Voltage-directed cavo-tricuspid isthmus ablation using a novel ablation catheter mapping technology in a myotonic dystrophy type I patient.

Vincenzo Russo1, Anna Rago1, Andrea Antonio Papa1, Federica Di Meo1, Carmine Ciardiello1, Giovanni Cimmino1, Gerardo Nigro1.   

Abstract

A successful case of maximum voltage-directed cavo-tricuspid isthmus (CTI) ablation using a novel ablation catheter mapping technology in a myotonic dystrophy type I (DM1) patient is reported. The patient complained recurrent episodes of atrial flutter, revealed by the atrio-ventricular electrograms analysis during the routine pacemaker controls.

Entities:  

Keywords:  atrial fibrillation; atrial flutter; cavo-tricuspid isthmus ablation; microelectrodes; myotonic dystrophy

Mesh:

Year:  2016        PMID: 28344442      PMCID: PMC5343742     

Source DB:  PubMed          Journal:  Acta Myol        ISSN: 1128-2460


Introduction

Myotonic dystrophy type 1 (DM1) is an autosomal dominant disorder resulting from an amplified CTG trinucleotide repeat (> 50) in the 3-prime untranslated region of the dystrophia myotonica protein kinase gene (DMPK gene) on chromosome 19q13.3. DM1 is the most common muscular dystrophy of the adult life with an incidence of 1 in 8000 births and a worldwide prevalence ranging from 2.1 to 14.3/100.000 inhabitants (1). Cardiac involvement is noticed in about 80% of cases, often preceding the skeletal muscle one (2). Paroxysmal supraventricular tachy-arrhythmias (atrial fibrillation, atrial flutter, atrial tachycardia) represent a common finding on 12 lead electrocardiograms (ECG) or 24 hour ECG-Holter monitoring, with a prevalence up to 25% (3). The patients are often asymptomatic. Atrial tachycardias are observed in up to 7.3% of patients, both as un-sustained and sustained forms (4). Atrial fibrillation/flutter (AF/AFl) frequently occurs in DM1 patients up to 17% (3, 4), some times representing the first manifestation of the muscular dystrophy in young patients (5). AF/AFl seems to increase mortality in this population (6). We report a successful case of maximum voltage-directed cavo-tricuspid isthmus (CTI) ablation using a novel ablation catheter mapping technology in a DM1 patient with recurrent episodes of typical atrial flutter.

Description

A 71-year-old woman with DM1 and arterial hypertension, with previously dual chambers pacemaker implantation for advanced atrio-ventricular block, was referred to our Division for device check and cardiologic therapy optimization. She never reported palpitations or arrhythmias-related symptoms, she didn't take antiarrhythmic medications. ECG showed a dual-chamber VDD paced rhythm at 60 bpm. Transthoracic echocardiogram showed normal left ventricular systolic function associated to grade I diastolic dysfunction. The device interrogation showed several episodes of sustained supraventricular tachycardia, with a cycle length of 289 ms (Fig. 1). AFl diagnosis was made by 24 h ECG Holter monitoring that showed the common features of typical CTI dependent atrial flutter. The patient underwent electrophysiological study (EPS) for catheter ablation of the arrhytmogenic substrate. Two decapolar diagnostic catheters were placed in the coronary sinus and in the lateral right atrium wall. An IntellaTip MiFi XP® (IntellaTip MiFi, Boston Scientific, Natick, MA) 8 mm RF catheter was used for CTI mapping and ablation (Fig. 2).
Figure 1.

Episode of sustained supraventricular tachycardia with a cycle length of 289 ms revealed by atrio-ventricular electrogram analyses during routine pacemaker control.

Figure 2.

Position of catheters in left anterior oblique (LAO) views during cavo-tricuspid isthmus (CTI) ablation. Two decapolar diagnostic catheters were placed in the coronary sinus and in the lateral right atrium wall. An IntellaTip MiFi XP® 8 mm RF catheter was positioned the 6 o'clock position across the CTI.

