Intravascular ultrasonography guided 60-mm long drug-eluting tapered stent implantation in a long calcified lesion in a patient with stable coronary artery disease.

Jakub Podolec1, Jakub Baran1, Łukasz Niewiara1, Piotr Odrowąż-Pieniążek1, Krzysztof Żmudka1.   

Abstract

Entities:  

Year:  2017        PMID: 28344627      PMCID: PMC5364292          DOI: 10.5114/aic.2017.66196

Source DB:  PubMed          Journal:  Postepy Kardiol Interwencyjnej        ISSN: 1734-9338            Impact factor:   1.426


× No keyword cloud information.
Patients with stable coronary artery disease and diffuse long lesions are becoming more often a challenge for interventional cardiologists. Complete revascularization often requires implantation of many stents into a single artery. Overlapping of stents, required for drug-eluting stents (DES), leads to higher metal density, which is also potentially more favorable for healing problems and cardiac events [1-3]. A 62-year-old patient with hypertension, diabetes and dyslipidemia presented to the Department of Interventional Cardiology, Jagiellonian University College of Medicine in the John Paul II Hospital with moderate to severe angina (class II/III according to the Canadian Cardiovascular Society Classification), diagnosed 2 months ago with coronary artery disease. According to Heart Team qualification, the patient was admitted to a referral invasive cardiology center to perform left anterior descending (LAD) angioplasty (Figure 1). The fractional flow reserve (FFR) result of 0.6 confirmed severity of the stenosis. Coronary angiography was performed and revealed a long calcified lesion in the proximal and mid segment of the LAD. Both the LAD and the diagonal (Dg) branch were secured with guide wires. To estimate the vessel diameter intravascular ultrasound (IVUS) was performed, but due to extensive arterial calcification in the proximal segment introduction of the Eagle eye IVUS catheter was impossible (Figure 1). Predilatation with a non-compliant balloon 3.0/15 mm up to 24 atm in the proximal and mid part was performed. Vessel diameter estimation after IVUS measurements was performed and revealed dissection in the mid part of the LAD. A 60 mm Sirolimus drug-eluting tapered Biomime morph stent with the proximal diameter of 3.0 and distal diameter of 2.5 mm was implanted without complications. The guidewire from the Dg branch was again introduced through the struts of the stent. The IVUS imaging showed a need of postdilatation in the mid part of the stent. Non-compliant 3.75/15 mm was used for optimization of the result. Kissing balloon technique was used to optimize the bifurcation result. The IVUS of the LAD also revealed non-critical distal dissection distally to the stent with slower blood flow to the distal part of the artery. A short 2.5/18 mm DES was implanted to cover the whole dissection distally. Final IVUS measurements revealed minimal lumen diameter (MLA) in the proximal part of the stent of 8.0 mm² and in the distal part 3.8 mm². Proximally the plaque edge burden was 45.5%, and distally 52.8%. The IVUS measurements confirmed the good angiographic result.
Figure 1

Long stenosis in the proximal and mid segment of the LAD prior to stent implantation (A, A’); stent introduction and positioning (B) stent implantation (B’); IVUS result prior to stent implantation (C) and after dilatation (C’); Final angiographic result (D)

Long stenosis in the proximal and mid segment of the LAD prior to stent implantation (A, A’); stent introduction and positioning (B) stent implantation (B’); IVUS result prior to stent implantation (C) and after dilatation (C’); Final angiographic result (D) The stent introduction after optimal lesion preparation with a non-compliant balloon was easy and predictable. Treatment of long lesions with single stent implantation is an interesting option for most patients and reduces the need for implantation of many overlapping stents.
  3 in total

1.  Interventional cardiology: does stent overlap make a difference to clinical outcome?

Authors:  Antonio Colombo; Rasha Al-Lamee
Journal:  Nat Rev Cardiol       Date:  2010-07       Impact factor: 32.419

2.  Impact of stent overlap on angiographic and long-term clinical outcome in patients undergoing drug-eluting stent implantation.

Authors:  Lorenz Räber; Peter Jüni; Lukas Löffel; Simon Wandel; Stéphane Cook; Peter Wenaweser; Mario Togni; Rolf Vogel; Christian Seiler; Franz Eberli; Thomas Lüscher; Bernhard Meier; Stephan Windecker
Journal:  J Am Coll Cardiol       Date:  2010-03-23       Impact factor: 24.094

3.  Impact of stent overlap on long-term clinical outcomes in patients treated with newer-generation drug-eluting stents.

Authors:  Crochan J O'Sullivan; Giulio G Stefanini; Lorenz Räber; Dik Heg; Masanori Taniwaki; Bindu Kalesan; Thomas Pilgrim; Thomas Zanchin; Aris Moschovitis; Lutz Büllesfeld; Ahmed A Khattab; Bernhard Meier; Peter Wenaweser; Peter Jüni; Stephan Windecker
Journal:  EuroIntervention       Date:  2014-01-22       Impact factor: 6.534

  3 in total
  1 in total

1.  Clinical experience with 12-month follow-up in patients after implantation of a novel long-tapered sirolimus drug-eluting stent.

Authors:  Jakub Podolec; Maciej Skubera; Łukasz Niewiara; Mateusz Podolec; Piotr Pieniążek; Krzysztof Bartuś; Krzysztof Żmudka; Jacek Legutko
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-03-15       Impact factor: 1.426

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.