Literature DB >> 28334038

Correction: Beyond Pressure Gradients: The Effects of Intervention on Heart Power in Aortic Coarctation.

.   

Abstract

[This corrects the article DOI: 10.1371/journal.pone.0168487.].

Entities:  

Year:  2017        PMID: 28334038      PMCID: PMC5363949          DOI: 10.1371/journal.pone.0174838

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


Figs 2 and 3 are displayed incorrectly in the PDF. The publisher apologizes for these errors. The authors have provided the corrected Figs 2 and 3 here.
Fig 2

The assessment of a cardiac energy profile in patients with aortic coarctation.

In all evaluated study participants this profile was acquired before and after the interventional treatment procedure. AV Aortic valve, CoA coarctation of the aorta, EHP External heart power, Ea arterial load, Emax the slope of the end-systolic pressure-volume relationship, IHP Internal heart power. LV Left ventricle, PV-loops Pressure-Volume loops.

Fig 3

Main results.

(a) Internal heart power (IHP) before and after treatment divided into groups according to the initial IHP above and below 5 W (b) The change in IHP with treatment plotted against the change of catheter-measured pressure gradients in each patient (the start-point of each vector represents the state before treatment, whereas the end-point represents the state after treatment) (c) Power efficiency before and after treatment grouped according to the initial IHP. * statistically significant differences.

The assessment of a cardiac energy profile in patients with aortic coarctation.

In all evaluated study participants this profile was acquired before and after the interventional treatment procedure. AV Aortic valve, CoA coarctation of the aorta, EHP External heart power, Ea arterial load, Emax the slope of the end-systolic pressure-volume relationship, IHP Internal heart power. LV Left ventricle, PV-loops Pressure-Volume loops.

Main results.

(a) Internal heart power (IHP) before and after treatment divided into groups according to the initial IHP above and below 5 W (b) The change in IHP with treatment plotted against the change of catheter-measured pressure gradients in each patient (the start-point of each vector represents the state before treatment, whereas the end-point represents the state after treatment) (c) Power efficiency before and after treatment grouped according to the initial IHP. * statistically significant differences.
  1 in total

1.  Beyond Pressure Gradients: The Effects of Intervention on Heart Power in Aortic Coarctation.

Authors:  Joao Filipe Fernandes; Leonid Goubergrits; Jan Brüning; Florian Hellmeier; Sarah Nordmeyer; Tiago Ferreira da Silva; Stephan Schubert; Felix Berger; Titus Kuehne; Marcus Kelm
Journal:  PLoS One       Date:  2017-01-12       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.