Sang Yoon Lee1, Jun Young Hong2, Je Hyeok Oh2, Sun-Han Son3. 1. Department of Rehabilitation Medicine, Seoul National University Boramae Medical Center. 2. Department of Emergency Medicine. 3. Department of Physical Medicine and Rehabilitation, College of Medicine, Chung-Ang University, Seoul, Republic of Korea.
Abstract
OBJECTIVES: The two-finger technique (TFT) using the index-middle fingers of the right hand (TFT-R23) was recently confirmed to produce deeper chest compression depth (CCD) compared with the TFT using any other fingers. This study was carried out to confirm whether the TFT-R23 would be as effective as the two-thumb technique (TTT). In addition, individual finger strengths were measured to identify the reasons why the TTT and TFT-R23 produced deeper CCD than any other methods. METHODS: This prospective randomized cross-over trial compared TTT with TFT-R23. A total of 37 doctors conducted 2 min single-rescuer cardiopulmonary resuscitation using TTT and TFT-R23 in a random order using a 3-month-old sized infant manikin laid on the floor. The chest compression to ventilation ratio was set to 15 : 2. In addition, finger strengths were measured using a pinch meter. RESULTS: The actual CCD of the TTT was significantly deeper than that of the TFT-R23 (41.3±1.3 vs. 39.8±1.5 mm, P<0.001). Although the hands-off time of the TTT was significantly longer than that of the TFT-R23 (55.6±5.7 vs. 53.6±5.8 s, P=0.002), the mean difference was only 2.0±3.7 s (95% confidence interval: 0.755-3.245). The finger strength of the TTT was significantly higher than that of TFT-R23 (23.8±10.1 vs. 13.7±5.1 kg, P<0.001). CONCLUSION: The TTT produced deeper CCD compared with that of the TFT-R23 because the finger strength of the TTT was significantly higher than that of the TFT-R23.
RCT Entities:
OBJECTIVES: The two-finger technique (TFT) using the index-middle fingers of the right hand (TFT-R23) was recently confirmed to produce deeper chest compression depth (CCD) compared with the TFT using any other fingers. This study was carried out to confirm whether the TFT-R23 would be as effective as the two-thumb technique (TTT). In addition, individual finger strengths were measured to identify the reasons why the TTT and TFT-R23 produced deeper CCD than any other methods. METHODS: This prospective randomized cross-over trial compared TTT with TFT-R23. A total of 37 doctors conducted 2 min single-rescuer cardiopulmonary resuscitation using TTT and TFT-R23 in a random order using a 3-month-old sized infant manikin laid on the floor. The chest compression to ventilation ratio was set to 15 : 2. In addition, finger strengths were measured using a pinch meter. RESULTS: The actual CCD of the TTT was significantly deeper than that of the TFT-R23 (41.3±1.3 vs. 39.8±1.5 mm, P<0.001). Although the hands-off time of the TTT was significantly longer than that of the TFT-R23 (55.6±5.7 vs. 53.6±5.8 s, P=0.002), the mean difference was only 2.0±3.7 s (95% confidence interval: 0.755-3.245). The finger strength of the TTT was significantly higher than that of TFT-R23 (23.8±10.1 vs. 13.7±5.1 kg, P<0.001). CONCLUSION: The TTT produced deeper CCD compared with that of the TFT-R23 because the finger strength of the TTT was significantly higher than that of the TFT-R23.
Authors: Chun-Yu Chang; Po-Chen Lin; Yung-Jiun Chien; Chien-Sheng Chen; Meng-Yu Wu Journal: Int J Environ Res Public Health Date: 2020-06-05 Impact factor: 3.390