Literature DB >> 28338383

Intersession Reliability of Isokinetic Strength Testing in Knee and Elbow Extension and Flexion Using the BTE PrimusRS.

Alexander Törpel1, Tim Becker1, Angelina Thiers1, Dennis Hamacher1, Lutz Schega1.   

Abstract

CONTEXT: The use of isokinetic dynamometers playing an important role in different settings of sports and medicine. Therefore, a high reliability of these devices is required.
OBJECTIVE: The aim of this study was to examine the intersession reliability of the dynamometer BTE PrimusRS regarding to the isolated single-joint exercises extension/flexion of the knee and elbow for isokinetic testing
DESIGN: Intersession reliability.
SETTING: Clinical settings and sports science. PARTICIPANTS: 16 young male students. INTERVENTION: The testing protocol includes 5 consecutive repetitions (concentric/concentric) at a velocity of 60°/s for the exercises. MAIN OUTCOME MEASURES: Raw data of torque curves were used to determine the peak torque. Reliability was evaluated with the intraclass correlation coefficient (ICC), the limits of agreement (LoA), and the bias and the variability of measurements (V).
RESULTS: High ICC values (.954-.991) were found for the used exercises. However, the LoAs yielded up to over 16 Nm and the V yielded up to nearly 9 % in several testing exercises, indicating poor absolute reliability.
CONCLUSION: The BTE PrimusRS shows good to excellent reliability. However, regarding the absolute measures of reliability, the users must decide as experts in their fields whether this reliability is sufficient for their purposes.

Entities:  

Keywords:  therapy; single-joint exercise; torque; dynamometer

Mesh:

Year:  2017        PMID: 28338383     DOI: 10.1123/jsr.2016-0209

Source DB:  PubMed          Journal:  J Sport Rehabil        ISSN: 1056-6716            Impact factor:   1.931


  4 in total

1.  Application of ultrasound elastography in the evaluation of muscle strength in a healthy population.

Authors:  Xinyi Tang; Liyun Wang; Ruiqian Guo; Songya Huang; Yuanjiao Tang; Li Qiu
Journal:  Quant Imaging Med Surg       Date:  2020-10

2.  A Portable Wearable Inertial System for Rehabilitation Monitoring and Evaluation of Patients With Total Knee Replacement.

Authors:  Nan Lou; Yanan Diao; Qiangqiang Chen; Yunkun Ning; Gaoqiang Li; Shengyun Liang; Guanglin Li; Guoru Zhao
Journal:  Front Neurorobot       Date:  2022-03-23       Impact factor: 2.650

3.  Concentric and Eccentric Force Changes with Elastic Band and Isotonic Heavy Resistance Training: A Randomized Controlled Trial.

Authors:  Eric Folkins; Sidharth Sahni; John Ryan; Stacey Wooden; Gina Bushby; Christian Radzinski
Journal:  Int J Sports Phys Ther       Date:  2021-06-02

4.  Effect of Resistance Training Under Normobaric Hypoxia on Physical Performance, Hematological Parameters, and Body Composition in Young and Older People.

Authors:  Alexander Törpel; Beate Peter; Lutz Schega
Journal:  Front Physiol       Date:  2020-04-28       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.