Literature DB >> 28321003

Midterm Outcomes With a Self-Expandable Transcatheter Heart Valve in Japanese Patients With Symptomatic Severe Aortic Stenosis.

Yoshiki Sawa1, Kei Torikai1, Junjiro Kobayashi2, Hiroshi Niinami3, Toru Kuratani1, Koichi Maeda1, Hideaki Kanzaki2, Nobuyuki Komiyama3, Yutaka Tanaka4, Angie Zhang5, Shigeru Saito4.   

Abstract

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a viable alternative to surgical aortic valve replacement in high-risk or inoperable patients with aortic stenosis (AS). Here we report the midterm outcomes of high-risk Japanese patients with severe AS who underwent TAVI with a self-expandable TAV.Methods and 
Results: The CoreValve Japan Trial was a prospective, multicenter trial of the CoreValve System. A group of 55 patients (mean age 82.5±5.5 years, 30.9% male, 100% NYHA class III/IV, STS 8.0±4.2%) were enrolled in the 26-mm/29-mm CoreValve study, and 20 patients (mean age 81.0±6.6 years, 5.0% male, 100% NYHA class III/IV, STS 7.0±3.3%) were enrolled in the 23-mm CoreValve study, which started 1 year later. For the 26-mm/29-mm cohort, the 3-year all-cause mortality rate was 32.6%; major stroke was 15.4%. Mean pressure gradient (MPG), effective orifice area (EOA), and NYHA class showed sustained improvement. Paravalvular regurgitation (PVR) at 3 years was 28.6% (none), 25.7% (trace), 40.0% (mild), 5.7% (moderate), and 0.0% (severe). For the 23-mm cohort, the 2-year all-cause mortality rate was 5.0%; major stroke was 5.0%. MPG, EOA, and NYHA class showed sustained improvement. PVR at 2 years was 16.7% (none), 33.3% (trace), 44.4% (mild), 5.6% (moderate), and 0.0% (severe).
CONCLUSIONS: TAVI with the CoreValve System was associated with sustained clinical and functional cardiac improvement in high surgical risk Japanese patients with severe AS. (Clinicaltrials.gov Identifiers: NCT01437098 and NCT01634269.).

Entities:  

Keywords:  Aortic valve stenosis; Midterm follow-up; Transcatheter aortic valve implantation

Mesh:

Year:  2017        PMID: 28321003     DOI: 10.1253/circj.CJ-17-0112

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  2 in total

1.  Hemodynamic comparison of CoreValve and SAPIEN-XT TAVI valves in Japanese patients.

Authors:  Koki Shishido; Futoshi Yamanaka; Tomoki Ochiai; Tsuyoshi Yamabe; Kenichiro Noguchi; Takashi Ota; Yasuhiro Koide; Hidemitsu Ogino; Yutaka Tanaka; Shigeru Saito
Journal:  Heart Vessels       Date:  2019-04-16       Impact factor: 2.037

2.  Two cases of lobectomy for lung cancer after transcatheter aortic valve implantation.

Authors:  Hideki Nagata; Ryu Kanzaki; Takashi Kanou; Naoko Ose; Soichiro Funaki; Yasushi Shintani; Masato Minami; Isamu Mizote; Yasushi Sakata; Koichi Maeda; Toru Kuratani; Yoshiki Sawa; Meinoshin Okumura
Journal:  Surg Case Rep       Date:  2018-12-03
  2 in total