Clinical performance of Rb-82 myocardial perfusion PET and Tc-99m-based SPECT in patients with extreme obesity.

David T Harnett1, Samir Hazra1, Ronnen Maze2, Brian A Mc Ardle1, Ali Alenazy1, Trevor Simard2, Ellen Henry1, Girish Dwivedi1, Christopher Glover2, Robert A deKemp1, Ross A Davies1, Terrence D Ruddy1, Benjamin J W Chow1, Rob S Beanlands1, Benjamin Hibbert3.   

Abstract

BACKGROUND: We evaluated the performance of stress imaging with technetium-99m-labeled tetrofosmin single-photon emission computed tomography (SPECT) and rubidium-82 positron emission tomography (PET) in patients with extreme obesity, defined as body mass index ≥40 kg/m2.
METHODS: We identified patients with extreme obesity who underwent angiography in our center and either stress SPECT or PET within the previous six months. Cohorts of patients with extreme obesity and a <5% pretest likelihood of CAD who underwent SPECT (N = 25) or PET (N = 25) were also included.
RESULTS: In total, 108 patients who underwent SPECT (N = 57) or PET (N = 51) were identified. Scan interpretation was classified as definitely normal or abnormal in 83.3% of PET and 60.5% of SPECT scans, respectively (P < .01). PET demonstrated higher diagnostic accuracy and normalcy rate. PET was found to have higher specificity for the pooled cohort. Similar findings were observed using stenosis cut-offs of ≥50% and ≥70%.
CONCLUSIONS: In patients with extreme obesity, PET enabled more definitive scan interpretation with less artifact compared to SPECT. PET provided higher diagnostic accuracy and specificity in the detection of obstructive coronary artery disease.

Entities:  

Keywords:  Myocardial perfusion imaging; PET/CT; SPECT; obesity

Year:  2017        PMID: 28357812     DOI: 10.1007/s12350-017-0855-6

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  32 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Waren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Int J Cardiovasc Imaging       Date:  2002-02       Impact factor: 2.357

2.  Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for myocardial ischemia.

Authors:  Maria C Ziadi; Robert A Dekemp; Kathryn A Williams; Ann Guo; Benjamin J W Chow; Jennifer M Renaud; Terrence D Ruddy; Niroshi Sarveswaran; Rebecca E Tee; Rob S B Beanlands
Journal:  J Am Coll Cardiol       Date:  2011-08-09       Impact factor: 24.094

3.  Biodistribution and radiation dosimetry of (82)Rb at rest and during peak pharmacological stress in patients referred for myocardial perfusion imaging.

Authors:  Chad R R N Hunter; Jeremy Hill; M Cecilia Ziadi; Rob S B Beanlands; Robert A deKemp
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-03-28       Impact factor: 9.236

4.  ASNC imaging guidelines/SNMMI procedure standard for positron emission tomography (PET) nuclear cardiology procedures.

Authors:  Vasken Dilsizian; Stephen L Bacharach; Rob S Beanlands; Steven R Bergmann; Dominique Delbeke; Sharmila Dorbala; Robert J Gropler; Juhani Knuuti; Heinrich R Schelbert; Mark I Travin
Journal:  J Nucl Cardiol       Date:  2016-07-08       Impact factor: 5.952

5.  SPECT myocardial perfusion imaging in morbidly obese patients: image quality, hemodynamic response to pharmacologic stress, and diagnostic and prognostic value.

Authors:  W Lane Duvall; Lori B Croft; Jared S Corriel; Andrew J Einstein; Jonathan E Fisher; Pilar S Haynes; Randi K Rose; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

6.  Half-time SPECT myocardial perfusion imaging with attenuation correction.

Authors:  Iftikhar Ali; Terrence D Ruddy; Abdulaziz Almgrahi; Frank G Anstett; R Glenn Wells
Journal:  J Nucl Med       Date:  2009-03-16       Impact factor: 10.057

Review 7.  Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease?: A systematic review and meta-analysis.

Authors:  Brian A Mc Ardle; Taylor F Dowsley; Robert A deKemp; George A Wells; Rob S Beanlands
Journal:  J Am Coll Cardiol       Date:  2012-10-03       Impact factor: 24.094

8.  Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT.

Authors:  Timothy M Bateman; Gary V Heller; A Iain McGhie; John D Friedman; James A Case; Jan R Bryngelson; Ginger K Hertenstein; Kelly L Moutray; Kimberly Reid; S James Cullom
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

9.  Diagnostic accuracy and impact of computed tomographic coronary angiography on utilization of invasive coronary angiography.

Authors:  Benjamin J W Chow; Arun Abraham; George A Wells; Li Chen; Terrence D Ruddy; Yeung Yam; Nayia Govas; Phoebe Diane Galbraith; Carole Dennie; Rob S Beanlands
Journal:  Circ Cardiovasc Imaging       Date:  2009-01       Impact factor: 7.792

10.  Cardiovascular evaluation and management of severely obese patients undergoing surgery: a science advisory from the American Heart Association.

Authors:  Paul Poirier; Martin A Alpert; Lee A Fleisher; Paul D Thompson; Harvey J Sugerman; Lora E Burke; Picard Marceau; Barry A Franklin
Journal:  Circulation       Date:  2009-06-15       Impact factor: 29.690

View more
  4 in total

1.  Coronary Microvascular Dysfunction and Cardiovascular Risk in Obese Patients.

Authors:  Navkaranbir S Bajaj; Michael T Osborne; Ankur Gupta; Ali Tavakkoli; Paco E Bravo; Tomas Vita; Courtney F Bibbo; Jon Hainer; Sharmila Dorbala; Ron Blankstein; Deepak L Bhatt; Marcelo F Di Carli; Viviany R Taqueti
Journal:  J Am Coll Cardiol       Date:  2018-08-14       Impact factor: 24.094

2.  SPECT but not PET remains as the working horse of the state of the art nuclear cardiac imaging laboratory: Con.

Authors:  Antti Saraste; Juhani Knuuti
Journal:  J Nucl Cardiol       Date:  2017-07-31       Impact factor: 5.952

3.  EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging.

Authors:  Roberto Sciagrà; Mark Lubberink; Fabien Hyafil; Antti Saraste; Riemer H J A Slart; Denis Agostini; Carmela Nappi; Panagiotis Georgoulias; Jan Bucerius; Christoph Rischpler; Hein J Verberne
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-11-02       Impact factor: 9.236

Review 4.  New Radionuclides and Technological Advances in SPECT and PET Scanners.

Authors:  Nicholas P van der Meulen; Klaus Strobel; Thiago Viana Miranda Lima
Journal:  Cancers (Basel)       Date:  2021-12-08       Impact factor: 6.639

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.