Literature DB >> 28336153

Quantification and comparison of the mechanical properties of four human cardiac valves.

Thuy Pham1, Fatiesa Sulejmani1, Erica Shin1, Di Wang1, Wei Sun2.   

Abstract

OBJECTIVE: Although having the same ability to permit unidirectional flow within the heart, the four main valves-the mitral valve (MV), aortic (AV), tricuspid (TV) and pulmonary (PV) valves-experience different loading conditions; thus, they exhibit different structural integrity from one another. Most research on heart valve mechanics have been conducted mainly on MV and AV or an individual valve, but none quantify and compare the mechanical and structural properties among the four valves from the same aged patient population whose death was unrelated to cardiovascular disease.
METHODS: A total of 114 valve leaflet samples were excised from 12 human cadavers whose death was unrelated to cardiovascular disease (70.1±3.7years old). Tissue mechanical and structural properties were characterized by planar biaxial mechanical testing and histological methods. The experimental data were then fitted with a Fung-type constitutive model.
RESULTS: The four valves differed substantially in thickness, degree of anisotropy, and stiffness. The leaflets of the left heart (the AV leaflets and the anterior mitral leaflets, AML) were significantly stiffer and less compliant than their counterparts in the right heart. TV leaflets were the most extensible and isotropic, while AML and AV leaflets were the least extensible and the most anisotropic. Age plays a significant role in the reduction of leaflet stiffness and extensibility with nearly straightened collagen fibers observed in the leaflet samples from elderly groups (65years and older).
CONCLUSIONS: Results from 114 human leaflet samples not only provided a baseline quantification of the mechanical properties of aged human cardiac valves, but also offered a better understanding of the age-dependent differences among the four valves. It is hoped that the experimental data collected and the associated constitutive models in this study can facilitate future studies of valve diseases, treatments and the development of interventional devices. STATEMENT OF SIGNIFICANCE: Most research on heart valve mechanics have been conducted mainly on mitral and aortic valves or an individual valve, but none quantify and compare the mechanical and structural properties among the four valves from the same relatively healthy elderly patient population. In this study, the mechanical and microstructural properties of 114 leaflets of aortic, mitral, pulmonary and tricuspid valves from 12 human cadaver hearts were mechanically tested, analyzed and compared. Our results not only provided a baseline quantification of the mechanical properties of aged human valves, but a age range between patients (51-87years) also offers a better understanding of the age-dependent differences among the four valves. It is hoped that the obtained experimental data and associated constitutive parameters can facilitate studies of valve diseases, treatments and the development of interventional devices.
Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aging; Heart valves; Mechanical properties; Pulmonary; Tricuspid

Mesh:

Year:  2017        PMID: 28336153     DOI: 10.1016/j.actbio.2017.03.026

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  26 in total

1.  A detailed mechanical and microstructural analysis of ovine tricuspid valve leaflets.

Authors:  William D Meador; Mrudang Mathur; Gabriella P Sugerman; Tomasz Jazwiec; Marcin Malinowski; Matthew R Bersi; Tomasz A Timek; Manuel K Rausch
Journal:  Acta Biomater       Date:  2019-11-22       Impact factor: 8.947

Review 2.  The time has come to extend the expiration limit of cryopreserved allograft heart valves.

Authors:  Jan Burkert; Petra Kochová; Zbyněk Tonar; Robert Cimrman; Tereza Blassová; Ramadan Jashari; Radovan Fiala; Jaroslav Špatenka
Journal:  Cell Tissue Bank       Date:  2020-06-24       Impact factor: 1.522

3.  Mechanical and structural analysis of the pulmonary valve in congenital heart defects: A presentation of two case studies.

Authors:  Fatiesa Sulejmani; Anastassia Pokutta-Paskaleva; Olga Salazar; Mohsen Karimi; Wei Sun
Journal:  J Mech Behav Biomed Mater       Date:  2018-08-31

4.  Finite Element Analysis of Tricuspid Valve Deformation from Multi-slice Computed Tomography Images.

Authors:  Fanwei Kong; Thuy Pham; Caitlin Martin; Raymond McKay; Charles Primiano; Sabet Hashim; Susheel Kodali; Wei Sun
Journal:  Ann Biomed Eng       Date:  2018-04-16       Impact factor: 3.934

5.  Tricuspid Valve Regurgitation Decreases after MitraClip Implantation: Fluid Structure Interaction Simulation.

Authors:  Yaghoub Dabiri; Jiang Yao; Kevin L Sack; Ghassan S Kassab; Julius M Guccione
Journal:  Mech Res Commun       Date:  2019-04-25       Impact factor: 2.254

Review 6.  Mechanical considerations for polymeric heart valve development: Biomechanics, materials, design and manufacturing.

Authors:  Richard L Li; Jonathan Russ; Costas Paschalides; Giovanni Ferrari; Haim Waisman; Jeffrey W Kysar; David Kalfa
Journal:  Biomaterials       Date:  2019-09-17       Impact factor: 12.479

7.  An investigation of layer-specific tissue biomechanics of porcine atrioventricular valve anterior leaflets.

Authors:  Katherine E Kramer; Colton J Ross; Devin W Laurence; Anju R Babu; Yi Wu; Rheal A Towner; Arshid Mir; Harold M Burkhart; Gerhard A Holzapfel; Chung-Hao Lee
Journal:  Acta Biomater       Date:  2019-06-29       Impact factor: 8.947

8.  Integration of polarized spatial frequency domain imaging (pSFDI) with a biaxial mechanical testing system for quantification of load-dependent collagen architecture in soft collagenous tissues.

Authors:  Samuel V Jett; Luke T Hudson; Ryan Baumwart; Bradley N Bohnstedt; Arshid Mir; Harold M Burkhart; Gerhard A Holzapfel; Yi Wu; Chung-Hao Lee
Journal:  Acta Biomater       Date:  2019-11-14       Impact factor: 8.947

9.  A pilot in silico modeling-based study of the pathological effects on the biomechanical function of tricuspid valves.

Authors:  Devin W Laurence; Emily L Johnson; Ming-Chen Hsu; Ryan Baumwart; Arshid Mir; Harold M Burkhart; Gerhard A Holzapfel; Yi Wu; Chung-Hao Lee
Journal:  Int J Numer Method Biomed Eng       Date:  2020-05-08       Impact factor: 2.747

10.  An investigation of the effect of freezing storage on the biaxial mechanical properties of excised porcine tricuspid valve anterior leaflets.

Authors:  Grace A Duginski; Colton J Ross; Devin W Laurence; Cortland H Johns; Chung-Hao Lee
Journal:  J Mech Behav Biomed Mater       Date:  2019-09-16