Literature DB >> 28341965

Reliability of a laryngo-pharyngeal esthesiometer and a method for measuring laryngo-pharyngeal mechano-sensitivity in a prospectively recruited cohort of patients.

Luis F Giraldo-Cadavid1,2,3, Javier Burguete4, Felipe Rueda5, Ana M Galvis6, Natalia Castaneda5, Luis M Agudelo-Otalora7, William D Moscoso7, Nelson Paez8, Secundino Fernandez9.   

Abstract

BACKGROUND: There are not reliable methods for measuring laryngo-pharyngeal mechano-sensitivity (LPMS). We aimed to determine the reliability of a new method for measuring LPMS using a new laryngo-pharyngeal esthesiometer (LPEER) in a prospective cohort of dysphagic stroke and non-dysphagic patients. The patients underwent clinical and endoscopic evaluations of swallowing (FESSST). The LPMS assessments consisted of measurements by an expert and a novel rater of the laryngeal-adductor reflex threshold (LART), cough reflex threshold (CRT) and gag reflex threshold (GRT) using the LPEER. We assessed the Bland-Altman limits of agreement, the intraclass correlation coefficients (ICCs) and Spearman correlation coefficients (SCCs). For the inter-rater comparisons, we contrasted the expert and novel raters. A total of 1608 measurements were obtained from 34 dysphagic stroke patients and 33 non-dysphagic patients. The intra-rater ICCs for all reflex thresholds were >0.90. The inter-rater ICCs were 0.87 for the LART, 0.79 for the CRT and 0.70 for the GRT. The intra-rater SCCs for all reflex thresholds were above 0.88 (P < 0.0001). The inter-rater SCC were 0.80 for the LART, 0.79 for the CRT and 0.70 for the GRT (all P < 0.0001). The Bland-Altman plots revealed good agreement for the LART and CRT and moderate agreement for the GRT. The median normal value was 0.14 mN for the LART, 4.4 mN for the CRT and 11.9 mN for the GRT. The median thresholds values in patients with aspiration were LART: 1.31 mN; CRT: 32.9 mN and GRT: 32.9 mN (all P < 0.006 vs normal thresholds). The LPEER exhibited substantial to excellent intra- and inter-rater reliability.

Entities:  

Keywords:  Bronchoscopy; Endoscopes; Larynx; Reliability; Sensory thresholds

Mesh:

Year:  2017        PMID: 28341965     DOI: 10.1007/s00405-017-4536-5

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  47 in total

1.  Interobserver agreement for the assessment of handicap in stroke patients.

Authors:  J C van Swieten; P J Koudstaal; M C Visser; H J Schouten; J van Gijn
Journal:  Stroke       Date:  1988-05       Impact factor: 7.914

2.  Correlation between laryngeal sensitivity and penetration/aspiration after stroke.

Authors:  Suely Mayumi Motonaga Onofri; Paula Cristina Cola; Larissa Cristina Berti; Roberta Gonçalves da Silva; Roberto Oliveira Dantas
Journal:  Dysphagia       Date:  2014-01-21       Impact factor: 3.438

3.  Relationship between self-reported odor intolerance and sensitivity to inhaled capsaicin: proposed definition of airway sensory hyperreactivity and estimation of its prevalence.

Authors:  Ake Johansson; Eva Millqvist; Steven Nordin; Mats Bende
Journal:  Chest       Date:  2006-06       Impact factor: 9.410

4.  Laryngeal and velopharyngeal sensory impairment in obstructive sleep apnea.

Authors:  Anh Tu Duy Nguyen; Vincent Jobin; Richard Payne; Josée Beauregard; Naftaly Naor; R John Kimoff
Journal:  Sleep       Date:  2005-05       Impact factor: 5.849

5.  Effects of enhanced bolus flavors on oropharyngeal swallow in patients treated for head and neck cancer.

Authors:  Barbara Roa Pauloski; Jerilyn A Logemann; Alfred W Rademaker; Donna Lundy; Paula A Sullivan; Lisa A Newman; Cathy Lazarus; Mary Bacon
Journal:  Head Neck       Date:  2012-08-21       Impact factor: 3.147

6.  Design of a new somatosensory stimulus delivery device for measuring laryngeal mechanosensory detection thresholds in humans.

Authors:  Michael J Hammer
Journal:  IEEE Trans Biomed Eng       Date:  2008-10-31       Impact factor: 4.538

7.  Predicting aspiration in patients with ischemic stroke: comparison of clinical signs and aerodynamic measures of voluntary cough.

Authors:  Carol A Smith Hammond; Larry B Goldstein; Ron D Horner; Jun Ying; Linda Gray; Leslie Gonzalez-Rothi; Donald C Bolser
Journal:  Chest       Date:  2008-11-18       Impact factor: 9.410

8.  Assessing penetration and aspiration: how do videofluoroscopy and fiberoptic endoscopic evaluation of swallowing compare?

Authors:  Annette M Kelly; Michael J Drinnan; Paula Leslie
Journal:  Laryngoscope       Date:  2007-10       Impact factor: 3.325

9.  Effect of surface sensory and motor electrical stimulation on chronic poststroke oropharyngeal dysfunction.

Authors:  L Rofes; V Arreola; I López; A Martin; M Sebastián; A Ciurana; P Clavé
Journal:  Neurogastroenterol Motil       Date:  2013-08-12       Impact factor: 3.598

Review 10.  Surface electrical stimulation for treating swallowing disorders after stroke: a review of the stimulation intensity levels and the electrode placements.

Authors:  Marziyeh Poorjavad; Saeed Talebian Moghadam; Noureddin Nakhostin Ansari; Mostafa Daemi
Journal:  Stroke Res Treat       Date:  2014-04-02
View more
  4 in total

1.  Accuracy of a Laryngopharyngeal Endoscopic Esthesiometer (LPEER) for Evaluating Laryngopharyngeal Mechanosensitivity: A Validation Study in a Prospectively Recruited Cohort of Patients.

Authors:  Luis F Giraldo-Cadavid; Javier Burguete; Felipe Rueda; Ana M Galvis; Natalia Castaneda; Mario Arbulu; Jorge I Balaguera; Nelson Paez; Secundino Fernandez
Journal:  Dysphagia       Date:  2017-07-27       Impact factor: 3.438

2.  Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study.

Authors:  Luis Fernando Giraldo-Cadavid; Alirio Rodrigo Bastidas; Diana Marcela Padilla-Ortiz; Diana Carolina Concha-Galan; María Angelica Bazurto; Leslie Vargas
Journal:  BMJ Open       Date:  2017-08-21       Impact factor: 2.692

3.  Aspiration in the Fiberoptic Endoscopic Evaluation of Swallowing Associated with an Increased Risk of Mortality in a Cohort of Patients Suspected of Oropharyngeal Dysphagia.

Authors:  Luis F Giraldo-Cadavid; Jaime A Pantoja; Yency J Forero; Hilda M Gutiérrez; Alirio R Bastidas
Journal:  Dysphagia       Date:  2019-07-20       Impact factor: 3.438

4.  Evaluation methods and influencing factors of cough sensitivity.

Authors:  Hao Mei; Wenhua Gu; Linxin Ran; Siwan Wen; Li Yu; Xianghuai Xu
Journal:  Ther Adv Respir Dis       Date:  2022 Jan-Dec       Impact factor: 4.031

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.