Infections in Patients with a Total Artificial Heart Are Common but Rarely Fatal.

Luis F Hidalgo1, Keyur B Shah, Richard H Cooke, Daniel G Tang, Vigneshwar Kasirajan, Howard A Cooper, Wilbert S Aronow.   

Abstract

Patients who received a total artificial heart (TAH) at Virginia Commonwealth University (VCU) between January 1, 2010 and December 31, 2011 were identified from the VCU Mechanical Circulatory Support Clinical Database. Retrospective data extraction from the medical records was performed from the time of TAH implantation until heart transplantation or death. Infections were classified as confirmed or suspected. Twenty-seven men and five women, mean age 49.5 years (range 24-68 years) received a TAH. The mean duration of TAH support was 225 days (range 1-1,334 days). Of the 32 patients, 4 (12.5%) died and 28 (87.5 %) underwent heart transplantation. Causes of death were pneumonia (n = 1), TAH malfunction (n = 1), refractory cardiogenic shock (n = 1), and respiratory failure (n = 1). Seventy documented and 13 suspected infections developed in 25 patients (78%). The most common sources of infection were urinary tract (n = 26), respiratory tract (n = 18), and bloodstream (n = 11). There were five pump infections and two driveline infections. The number of infections per patient ranged from 0 to 10. Sixteen different pathogens were identified; the most common were: Klebsiella pneumoniae (n = 15), coagulase-negative Staphylococci (n = 10), Enterococcus species (n = 9), and Enterobacter species (n = 8). Mortality directly attributable to infection was infrequent.

Entities:  

Mesh:

Year:  2017        PMID: 28319520     DOI: 10.1097/MAT.0000000000000562

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  2 in total

1.  Comparison of SynCardia total artificial heart and HeartWare HVAD biventricular support for management of biventricular heart failure: a systematic review and meta-analysis.

Authors:  Elizabeth J Maynes; Thomas J O'Malley; Jessica G Y Luc; Matthew P Weber; Dylan P Horan; Jae Hwan Choi; Sinal Patel; Syed-Saif Abbas Rizvi; Rohinton J Morris; John W Entwistle; H Todd Massey; Vakhtang Tchantchaleishvili
Journal:  Ann Cardiothorac Surg       Date:  2020-03

Review 2.  Review and reflections about pulsatile ventricular assist devices from history to future: concerning safety and low haemolysis-still needed.

Authors:  Inge Köhne
Journal:  J Artif Organs       Date:  2020-05-04       Impact factor: 1.731

  2 in total