Literature DB >> 28341867

A safe procedure for connecting a continuous renal replacement therapy device into an extracorporeal membrane oxygenation circuit.

Natsumi Suga1, Yosuke Matsumura2, Ryuzo Abe1, Noriyuki Hattori1, Taka-Aki Nakada3, Shigeto Oda1.   

Abstract

Patients receiving extracorporeal membrane oxygenation (ECMO) often require continuous renal replacement therapy (CRRT). The intra-circuit pressure of adult ECMO usually deviates from the physiological range. We investigated the use of CRRT connected to an ECMO circuit with physiological intra-circuit pressures (0-150 mmHg, defined as the "safety range") using an in vitro experiment involving a water-filled ECMO circuit. The intra-circuit pressure pre-pump, post-pump, and post-oxygenator were measured while varying the height of the pump or ECMO flow. The bypass conduit pressure and distance from the post-oxygenator port were measured to find the "safety point", where the bypass pressure remained within the safety range. Both drainage and return limbs of the CRRT machine were connected to the safety point and the inlet and outlet pressures of the hemofilter were recorded while varying the ECMO and CRRT flow. The pre-pump pressure only remained within the safety range for heights >75 cm (ECMO flow = 4 L/min) or ECMO flow <3.5 L min (height = 50 cm). The post-pump and post-oxygenator pressure was generally outside of the safety range. The bypass pressure decreased according to the distance from the post-oxygenator port and the safety point was found at 60 or 75 cm (in a 90-cm length conduit) regardless of ECMO flow. The hemofilter inlet and outlet pressures remained within the safety range for all conditions of ECMO and CRRT flow, findings validated in clinical cases. The bypass conduit within an ECMO circuit can be connected to a CRRT machine safely under physiological pressures in adult patients receiving ECMO.

Entities:  

Keywords:  Adult; Bypass conduit; Continuous renal replacement therapy; Extracorporeal membrane oxygenation; Pressure

Mesh:

Year:  2017        PMID: 28341867     DOI: 10.1007/s10047-017-0952-y

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  14 in total

Review 1.  Contemporary extracorporeal membrane oxygenation for adult respiratory failure: life support in the new era.

Authors:  Graeme MacLaren; Alain Combes; Robert H Bartlett
Journal:  Intensive Care Med       Date:  2011-12-07       Impact factor: 17.440

2.  RIFLE classification is predictive of short-term prognosis in critically ill patients with acute renal failure supported by extracorporeal membrane oxygenation.

Authors:  Chan-Yu Lin; Yung-Chang Chen; Feng-Chun Tsai; Ya-Chung Tian; Chang-Chyi Jenq; Ji-Tseng Fang; Chin-Wei Yang
Journal:  Nephrol Dial Transplant       Date:  2006-06-24       Impact factor: 5.992

3.  How to perform a haemodialysis using the arterial and venous lines of an extracorporeal life support.

Authors:  Sylvain Rubin; Anne Poncet; Alain Wynckel; Bernard Baehrel
Journal:  Eur J Cardiothorac Surg       Date:  2009-11-13       Impact factor: 4.191

Review 4.  Renal replacement therapy in critically ill patients receiving extracorporeal membrane oxygenation.

Authors:  David J Askenazi; David T Selewski; Matthew L Paden; David S Cooper; Brian C Bridges; Michael Zappitelli; Geoffrey M Fleming
Journal:  Clin J Am Soc Nephrol       Date:  2012-04-12       Impact factor: 8.237

5.  Design and validation of a diaphragm pump for pediatric CRRT during ECMO.

Authors:  Arvind Santhanakrishnan; Trent Nestle; Brian L Moore; Ajit P Yoganathan; Matthew L Paden
Journal:  Int J Artif Organs       Date:  2013-12-12       Impact factor: 1.595

6.  Acute renal failure during extracorporeal support in the pediatric cardiac patient.

Authors:  Andrew H Smith; Daphne C Hardison; Christy R Worden; Geoffrey M Fleming; Mary B Taylor
Journal:  ASAIO J       Date:  2009 Jul-Aug       Impact factor: 2.872

Review 7.  Continuous renal replacement therapy during extracorporeal membrane oxygenation in patients treated in medical intensive care unit: technical considerations.

Authors:  Bożena Seczyńska; Wiesław Królikowski; Ilona Nowak; Miłosz Jankowski; Konstanty Szułdrzyński; Wojciech Szczeklik
Journal:  Ther Apher Dial       Date:  2014-09-04       Impact factor: 1.762

8.  Effect of age on the association between waist-to-height ratio and incidence of cardiovascular disease: the Suita study.

Authors:  Yukako Tatsumi; Makoto Watanabe; Yoshihiro Kokubo; Kunihiro Nishimura; Aya Higashiyama; Tomonori Okamura; Akira Okayama; Yoshihiro Miyamoto
Journal:  J Epidemiol       Date:  2013-06-29       Impact factor: 3.211

9.  Factors associated with outcomes of patients on extracorporeal membrane oxygenation support: a 5-year cohort study.

Authors:  Cecile Aubron; Allen C Cheng; David Pilcher; Tim Leong; Geoff Magrin; D Jamie Cooper; Carlos Scheinkestel; Vince Pellegrino
Journal:  Crit Care       Date:  2013-04-18       Impact factor: 9.097

Review 10.  Combination of extracorporeal membrane oxygenation and continuous renal replacement therapy in critically ill patients: a systematic review.

Authors:  Han Chen; Rong-Guo Yu; Ning-Ning Yin; Jian-Xin Zhou
Journal:  Crit Care       Date:  2014-12-08       Impact factor: 9.097

View more
  3 in total

Review 1.  Changes in acute blood purification therapy in critical care: republication of the article published in the Japanese Journal of Artificial Organs.

Authors:  Taka-Aki Nakada; Shigeto Oda; Ryuzo Abe; Noriyuki Hattori
Journal:  J Artif Organs       Date:  2019-06-24       Impact factor: 1.731

2.  Using additional pressure control lines when connecting a continuous renal replacement therapy device to an extracorporeal membrane oxygenation circuit.

Authors:  Soo Jin Na; Hee Jung Choi; Chi Ryang Chung; Yang Hyun Cho; Hye Ryoun Jang; Gee Young Suh; Kyeongman Jeon
Journal:  BMC Nephrol       Date:  2018-12-19       Impact factor: 2.388

Review 3.  Journal of Artificial Organs 2017: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; G Matsumiya; K Matsuda; E Tatsumi; T Abe; K Fukunaga; S Ichiba; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2018-02-09       Impact factor: 1.731

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.