Episode of sustained supraventricular tachycardia with a cycle length of 289 ms revealed by atrio-ventricular electrogram analyses during routine pacemaker control. Position of catheters in left anterior oblique (LAO) views during cavo-tricuspid isthmus (CTI) ablation. Two decapolar diagnostic catheters were placed in the coronary sinus and in the lateral right atrium wall. An IntellaTip MiFi XP® 8 mm RF catheter was positioned the 6 o'clock position across the CTI. Prior to the onset of the ablation procedure, a baseline electrophysiology study was performed including the measurements of the baseline trans-isthmus interval. This was 112 ms when measured from the pacing stimulus on electrode 9/10 of the coronary sinus catheter to the atrial electrogram detected by electrode 1/2 on the Halo catheter (Fig. 3); and of 118 ms when measured from the pacing stimulus on electrode 1/2 of the HALO catheter to the atrial electrogram detected by electrode 9/10 on the coronary sinus catheter (Fig. 4). We performed a voltage-directed technique for ablating the only conducting bundles of the CTI, avoiding to ablate the intervening non-conducting fibrous tissue, according to previous experiences (7).
Figure 3.

Baseline trans-isthmus interval of 112 ms as measured from the pacing stimuli on electrode 9/10 of the coronary sinus catheter to the atrial electrogram detected by electrode 1/2 on the Halo catheter. In basal conditions the electrical impulse from the coronary sinus ostium spreads with two opposite wave fronts around the tricuspid valve, counterclockwise along the interatrial septum and clockwise along the back edge of the tricuspid.

Figure 4.

Baseline pacing trans-isthmus interval of 118 ms as measured from the pacing stimuli on electrode 1/2 of the HALO catheter to the atrial electrogram detected by electrode 9/10 on the coronary sinus catheter. In basal conditions the electrical impulse from the posterolateral tricuspid spreads around the tricuspid with two wave fronts, one in a clockwise direction (along the side wall) and another counterclockwise (along the rear wall and medial).

Baseline trans-isthmus interval of 112 ms as measured from the pacing stimuli on electrode 9/10 of the coronary sinus catheter to the atrial electrogram detected by electrode 1/2 on the Halo catheter. In basal conditions the electrical impulse from the coronary sinus ostium spreads with two opposite wave fronts around the tricuspid valve, counterclockwise along the interatrial septum and clockwise along the back edge of the tricuspid. Baseline pacing trans-isthmus interval of 118 ms as measured from the pacing stimuli on electrode 1/2 of the HALO catheter to the atrial electrogram detected by electrode 9/10 on the coronary sinus catheter. In basal conditions the electrical impulse from the posterolateral tricuspid spreads around the tricuspid with two wave fronts, one in a clockwise direction (along the side wall) and another counterclockwise (along the rear wall and medial). We firstly mapped across the CTI by pulling back from the tricuspid valve annulus to the inferior vena cava at the 6 o'clock position in left anterior oblique (LAO) projection. The signal voltage was noted during this pullback, and the highest voltage was identified. We returned to this location and have ablated it with an 8 mm dry tip for 40-60 s (60-70 W, 60-70 uC); this process was then repeated and continued until all sharp atrial electrograms detected on the mini-electrodes along the CTI were eliminated and only low-voltage double potentials were visible. A total of 3 radiofrequency ablation lesions were applied. We performed a post-procedure evaluation of pacing intervals from both electrode 9/10 of coronary sinus catheter and electrode 1/2 of the HALO catheter. We showed an increased trans-isthmus interval measured by both pacing from coronary sinus electrode 9/10 to the atrial electrogram detected by electrode 1/2 on the Halo catheter and from HALO electrode 1/2 to the atrial electrogram detected by electrode 9/10 on the coronary sinus catheter, of 144 and 140 ms, respectively confirming the bidirectional block (Figs. 5, 6).
Figure 5.

Post-procedure increased trans-isthmus interval as measured from the pacing stimuli on coronary sinus electrode 9/10 (144 ms) to the atrial electrogram detected by electrode 1/2 on the Halo catheter The electrical impulse is forced to activate the atrial peritricuspidal myocardium only counterclockwise.

Figure 6.

Post-procedure increased trans-isthmus interval as measured from HALO electrode (140 ms). The electrical impulse provided by the posterolateral wall side is forced to activate the peritricuspidal myocardium only clockwise.

