Literature DB >> 28357687

Efficacy and safety of non-suture dural closure using a novel dural substitute consisting of polyglycolic acid felt and fibrin glue to prevent cerebrospinal fluid leakage-A non-controlled, open-label, multicenter clinical trial.

Shunsuke Terasaka1, Toshiaki Taoka2, Satoshi Kuroda3, Nobutaka Mikuni4, Toru Nishi5, Hiroyuki Nakase6, Yukihiko Fujii7, Yasuhiko Hayashi8, Jun-Ichi Murata9, Ken-Ichiro Kikuta10, Toshihiko Kuroiwa11, Sachie Shimokawa12, Kiyohiro Houkin13.   

Abstract

The objective of this study is to evaluate the efficacy and safety of non-suture dural closure using a novel dural substitute (GM111) consisting of polyglycolic acid felt with a fibrin-glue-coated area commensurate in size with the dural defect. This was a non-controlled, open-label, multicenter clinical trial. The efficacy evaluation endpoints were (1) GM111's intra-operative capability to close dural defects and (2) prevention of cerebrospinal fluid (CSF) leakage and subcutaneous CSF retention throughout the postoperative period (evaluated by diagnostic imaging). Patients meeting the following three preoperative and two intra-operative selection criteria were enrolled: (1) between 12 and <75 years of age; (2) the dura is surmised to be defective and in need of reconstruction; (3) informed written consent was obtained from the patient; (4) the surgical wound is class 1; and (5) the size of duraplasty is ≥0.2 cm2 to <100 cm2. Sixty patients were enrolled. The craniotomy site was supratentorial in 77.2%, infratentorial in 12.3% and sellar in 10.5%. The GM111 prosthesis size ranged from 0.24 to 42 cm2. To evaluate the efficacy, intra-operative closure was confirmed by Valsalva's maneuver, water infusion, etc., in all patients. CSF leakage and subcutaneous CSF retention throughout the postoperative period were found in four patients. Adverse events for which a causal relationship with GM111 could not be ruled out occurred in 8.8% of the patients. There were no instances of postoperative infection due to GM111. GM111 showed good closure capability and safety when used for non-suture dural closure.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28357687     DOI: 10.1007/s10856-017-5877-8

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  16 in total

1.  Clinical application of a new bioabsorbable artificial dura mater.

Authors:  Keisuke Yamada; Susumu Miyamoto; Motohiro Takayama; Izumi Nagata; Nobuo Hashimoto; Yoshito Ikada; Haruhiko Kikuchi
Journal:  J Neurosurg       Date:  2002-04       Impact factor: 5.115

2.  [A novel method of dural repair using polyglycolic acid non-woven fabric and fibrin glue: clinical results of 140 cases].

Authors:  Shunsuke Terasaka; Yoshinobu Iwasaki; Satoshi Kuroda; Takanori Uchida
Journal:  No Shinkei Geka       Date:  2006-11

3.  The incidence of complications in elective cranial neurosurgery associated with dural closure material.

Authors:  Brian P Walcott; Jonathan B Neal; Sameer A Sheth; Kristopher T Kahle; Emad N Eskandar; Jean-Valery Coumans; Brian V Nahed
Journal:  J Neurosurg       Date:  2013-09-13       Impact factor: 5.115

4.  Cerebrospinal fluid (CSF) leak and pseudomeningocele formation after posterior fossa tumor resection in children: a retrospective analysis.

Authors:  P Steinbok; A Singhal; J Mills; D D Cochrane; A V Price
Journal:  Childs Nerv Syst       Date:  2006-09-19       Impact factor: 1.475

5.  Experience with acellular human dura and bovine collagen matrix for duraplasty after posterior fossa decompression for Chiari malformations.

Authors:  Shabbar F Danish; Amer Samdani; Amgad Hanna; Phillip Storm; Leslie Sutton
Journal:  J Neurosurg       Date:  2006-01       Impact factor: 5.115

6.  Primary closure of a cerebrospinal fluid fistula by nonpenetrating titanium clips in endoscopic endonasal transsphenoidal surgery: technical note.

Authors:  Hiroyuki Kobayashi; Katsuyuki Asaoka; Shunsuke Terasaka; Jun-Ich Murata
Journal:  Skull Base       Date:  2011-01

7.  Posterior cranial fossa surgery in 454 children. Comparison of results obtained in pre-CT and CT era and after various types of management of dura mater.

Authors:  J Parízek; P Mericka; S Nemecek; J Nemecková; J Spacek; P Suba; M Sercl
Journal:  Childs Nerv Syst       Date:  1998-09       Impact factor: 1.475

8.  Risk factors for postoperative CSF leakage after elective craniotomy and the efficacy of fleece-bound tissue sealing against dural suturing alone: a randomized controlled trial.

Authors:  Gregor Hutter; Stefanie von Felten; Martin H Sailer; Marianne Schulz; Luigi Mariani
Journal:  J Neurosurg       Date:  2014-07-18       Impact factor: 5.115

9.  Fibrin glue and polyglycolic Acid nonwoven fabric as a biocompatible dural substitute.

Authors:  Shunsuke Terasaka; Yoshinobu Iwasaki; Noriko Shinya; Takanori Uchida
Journal:  Neurosurgery       Date:  2006-02       Impact factor: 4.654

10.  Postoperative complications associated with dural substitutes in suboccipital craniotomies.

Authors:  Shaye I Moskowitz; James Liu; Ajit A Krishnaney
Journal:  Neurosurgery       Date:  2009-03       Impact factor: 4.654

View more
  3 in total

1.  A new technology for reducing anastomotic fistula in the neck after esophageal cancer surgery.

Authors:  Ya-Nan Song; Yu Qi; Chun-Yang Zhang; Yin-Liang Sheng; Kai Wu; Sen-Lin Zhu; Lu Han; Ting-Ting Shan; Guan-Chao Ye; Qing-Yi Zhang; Yan-Li Chen; Jin-Wei Chen; Ya-Fei Liu; Lu-Bing Gao; Yang Yang; Zhan-Feng He; Deng-Yan Zhu; Dong-Lei Liu; Feng-Biao Wen; Tian-Liang Zheng; Ji-Lun Li; Song Zhao
Journal:  J Thorac Dis       Date:  2019-07       Impact factor: 2.895

2.  Efficacy and safety of polyethylene glycol dural sealant system in cranial and spinal neurosurgical procedures: Meta-analysis.

Authors:  Ahmed Diab; Hieder Al-Shami; Ahmed Negida; Ahmed Gadallah; Hossam Farag; Doaa Mahmoud Elkadi; Mo'tasem Muhamed Gaber; Mahmoud Ahmed Ebada
Journal:  Surg Neurol Int       Date:  2021-04-26

3.  Application of osteoinductive calcium phosphate ceramics in children's endoscopic neurosurgery: report of five cases.

Authors:  Jia Wei; Hufei Qian; Yu Liu; Jiangang Liu; Rui Zhao; Xiao Yang; Xiangdong Zhu; Ruoping Chen; Xingdong Zhang
Journal:  Regen Biomater       Date:  2018-05-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.