Literature DB >> 28340770

A novel polyaniline/polypyrrole/graphene oxide fiber for the determination of volatile organic compounds in headspace gas of lung cell lines.

JingHong Li1, Hui Xu2.   

Abstract

Exploration of volatile organic compounds (VOCs) generated by lung cell lines is a powerful and non-invasive tool for the detection of potential volatile biomarkers of lung cancer. In this study, a simple and sensitive solid phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method was developed for the determination of VOCs in the headspace gas of lung cell lines. For the purpose of preconcentration, a novel polyaniline/polypyrrole/graphene oxide (PANI/PPy/GO) coating was prepared on the surface of stainless steel fiber via in-situ electrochemical deposition for the first time. The characteristic properties of the coating were studied and the results revealed that the coating possessed large surface area, high extraction efficiency, excellent thermal and mechanical stability as well as long lifespan. Some parameters affecting the extraction efficiency such as synthesis conditions, extraction and desorption conditions were optimized. Under the optimal conditions, the method displayed relatively wide linear range (three or four orders of magnitude) with correlation coefficients above 0.9916. Low detection limits from 1.0 to 12ngL-1 were obtained. Relative standard deviations ranged from 1.2% to 18.0% indicating good repeatability and reproducibility of the method. This method has been successfully applied to analyze VOCs in the headspace gas of lung adenocarcinoma epithelial cell line (A549) and human embryonic fibroblast cell line (MRC-5).
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Conducting polymer; Gas chromatography-mass spectrometry; Graphene oxide; Lung cell lines; Solid phase microextraction; Volatile organic compounds

Mesh:

Substances:

Year:  2017        PMID: 28340770     DOI: 10.1016/j.talanta.2017.03.005

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  A silica fiber coated with a ZnO-graphene oxide nanocomposite with high specific surface for use in solid phase microextraction of the antiepileptic drugs diazepam and oxazepam.

Authors:  Reza Alizadeh; Maryam Salami; Shahram Seidi
Journal:  Mikrochim Acta       Date:  2018-06-02       Impact factor: 5.833

2.  The use of solid phase microextraction for metabolomic analysis of non-small cell lung carcinoma cell line (A549) after administration of combretastatin A4.

Authors:  Karol Jaroch; Ezel Boyaci; Janusz Pawliszyn; Barbara Bojko
Journal:  Sci Rep       Date:  2019-01-23       Impact factor: 4.379

3.  High-efficiency solid-phase microextraction performance of polypyrrole enhanced titania nanoparticles for sensitive determination of polar chlorophenols and triclosan in environmental water samples.

Authors:  Mingguang Ma; Yunxia Wei; Huijuan Wei; Xianyu Liu; Haixia Liu
Journal:  RSC Adv       Date:  2021-08-25       Impact factor: 4.036

Review 4.  Green Approaches to Sample Preparation Based on Extraction Techniques.

Authors:  Alshymaa A Aly; Tadeusz Górecki
Journal:  Molecules       Date:  2020-04-09       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.