Post-procedure increased trans-isthmus interval as measured from the pacing stimuli on coronary sinus electrode 9/10 (144 ms) to the atrial electrogram detected by electrode 1/2 on the Halo catheter The electrical impulse is forced to activate the atrial peritricuspidal myocardium only counterclockwise. Post-procedure increased trans-isthmus interval as measured from HALO electrode (140 ms). The electrical impulse provided by the posterolateral wall side is forced to activate the peritricuspidal myocardium only clockwise. The procedure was completed without complications. Six months later, the ambulatory interrogation of the device did not reveal any recurrent atrial arrhythmias; so no long-term anticoagulation therapy was necessary.

Discussion

Cardiac involvement in DM1 patients occurs as a degenerative process with progressive fibrosis and fatty replacement of the myocardium, not limited to the specialized conduction system, but involving also areas – initially unaffected – of the atrial myocardium (8). This anatomopathological substrate, causing the discontinuous and inhomogeneous propagation of sinus impulses and the prolongation of atrial conduction time, may facilitate the onset and the perpetuation of atrial arrhythmias in DM1 patients (9-12), as usually it happens in other clinical conditions (13-18). The modern pacemakers, including detailed diagnostic functions and therapeutic algorithms, may facilitate the diagnosis and management of frequent paroxysmal atrial tachy-arrhythmias that may remain undetected during conventional clinical follow-up (19-29). Radiofrequency ablation of typical atrial flutter is a very successful procedure with reported acute success rates of 90-95%. The conventional ablation technique requires creation of a complete line of conduction block across CTI, from the tricuspid valve to the inferior vena cava. Such an approach has a high overall success rate but results in variable, sometimes lengthy procedure times, mainly due to anatomic variation (30-35). The "maximum voltage-guided" (MVG) ablation technique targets high-voltage isthmus electrograms to ablate the functionally important anatomic muscle bundles alone, without drawing a complete anatomic line. Previous reports suggest that this method reduces the mean ablation time and shortens the procedure duration (36, 37). The ablation tip of IntellaTip MiFi catheter may enhance the available data for such a signal dependent technique. In this catheter, bipolar signals can be recorded between the three 0.8 mm-wide electrodes that are arranged radially 1.3 mm from the end of the catheter, alongside the standard distal and proximal bipolar recordings. The use of the Intellatip MiFi radiofrequency ablation catheter has been suggested to improve mapping resolution with a more precise localization of the points with the highest amplitude, potentially allowing less but more effective RF application in less time, in a technique that relies on signal amplitude (38). These features make the maximum voltage guided cavo-tricuspid isthmus ablation using a novel catheter with three mini electrodes within the ablation tip (IntellaTip MiFi, Boston Scientific, Boston, MA) particularly suitable for efficacy and safety during the ablation procedure in DM1 patients with an higher potential risk of complications for the diffuse atrial fibrosis. This novel ablative approach is particularly useful in this category of patients for their inability to maintain for long time the supine position.

Conclusions

We showed a successful case of maximum voltageguided cavo-tricuspid isthmus ablation using a novel catheter with mini electrodes within the ablation tip in a myotonic dystrophy type 1 patient with typical atrial flutter episodes revealed by atrio-ventricular electrograms analysis during the routine pacemaker controls.
  38 in total

Review 1.  Myotonic dystrophy and the heart.

Authors:  G Pelargonio; A Dello Russo; T Sanna; G De Martino; F Bellocci
Journal:  Heart       Date:  2002-12       Impact factor: 5.994

2.  P-wave duration and dispersion in patients with Emery-Dreifuss muscular dystrophy.

Authors:  Vincenzo Russo; Anna Rago; Alberto Palladino; Andrea Antonio Papa; Federica Di Meo; Nadia Della Cioppa; Paolo Golino; Maria Giovanna Russo; Raffaele Calabrò; Luisa Politano; Gerardo Nigro
Journal:  J Investig Med       Date:  2011-10       Impact factor: 2.895

3.  Reduction in atrial flutter ablation time by targeting maximum voltage: results of a prospective randomized clinical trial.

