Comparative analysis of iterative reconstruction algorithms with resolution recovery and new solid state cameras dedicated to myocardial perfusion imaging.

Marco Brambilla1, Michela Lecchi2, Roberta Matheoud3, Lucia Leva4, Giovanni Lucignani5, Claudio Marcassa6, Orazio Zoccarato6.   

Abstract

New technologies are available in myocardial perfusion imaging. They include new software that recovers image resolution and limits image noise, multifocal collimators and dedicated cardiac cameras in which solid-state detectors are used and all available detectors are constrained to imaging just the cardiac field of view. These innovations resulted in shortened study times or reduced administered activity to patients, while preserving image quality. Many single center and some multicenter studies have been published during the introduction of these innovations in the clinical practice. Most of these studies were lead in the framework of "agreement studies" between different methods of clinical measurement. They aimed to demonstrate that these new software/hardware solutions allow the acquisition of images with reduced acquisition time or administered activity with comparable results (as for image quality, image interpretation, perfusion defect quantification, left ventricular volumes and ejection fraction) to the standard-time or standard-dose SPECT acquired with a conventional gamma camera and reconstructed with the traditional FBP method, considered as the gold standard. The purpose of this review is to provide the reader with a comprehensive understanding of the pro and cons of the different approaches summarizing the achievements reached so far and the issues that need further investigations.
Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cadmium-zincum-telluride; Iterative reconstruction; Myocardial perfusion imaging; Resolution recovery; SPECT

Mesh:

Year:  2017        PMID: 28343906     DOI: 10.1016/j.ejmp.2017.03.008

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  1 in total

1.  Image quality characteristics of myocardial perfusion SPECT imaging using state-of-the-art commercial software algorithms: evaluation of 10 reconstruction methods.

Authors:  Taher Hosny; Magdy M Khalil; Abdo A Elfiky; Wael M Elshemey
Journal:  Am J Nucl Med Mol Imaging       Date:  2020-12-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.