Literature DB >> 28328524

Paramagnetic micro-particles as a tool for rapid quantification of apixaban, dabigatran, edoxaban and rivaroxaban in human plasma by UHPLC-MS/MS.

Martin H J Wiesen1, Cornelia Blaich1, Thomas Streichert1, Guido Michels1, Carsten Müller1.   

Abstract

BACKGROUND: Assessment of the anticoagulant activity of direct oral anticoagulants (DOACs) is justified in special clinical situations. Here, we evaluated two independent extraction methods and developed a multi-analyte ultra-high performance liquid chromatography tandem mass (UHPLC-MS/MS) method for the quantification of apixaban, dabigatran, edoxaban and rivaroxaban in human plasma.
METHODS: Routine extraction based on protein precipitation with acetonitrile and subsequent centrifugation was compared to sample clean-up using commercial paramagnetic micro-particles and subsequent magnetic depletion. Stable isotope-labeled analogs of all analytes were employed as internal standards. The method was validated according to international guidelines in terms of linearity, precision, trueness, sensitivity, recovery and matrix effects. The performances of both extraction methods were assessed in clinical samples obtained from patients treated with either apixaban or rivaroxaban. Additionally, we report on a patient with nonadherence to rivaroxaban treatment and fulminant pulmonary embolism.
RESULTS: The method was linear from 2 to 500 ng/mL for all analytes, and quantification of DOACs was established within a run time of 2.0 min. Based on MS/MS analyte responses, relative matrix effects were better controlled for dabigatran after extraction with paramagnetic micro-particles. Internal standards fully compensated for recovery and matrix effects in all assays, yielding equivalent results for both methods. Apixaban and rivaroxaban concentrations determined in clinical samples after extraction with both methods were in good agreement (R2=0.990).
CONCLUSIONS: A rapid and accurate multi-component UHPLC-MS/MS method for the quantification of four DOACs in human plasma was established. Paramagnetic micro-particles appear suitable for clean-up of plasma samples for LC-MS/MS-based therapeutic drug monitoring purposes.

Entities:  

Keywords:  LC-MS/MS; apixaban; dabigatran; edoxaban; magnetic beads; rivaroxaban

Mesh:

Substances:

Year:  2017        PMID: 28328524     DOI: 10.1515/cclm-2016-0888

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  3 in total

1.  Residual rivaroxaban exposure after discontinuation of anticoagulant therapy in patients undergoing cardiac catheterization.

Authors:  Martin H J Wiesen; Cornelia Blaich; Max Taubert; Veronika Jennissen; Thomas Streichert; Roman Pfister; Guido Michels
Journal:  Eur J Clin Pharmacol       Date:  2018-01-28       Impact factor: 2.953

2.  Quantification of apixaban in human plasma using ultra performance liquid chromatography coupled with tandem mass spectrometry.

Authors:  Hyeon-Cheol Jeong; Tae-Eun Kim; Kwang-Hee Shin
Journal:  Transl Clin Pharmacol       Date:  2019-03-27

3.  Rapid Assay for the Therapeutic Drug Monitoring of Edoxaban.

Authors:  Md Abdur Rashid; Saiqa Muneer; Yahya Alhamhoom; Nazrul Islam
Journal:  Biomolecules       Date:  2022-04-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.