.

Authors:  P O Alderson; K H Douglass; K G Mendenhall; V A Guadiani; D C Watson; J M Links; H N Wagner
Journal:  J Nucl Med       Date:  1979-06       Impact factor: 10.057

5.  Quantitative radionuclide angiocardiography: detection and quantitation of left to right shunts.

Authors:  J Askenazi; D S Ahnberg; E Korngold; C G LaFarge; D L Maltz; S Treves
Journal:  Am J Cardiol       Date:  1976-03-04       Impact factor: 2.778

6.  Combined contrast echocardiographic and radionuclide diagnosis of atrial septal defect: accuracy of the technique and analysis of erroneous diagnoses.

Authors:  L E Ginzton; W French; I Mena
Journal:  Am J Cardiol       Date:  1984-06-01       Impact factor: 2.778

7.  Superiority of radionuclide over oximetric measurement of left to right shunts.

Authors:  E J Baker; S V Ellam; A Lorber; O D Jones; M J Tynan; M N Maisey
Journal:  Br Heart J       Date:  1985-05

8.  Current value of radionuclide angiocardiography for shunt quantification and management in patients with secundum atrial septal defect.

Authors:  R A Hurwitz; S Treves; J F Keane; D A Girod; R L Caldwell
Journal:  Am Heart J       Date:  1982-03       Impact factor: 4.749

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.