Alternative mass reference standards for direct analysis in real time mass spectrometry.

Robert B Cody1, A John Dane1.   

Abstract

RATIONALE: Mass spectra were acquired with the Direct Analysis in Real Time (DART®) ion source for an amine-terminated polyether used as positive-ion mass reference standards and for several fluorinated materials commonly used as negative-ion reference standards for mass spectrometry.
METHODS: A commercial time-of-flight mass spectrometer equipped with a DART ion source was used for all measurements. Mass reference standards deposited onto the sealed end of a glass melting point tube were suspended in the DART gas stream for analysis.
RESULTS: A polyetheramine (Jeffamine® M-600) produced intense peaks corresponding to protonated molecules. Perfluorotributylamine (PFTBA), and perfluorotripentylamine, gave useful reference spectra for different m/z ranges. DART mass spectra of Ultramark 1621® resembled those previously reported for Fast Atom Bombardment (FAB) and Electrospray Ionization (ESI). Fomblin®Y, a fluorinated ether, was the most useful negative-ion reference standard of the materials tested. The material is commercially available, inexpensive, and provides reference peaks covering the m/z range 85 to >3000.
CONCLUSIONS: Jeffamine-M600 was found to be a convenient alternative to polyethers such as polyethylene glycol (PEG) for DART positive-ion mass calibration. Fomblin Y was suitable for use as a negative-ion reference standard.
Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Year:  2016        PMID: 28328026     DOI: 10.1002/rcm.7554

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  Elemental Composition Determinations Using the Abundant Isotope.

Authors:  Robert B Cody; Thierry Fouquet
Journal:  J Am Soc Mass Spectrom       Date:  2019-05-06       Impact factor: 3.109

2.  Ambient Profiling of Phenolic Content in Tea Infusions by Matrix-Assisted Ionization in Vacuum.

Authors:  Robert B Cody
Journal:  J Am Soc Mass Spectrom       Date:  2018-05-29       Impact factor: 3.109

3.  Resolution-Enhanced Kendrick Mass Defect Analysis of Polycyclic Aromatic Hydrocarbons and Fullerenes in the Diffusion Flame from a Butane Torch.

Authors:  Robert B Cody; Thierry Fouquet
Journal:  J Am Soc Mass Spectrom       Date:  2018-08-06       Impact factor: 3.109

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.