Literature DB >> 28329125

Outcomes in Patients With Cardiovascular Implantable Electronic Device Infection Managed With Chronic Antibiotic Suppression.

Eugene M Tan1, Daniel C DeSimone1, M Rizwan Sohail1,2, Larry M Baddour1,2, Walter R Wilson1, James M Steckelberg1, Abinash Virk1.   

Abstract

BACKGROUND.: Most cardiovascular implantable electronic device (CIED) recipients are elderly, have multiple comorbid conditions, and are at increased risk of CIED infection (CIEDI). Current guidelines recommend complete device removal in patients with CIEDI to prevent relapse and mortality. However, comorbidities or other factors may preclude device removal, thus prompting a nonsurgical approach that includes chronic antibiotic suppression (CAS). There are limited data on outcomes of patients receiving CAS for CIEDI. METHODS.: We retrospectively screened 660 CIEDI cases from 2005 to 2015 using electronic health records and a CIEDI institutional database and identified 48 patients prescribed CAS. Primary outcomes were infection relapse and survival. RESULTS.: The median age was 78 years, and 73% (35/48) were male. The median Charlson comorbidity index was 4. Common pathogens were coagulase-negative staphylococci (21%, 10/48) and methicillin-sensitive Staphylococcus aureus (19%, 9/48). At 1 month after hospitalization, 25% (12/48) of patients had died, of whom only 1 initiated CAS; 67% (8/12) of these had staphylococcal infections. Of the 37 patients who initiated CAS, the most common antimicrobials were trimethoprim-sulfamethoxazole, penicillin, and amoxicillin (22%, 8/37 each). Estimated median overall survival was 1.43 years (95% confidence interval, 0.27-2.14), with 18% (6/33 survivors) developing relapse within 1 year. Of the 6 patients who relapsed, 2 (33%) subsequently underwent CIED extraction. CONCLUSION.: CAS is reasonable in select patients who are not candidates for complete device removal for attempted cure of CIEDI. Nevertheless, 1-month mortality in our sample of CAS-eligible patients was high and reflective of high rates of comorbid conditions.
© The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com

Entities:  

Keywords:  antibiotic; cardiovascular; device; suppression.

Mesh:

Substances:

Year:  2017        PMID: 28329125     DOI: 10.1093/cid/cix181

Source DB:  PubMed          Journal:  Clin Infect Dis        ISSN: 1058-4838            Impact factor:   9.079


  7 in total

1.  Long-term antibiotic therapy in patients with surgery-indicated not undergoing surgery infective endocarditis.

Authors:  Nuria Vallejo Camazon; Lourdes Mateu; Germán Cediel; Laura Escolà-Vergé; Nuria Fernández-Hidalgo; Mercedes Gurgui Ferrer; Maria Teresa Perez Rodriguez; Guillermo Cuervo; Raquel Nuñez Aragón; Cinta Llibre; Nieves Sopena; Maria Dolores Quesada; Elisabeth Berastegui; Albert Teis; Jorge Lopez Ayerbe; Gladys Juncà; Francisco Gual; Elena Ferrer Sistach; Ainhoa Vivero; Esteban Reynaga; Maria Hernández Pérez; Christian Muñoz Guijosa; Lluisa Pedro-Botet; Antoni Bayés-Genís
Journal:  Cardiol J       Date:  2021-05-25       Impact factor: 2.737

2.  Role of 18F-FDG PET/CT in the diagnosis of cardiovascular implantable electronic device infections: A meta-analysis.

Authors:  Maryam Mahmood; Ayse Tuba Kendi; Saira Farid; Saira Ajmal; Geoffrey B Johnson; Larry M Baddour; Panithaya Chareonthaitawee; Paul A Friedman; M Rizwan Sohail
Journal:  J Nucl Cardiol       Date:  2017-09-14       Impact factor: 5.952

3.  Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study.

Authors:  Sara Pichtchoulin; Ingrid Selmeryd; Elisabeth Freyhult; Pär Hedberg; Jonas Selmeryd
Journal:  Ups J Med Sci       Date:  2021-03-05       Impact factor: 2.384

Review 4.  Approach to Diagnosis of Cardiovascular Implantable-Electronic-Device Infection.

Authors:  Daniel C DeSimone; M Rizwan Sohail
Journal:  J Clin Microbiol       Date:  2018-06-25       Impact factor: 5.948

5.  A case of Brucella melitensis endocarditis in a patient with cardiovascular implantable electronic device.

Authors:  Wasl Al-Adsani; Ali Ahmad; Mohammad Al-Mousa
Journal:  Infect Drug Resist       Date:  2018-03-09       Impact factor: 4.003

6.  European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS).

Authors:  Carina Blomström-Lundqvist; Vassil Traykov; Paola Anna Erba; Haran Burri; Jens Cosedis Nielsen; Maria Grazia Bongiorni; Jeanne Poole; Giuseppe Boriani; Roberto Costa; Jean-Claude Deharo; Laurence M Epstein; Laszlo Saghy; Ulrika Snygg-Martin; Christoph Starck; Carlo Tascini; Neil Strathmore
Journal:  Europace       Date:  2020-04-01       Impact factor: 5.214

Review 7.  Cardiac Implantable Electronic Devices Infection Assessment, Diagnosis and Management: A Review of the Literature.

Authors:  Filippo Toriello; Massimo Saviano; Andrea Faggiano; Domitilla Gentile; Giovanni Provenzale; Alberto Vincenzo Pollina; Elisa Gherbesi; Lucia Barbieri; Stefano Carugo
Journal:  J Clin Med       Date:  2022-10-06       Impact factor: 4.964

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.