Literature DB >> 28318564

Comparing the selectivity and chiral separation of d- and l- fluorenylmethyloxycarbonyl chloride protected amino acids in analytical high performance liquid chromatography and supercritical fluid chromatography; evaluating throughput, economic and environmental impact.

C M Vera1, D Shock2, G R Dennis1, W Farrell3, R A Shalliker4.   

Abstract

The chiral separation of d- and l- FMOC amino acids was undertaken using the Lux Cellulose-1 polysaccharide based chiral column in HPLC (normal phase and reverse phase) and SFC conditions. This was done to compare the relative selectivity and separation between the three separation modes and to evaluate the potential benefits of SFC separations with regards to resolution, throughput, economic and environmental impact. It was established that the separation of d- and l- FMOC amino acids in SFC displayed behaviours that were similar to both normal phase and reversed phase, rather than distinctly one or the other. Additionally, although reversed phase conditions yielded significantly higher resolution values between enantiomers across the range of amino acids studied, improvements in selectivity in SFC via the introduction of higher concentrations of formic acid in the mobile phase allowed for better resolution per unit of time. Moreover since the SFC mobile phase is composed mostly of recyclable CO2, there is a reduction in organic solvent consumption, which minimises the economic and environmental costs.
Copyright © 2017. Published by Elsevier B.V.

Entities:  

Keywords:  Amino acids; Chiral chromatography; Normal phase; Reversed phase; Supercritical fluid chromatography

Mesh:

Substances:

Year:  2017        PMID: 28318564     DOI: 10.1016/j.chroma.2017.02.017

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

Review 1.  Free and Esterified Tocopherols, Tocotrienols and Other Extractable and Non-Extractable Tocochromanol-Related Molecules: Compendium of Knowledge, Future Perspectives and Recommendations for Chromatographic Techniques, Tools, and Approaches Used for Tocochromanol Determination.

Authors:  Paweł Górnaś; Georgijs Baškirovs; Aleksander Siger
Journal:  Molecules       Date:  2022-10-04       Impact factor: 4.927

2.  Chiral Discrimination of DL-Amino Acids by Trapped Ion Mobility Spectrometry after Derivatization with (+)-1-(9-Fluorenyl)ethyl Chloroformate.

Authors:  Raquel Pérez-Míguez; Ben Bruyneel; María Castro-Puyana; María Luisa Marina; Govert W Somsen; Elena Domínguez-Vega
Journal:  Anal Chem       Date:  2019-02-12       Impact factor: 6.986

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.