Literature DB >> 28336189

3D CAD/reverse engineering technique for assessment of Thai morphology: Proximal femur and acetabulum.

Nattapon Chantarapanich1, Sattaya Rojanasthien2, Bancha Chernchujit3, Banchong Mahaisavariya4, Kavin Karunratanakul5, Prasert Chalermkarnnon5, Chinnawit Glunrawd5, Kriskrai Sitthiseripratip6.   

Abstract

PURPOSE: To assess morphological parameters of proximal femur and acetabulum in Thai population with three-dimensional measurement technique, and to analysis of collateral side symmetric, gender difference, and correlation between morphometric parameters.
METHODS: Investigation was performed in 240 femurs. All three-dimensional femur models were acquitted from 64-slice spiral CT scanner. Morphometric parameters under consideration included acetabular diameter, femoral head diameter, shaft isthmus location, intramedullary canal diameter, diaphyseal diameter, femoral head height, femoral neck isthmus, femoral neck length, neck shaft angle, bow angle, and anteversion angle. All parameters were measured based on functions and least-square regression function in CAD software. Obtained measured data were then used for analysis of collateral side symmetric, gender difference, correlation between morphometric parameters, and compared with other populations.
RESULTS: Female had a smaller dimension compared with male in most of the parameters. No significant difference was observed between left and right femurs. High correlation pairs of morphometric parameters included femoral head diameter-acetabular diameter, femoral head diameter-neck isthmus diameter, femoral head diameter-diaphyseal diameter at shaft isthmus level, acetabular diameter-neck isthmus diameter, neck isthmus diameter-diaphyseal diameter at shaft isthmus level, and acetabular diameter-diaphyseal diameter at shaft isthmus level. Some morphometric parameters of Thai are smaller than other Caucasian, and some Asian nation, i.e. femoral head diameter, femoral neck length, and femoral head height.
CONCLUSIONS: This study provides essential morphometric data for various orthopedic implant designs relating to proximal femur region.
Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

Mesh:

Year:  2017        PMID: 28336189     DOI: 10.1016/j.jos.2017.02.003

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  4 in total

1.  Single lag screw and reverse distal femur locking compression plate for concurrent cervicotrochanteric and shaft fractures of the femur: biomechanical study validated with a clinical series.

Authors:  Surasak Jitprapaikulsarn; Nattapon Chantarapanich; Arthit Gromprasit; Chantas Mahaisavariya; Chawanan Patamamongkonchai
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-01-08

2.  Morphometric measurement of the proximal tibia to design the tibial component of total knee arthroplasty for the Thai population.

Authors:  Chotchuang Phombut; Supakit Rooppakhun; Bura Sindhupakorn
Journal:  J Exp Orthop       Date:  2021-12-20

3.  A comparison between Asians and Caucasians in the dimensions of the femoral isthmus based on a 3D-CT analysis of 1189 adult femurs.

Authors:  Darius M Thiesen; Dimitris Ntalos; Alexander Korthaus; Andreas Petersik; Karl-Heinz Frosch; Maximilian J Hartel
Journal:  Eur J Trauma Emerg Surg       Date:  2021-07-28       Impact factor: 2.374

4.  Volume fusion of CT images to measure femoral symmetricity.

Authors:  Peyman Bakhshayesh; Olof Sandberg; Vishal Kumar; Adam Ali; Anders Enocson
Journal:  Surg Radiol Anat       Date:  2019-11-28       Impact factor: 1.246

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.