Literature DB >> 28346001

Assessment of contrast-enhanced ultrasonography of the hepatic vein for detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs.

Keitaro Morishita, Akira Hiramoto, Asuka Michishita, Satoshi Takagi, Yuki Hoshino, Takaharu Itami, Sue Yee Lim, Tatsuyuki Osuga, Sayuri Nakamura, Kenji Ochiai, Kensuke Nakamura, Hiroshi Ohta, Masahiro Yamasaki, Mitsuyoshi Takiguchi.   

Abstract

OBJECTIVE To assess the use of contrast-enhanced ultrasonography (CEUS) of the hepatic vein for the detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs. ANIMALS 6 healthy Beagles. PROCEDURES A prospective study was conducted. A catheter was surgically placed in the portal vein of each dog. Hypertension was induced by intraportal injection of microspheres (10 to 15 mg/kg) at 5-day intervals via the catheter. Microsphere injections were continued until multiple acquired portosystemic shunts were created. Portal vein pressure (PVP) was measured through the catheter. Contrast-enhanced ultrasonography was performed before and after establishment of hypertension. Time-intensity curves were generated from the region of interest in the hepatic vein. Perfusion variables measured for statistical analysis were hepatic vein arrival time, time to peak, time to peak phase (TTPP), and washout ratio. The correlation between CEUS variables and PVP was assessed by use of simple regression analysis. RESULTS Time to peak and TTPP were significantly less after induction of portal hypertension. Simple regression analysis revealed a significant negative correlation between TTPP and PVP. CONCLUSIONS AND CLINICAL RELEVANCE CEUS was useful for detecting hemodynamic changes associated with experimentally induced portal hypertension in dogs, which was characterized by a rapid increase in the intensity of the hepatic vein. Furthermore, TTPP, a time-dependent variable, provided useful complementary information for predicting portal hypertension. IMPACT FOR HUMAN MEDICINE Because the method described here induced presinusoidal portal hypertension, these results can be applied to idiopathic portal hypertension in humans.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28346001     DOI: 10.2460/ajvr.78.4.465

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  3 in total

1.  Washout Ratio in the Hepatic Vein Measured by Contrast-Enhanced Ultrasonography to Distinguish Between Inflammatory and Noninflammatory Hepatic Disorders in Dogs.

Authors:  K Morishita; A Hiramoto; A Michishita; S Takagi; T Osuga; S Y Lim; K Nakamura; N Sasaki; H Ohta; M Takiguchi
Journal:  J Vet Intern Med       Date:  2017-04-05       Impact factor: 3.333

2.  Application of Contrast-Enhanced Ultrasound Combined with Elastic Imaging Technology in Differential Diagnosis of Salivary Gland Tumors.

Authors:  Hong Chen; Xinyu Bao; Long Wan
Journal:  J Healthc Eng       Date:  2022-04-12       Impact factor: 3.822

3.  Sildenafil does not have a significant effect on the portal vein velocity, cross-sectional area, and congestion index in the dog.

Authors:  Christopher R Tollefson; Marc A Seitz; Claudio C Natalini; Alison M Lee
Journal:  Front Vet Sci       Date:  2022-07-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.