Literature DB >> 28339286

Advantages of Arthroscopic Rotator Cuff Repair With a Transosseous Suture Technique: A Prospective Randomized Controlled Trial.

Pietro Randelli1,2, Carlo Alberto Stoppani1, Carlo Zaolino1, Alessandra Menon1, Filippo Randelli1, Paolo Cabitza1,2.   

Abstract

BACKGROUND: Rotator cuff tear is a common finding in patients with painful, poorly functioning shoulders. The surgical management of this disorder has improved greatly and can now be fully arthroscopic.
PURPOSE: To evaluate clinical and radiological results of arthroscopic rotator cuff repair using 2 different techniques: single-row anchor fixation versus transosseous hardware-free suture repair. STUDY
DESIGN: Randomized controlled trial; Level of evidence, 1.
METHODS: Sixty-nine patients with rotator cuff tears were enrolled: 35 patients were operated with metal anchors and 34 with standardized transosseous repair. The patients were clinically evaluated before surgery, during the 28 days after surgery, and at least 1 year after the operation by the use of validated rating scores (Constant score, QuickDASH, and numerical rating scale [NRS]). Final follow-up was obtained at more than 3 years by a QuickDASH evaluation to detect any difference from the previous follow-up. During the follow-up, rotator cuff integrity was determined through magnetic resonance imaging and was classified according to the 5 Sugaya categories.
RESULTS: Patients operated with the transosseous technique had significantly less pain, especially from the 15th postoperative day: In the third week, the mean NRS value for the anchor group was 3.00 while that for transosseous group was 2.46 ( P = .02); in the fourth week, the values were 2.44 and 1.76, respectively ( P < .01). No differences in functional outcome were noted between the 2 groups at the final evaluation. In the evaluation of rotator cuff repair integrity, based on Sugaya magnetic resonance imaging classification, no significant difference was found between the 2 techniques in terms of retear rate ( P = .81).
CONCLUSION: No significant differences were found between the 2 arthroscopic repair techniques in terms of functional and radiological results. However, postoperative pain decreased more quickly after the transosseous procedure, which therefore emerges as a possible improvement in the surgical repair of the rotator cuff. Registration: NCT01815177 ( ClinicalTrials.gov identifier).

Entities:  

Keywords:  MRI evaluation; anchor repair; retear rate; rotator cuff; transosseous arthroscopic repair

Mesh:

Year:  2017        PMID: 28339286     DOI: 10.1177/0363546517695789

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  18 in total

Review 1.  [Arthroscopic rotator cuff surgery : New and established methods].

Authors:  S Pauly; M Scheibel
Journal:  Orthopade       Date:  2018-02       Impact factor: 1.087

2.  Comparison of the clinical and radiological outcomes of arthroscopic transosseous and transosseous-equivalent double-row rotator cuff repair techniques.

Authors:  Ahmet Fırat; Mustafa Aydın; Osman Tecimel; Ali Öçgüder; Yavuz Sanisoğlu; Mahmut Uğurlu
Journal:  Acta Orthop Traumatol Turc       Date:  2020-03       Impact factor: 1.511

3.  Transosseous repair with a cortical implant for greater tubercle cyst-related rotator cuff tear results in good clinical outcomes, but significant implant migration.

Authors:  Mustafa Aydın; Enejd Veizi; Şahin Çepni; Ali Şahin; Ahmet Fırat
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-04-02       Impact factor: 4.114

4.  Linked Double-Row Equivalent Arthroscopic Rotator Cuff Repair Leads to Significantly Improved Patient Outcomes.

Authors:  Atsushi Endo; Paul Hoogervorst; Conrad Safranek; Kyle R Sochacki; Marc R Safran; Seth L Sherman; Joseph Donahue
Journal:  Orthop J Sports Med       Date:  2020-07-16

5.  The Effect of Three Different Suture Anchors for Rotator Cuff Repair on Primary Cultures of Human Bone Marrow Mesenchymal Stem Cells.

Authors:  Gabriele Thiébat; Paolo Capitani; Laura de Girolamo; Carlotta Perucca Orfei; Francesca Facchini; Herbert Schoenhuber; Marco Viganò
Journal:  Joints       Date:  2018-06-14

6.  Epidemiological Analysis of Changes in Clinical Practice for Full-Thickness Rotator Cuff Tears From 2010 to 2015.

Authors:  Avinesh Agarwalla; Gregory L Cvetanovich; Anirudh K Gowd; Anthony A Romeo; Brian J Cole; Nikhil N Verma; Brian Forsythe
Journal:  Orthop J Sports Med       Date:  2019-05-28

7.  PROSPECT guideline for rotator cuff repair surgery: systematic review and procedure-specific postoperative pain management recommendations.

Authors:  O Toma; B Persoons; E Pogatzki-Zahn; M Van de Velde; G P Joshi
Journal:  Anaesthesia       Date:  2019-08-07       Impact factor: 6.955

8.  Arthroscopic, Needle-Based, Transosseous Rotator Cuff Repair.

Authors:  Ehud Atoun; Liam T Kane; Joseph A Abboud
Journal:  Arthrosc Tech       Date:  2019-12-18

9.  Rotator Cuff Repair Technique With Transosseous Knotless Anchor System.

Authors:  Michael M Murphy; Robert Z Tashjian; Robert T Burks
Journal:  Arthrosc Tech       Date:  2018-08-20

10.  Optimal Angle of the Bone Tunnel for Avoiding Axillary Nerve Injuries During Arthroscopic Transosseous Rotator Cuff Repair: A Magnetic Resonance Imaging-Based Simulation Study.

Authors:  Himanshu Gupta; Pallav Mishra; Himanshu Kataria; Vineet Jain; Amit Raj Tyagi; Harsh Mahajan; Ashish Datt Upadhyay
Journal:  Orthop J Sports Med       Date:  2018-11-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.