Literature DB >> 28326723

[Current dental implant design and its clinical importance].

Lin Ye1.   

Abstract

The development of clinical implant dentistry was intensively affected by dental implant design improvement and innovation, which brought about new concept, even milestone-like changes of clinical protocol. The current improvements of dental implant design and their clinical importance could be highlighted as followings: 1) The implant apical design influences the implant preliminary stability in immediate implant. The apical 3-5 mm design of implant makes implant stable in immediate implant, because this part would be screwed into alveolar bone through fresh socket, the other part of implant could not be tightly screwed in the socket because of smaller implant diameter. Implant apical form, screw design, self-taping of apical part would be essential for immediate implant. 2) The enough preliminary stability of implant makes immediate prosthesis possible. When osseointegration does not occur, the implant stability comes from a mechanical anchorage, which depends on implant form, screw thread and self-taping design. 3) Implant neck design may have influence for soft tissue recession in esthetic zone. The implant with large shoulder would not be selected for the esthetic area. The platform design may be more favorable in the area. 4) The connection design between implant and abutment is thought a very important structure in implant long-term stability. Moose taper and "tube in tube" were well documented structure design in 20-year clinical practice in Peking University. 5) In last 15 years, the plenty studies showed the platform design of implant had positive influence in implant marginal bone level. Whatever in single implant restoration or multi-implant prosthesis. 6) The digital technology makes clinical work more precise and high-tech. This would be a trend in implant dentistry. New generation of chair-side digital computer-aided design/computer-aided manufacturing makes immediate prosthesis without conventional impression possible. 7) New abutment design have changed clinical protocol greatly. The All-on-four concept and Weldone concept benefit both from the abutment innovation, which were large angulated abutment and special welding abutment materials.

Entities:  

Keywords:  computer-aided design; dental implant-abutment design; dental implants; immediate dental implant loading

Mesh:

Substances:

Year:  2017        PMID: 28326723      PMCID: PMC7030203          DOI: 10.7518/hxkq.2017.01.003

Source DB:  PubMed          Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi        ISSN: 1000-1182


  3 in total

Review 1.  Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review.

Authors:  Qingge Wang; Peng Zhou; Shifeng Liu; Shokouh Attarilar; Robin Lok-Wang Ma; Yinsheng Zhong; Liqiang Wang
Journal:  Nanomaterials (Basel)       Date:  2020-06-26       Impact factor: 5.076

2.  Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis.

Authors:  Yashaswini Ellendula; Anam Chandra Sekar; Sandeep Nalla; Ram B Basany; Kunchala Sailasri; Ashwini Thandu
Journal:  Cureus       Date:  2022-04-29

3.  Whole-Process Digitalization-Assisted Immediate Implant Placement and Immediate Restoration in the Aesthetic Zone: A Prospective Study.

Authors:  Xiaomei Han; Change Qi; Pengnv Guo; Shuying Zhang; Yali Xu; Guanghui Lv; Ying Li; Changyi Li
Journal:  Med Sci Monit       Date:  2021-08-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.