Sameh Talaat1,2, Ahmed Kaboudan3, Christoph Bourauel2, Nivine Ragy4, Katherine Kula5, Ahmed Ghoneima5,6. 1. Department of Orthodontics, College of Dentistry, Future University, Cairo, Egypt. 2. Oral Technology, University Hospital Bonn, Germany. 3. Department of Computer Science, ElShorouk Academy, New Caro, Egypt. 4. Department of Oral Medicine and Radiology, College of Dentistry, Future University, Cairo, Egypt. 5. Department of Orthodontics and Oral Facial Genetics, Indiana University School of Dentistry, Indianapolis, IN, USA. 6. Department of Orthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt.
Abstract
OBJECTIVE: To evaluate the validity and reliability of three-dimensional (3D) landmark-based palatal superimposition of digital dental models using Ortho Mechanics Sequential Analyzer (OMSA). METHODS: The sample consisted of pre- and post-treatment digital maxillary dental models of 20 orthodontic cases. For each case, the pre- and post-treatment digital models were superimposed using surface-based methods utilizing 3dMD Vultus and Invivo 5 software as well as a landmark-based method utilizing OMSA. The same set of parameters were measured on the superimposed 3D data by the three softwares for comparison. Agreement in the superimposition outcomes among the three superimposition methods was evaluated with intraclass correlation coefficients (ICCs), Bland-Altman plots, and repeated measures ANOVA. A P value of ≤ 0.05 was considered statistically significant. RESULTS: Repeatability was acceptable for all methods based on the ICCs. Agreement as measured by the ICCs and repeated measures ANOVA was high among the three methods. CONCLUSION: The results indicate that OMSA offers a valid and reliable tool for 3D landmark-based digital dental models superimposition using 3 points marked along the midpalatal raphe as reference.
OBJECTIVE: To evaluate the validity and reliability of three-dimensional (3D) landmark-based palatal superimposition of digital dental models using Ortho Mechanics Sequential Analyzer (OMSA). METHODS: The sample consisted of pre- and post-treatment digital maxillary dental models of 20 orthodontic cases. For each case, the pre- and post-treatment digital models were superimposed using surface-based methods utilizing 3dMD Vultus and Invivo 5 software as well as a landmark-based method utilizing OMSA. The same set of parameters were measured on the superimposed 3D data by the three softwares for comparison. Agreement in the superimposition outcomes among the three superimposition methods was evaluated with intraclass correlation coefficients (ICCs), Bland-Altman plots, and repeated measures ANOVA. A P value of ≤ 0.05 was considered statistically significant. RESULTS: Repeatability was acceptable for all methods based on the ICCs. Agreement as measured by the ICCs and repeated measures ANOVA was high among the three methods. CONCLUSION: The results indicate that OMSA offers a valid and reliable tool for 3D landmark-based digital dental models superimposition using 3 points marked along the midpalatal raphe as reference.
Authors: Daniela Garib; Felicia Miranda; Marilia S Yatabe; José Roberto Pereira Lauris; Camila Massaro; James A McNamara; Hera Kim-Berman; Guilherme Janson; Rolf G Behrents; Lucia H S Cevidanes; Antonio Carlos de Oliveira Ruellas Journal: Orthod Craniofac Res Date: 2019-04-01 Impact factor: 1.826