An electrochemical sensor device for measuring blood ammonia at the point of care.

N T Brannelly1, A J Killard2.   

Abstract

The level of ammonia in blood is relevant in a number of medical conditions. While ammonia is a marker of dysfunction, elevated ammonia is itself a serious medical emergency and can lead to significant and permanent neurological impairment if not addressed quickly. Blood ammonia testing is typically performed in the central laboratory. While a number of point of care devices have been developed, these are based on classical enzymatic or colorimetric principles and have not been widely adopted. In this work, an electrochemical sensor device was developed for measuring blood ammonia. The device was based on the deposition of polyaniline nanoparticle films onto screen printed interdigitated electrodes using inkjet printing and their integration into a polymer microfabricated device with a polytetrafluoroethylene membrane. The device required a 52µL serum sample and measured the change in impedance of the sensor with respect to air at 1kHz, 5mV rms. The device was capable of the measurement of ammonia in serum across the physiologically relevant range of 25-200µM (r2 =0.9984) and had a limit of detection of 12µM (n =3). The device showed no significant issues with common electrochemical interferences in blood. The device was also validated against a commercial spectrophotometric assay which resulted in excellent correlation (r =0.9699, p<0.0001) between both methods (n =3). When stored under desiccation, devices displayed minimal variation over time (0.64%) with respect to their impedance in air (n =12) and could be stored in desiccant for at least five months.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ammonia; Blood; Electrochemical; Point-of-care; Sensor

Mesh:

Substances:

Year:  2017        PMID: 28340723     DOI: 10.1016/j.talanta.2017.02.025

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

Review 1.  Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases.

Authors:  Antonio Tricoli; Giovanni Neri
Journal:  Sensors (Basel)       Date:  2018-03-22       Impact factor: 3.576

2.  A New Analytical Method to Quantify Ammonia in Freshwater with a Bulk Acoustic Wave Sensor.

Authors:  Vera Lúcia M Antunes; Maria Teresa S R Gomes
Journal:  Sensors (Basel)       Date:  2022-02-16       Impact factor: 3.576

3.  Development of the PANI/MWCNT Nanocomposite-Based Fluorescent Sensor for Selective Detection of Aqueous Ammonia.

Authors:  Debasis Maity; Mathankumar Manoharan; Ramasamy Thangavelu Rajendra Kumar
Journal:  ACS Omega       Date:  2020-04-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.