Authors:  Lorne J Gula; Damian P Redfearn; George D Veenhuyzen; Andrew D Krahn; Raymond Yee; George J Klein; Allan C Skanes
Journal:  J Cardiovasc Electrophysiol       Date:  2009-06-22

4.  Early electrocardiographic evaluation of atrial fibrillation risk in beta-thalassemia major patients.

Authors:  Vincenzo Russo; Anna Rago; Bruno Pannone; Federica Di Meo; Andrea Antonio Papa; Maria Carolina Mayer; Anna Spasiano; Maria Giovanna Russo; Paolo Golino; Raffaele Calabrò; Gerardo Nigro
Journal:  Int J Hematol       Date:  2011-03-10       Impact factor: 2.490

5.  Atrial flutter or fibrillation is the most frequent and life-threatening arrhythmia in myotonic dystrophy.

Authors:  Béatrice Brembilla-Perrot; Jérôme Schwartz; Olivier Huttin; Zied Frikha; Jean Marc Sellal; Nicholas Sadoul; Hugues Blangy; Arnaud Olivier; Sarah Louis; Pierre Kaminsky
Journal:  Pacing Clin Electrophysiol       Date:  2013-10-09       Impact factor: 1.976

6.  The effect of atrial preference pacing on paroxysmal atrial fibrillation incidence in myotonic dystrophy type 1 patients: a prospective, randomized, single-bind cross-over study.

Authors:  Vincenzo Russo; Anna Rago; Luisa Politano; Nadia Della Cioppa; Maria Giovanna Russo; Paolo Golino; Raffaele Calabrò; Gerardo Nigro
Journal:  Europace       Date:  2011-12-01       Impact factor: 5.214

7.  Atrial Septal Aneurysms and Supraventricular Arrhythmias: The Role of Atrial Electromechanical Delay.

Authors:  Vincenzo Russo; Anna Rago; Federica Di Meo; Andrea Antonio Papa; Carmine Ciardiello; Anna Cristiano; Raffaele Calabrò; Maria Giovanna Russo; Gerardo Nigro
Journal:  Echocardiography       Date:  2015-03-03       Impact factor: 1.724

8.  Risk of arrhythmias in myotonic dystrophy: trial design of the RAMYD study.

Authors:  Antonio Dello Russo; Fortunato Mangiola; Paolo Della Bella; Giovanni Nigro; Paola Melacini; Maria Grazia Bongiorni; Claudio Tondo; Leonardo Calò; Loredana Messano; Manuela Pace; Gemma Pelargonio; Michela Casella; Tommaso Sanna; Gabriella Silvestri; Anna Modoni; Elisabetta Zachara; Massimo Moltrasio; Lucia Morandi; Gerardo Nigro; Luisa Politano; Alberto Palladino; Fulvio Bellocci
Journal:  J Cardiovasc Med (Hagerstown)       Date:  2009-01       Impact factor: 2.160

9.  Ventricular fibrillation induced by coagulating mode bipolar electrocautery during pacemaker implantation in Myotonic Dystrophy type 1 patient.

Authors:  Vincenzo Russo; Anna Rago; Federica DI Meo; Nadia Della Cioppa; Andrea Antonio Papa; Maria Giovanna Russo; Gerardo Nigro
Journal:  Acta Myol       Date:  2014-12

10.  Atrial Fibrillation and Beta Thalassemia Major: The Predictive Role of the 12-lead Electrocardiogram Analysis.

Authors:  Vincenzo Russo; Anna Rago; Bruno Pannone; Andrea Antonio Papa; Maria Carolina Mayer; Anna Spasiano; Raffaele Calabro; Maria Giovanna Russo; Nigro Gerardo
Journal:  Indian Pacing Electrophysiol J       Date:  2014-05-25
View more
  2 in total

1.  Usefulness of the external loop recorder in a patient with Myotonic Dystrophy type 1 and recurrent episodes of palpitations: evaluation of the follow-up from diagnosis to 6 month-post-cardiac interventional treatment.

Authors:  Anna Rago; Andrea Antonio Papa; Dario Galante; Antonio Cassese; Paolo Golino
Journal:  Acta Myol       Date:  2018-05-01

2.  Myotonic dystrophy type 1 and pulmonary embolism: successful thrombus resolution with dabigatran etexilate therapy.

Authors:  Emanuele Gallinoro; Andrea Antonio Papa; Anna Rago; Simona Sperlongano; Antonio Cassese; Nadia Della Cioppa; Maria Cristina Giada Magliocca; Giovanni Cimmino; Paolo Golino
Journal:  Acta Myol       Date:  2018-09-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.