Literature DB >> 28316448

Chemiluminescence brings renaissance in TTI screening: Primi experientia.

Diptiranjan Rout1, Rahul Chaurasia1, Poonam Coshic1, Kabita Chatterjee1.   

Abstract

Entities:  

Year:  2017        PMID: 28316448      PMCID: PMC5345289          DOI: 10.4103/0973-6247.200777

Source DB:  PubMed          Journal:  Asian J Transfus Sci        ISSN: 0973-6247


× No keyword cloud information.
Sir, India with a population of 1.26 billion has seroprevalence rates ranging from 0.2–1%, 0.4–1.09%, and 1.8–4% for HIV, hepatitis C virus (HCV), and hepatitis B virus (HBV), respectively, in the blood donors population.[1234] Majority of the blood banks in India are using ELISA-based serologic screening for transfusion-transmissible viral infections (TTIs). The automated platform for chemiluminescence (ACLS) has been introduced in the recent past, as a newer serological screening tool that offers good precision, reliability, and high throughput.[5] Although ACLS appears to be an effective replacement for ELISA, the paucity of published research works in support of ACLS, makes this a mere assumption only. Performance evaluation and feasibility assessment of ACLS for routine TTI screening were done at our center based on its concordance with that of ELISA and nucleic acid test (NAT). Routine TTI screening of all the blood units collected from 1st to 30th September 2015, was done simultaneously by ELISA (DaVinci, Biomérieux, France) for anti-HIV (4th generation kits), anti-HCV (3rd generation kits), and hepatitis B surface antigen (HBsAg) (3rd generation kits); ACLS (Architect i1000 SR, Abbott, USA) for anti-HIV (4th generation kits), anti-HCV (3rd generation kits), and HBsAg (3rd generation kits); and NAT (Procleix Ultrio, Grifols, Hong Kong) for HIV-RNA, HCV-RNA, and HBV-DNA. All the NAT nonreactive units with discordant serology results were subjected to viral load quantification by real-time polymerase chain reaction (RT-PCR) (Cobas TaqMan, Roche, USA) for confirming the infectious status. Overall, 2.33% (75 of 3213) units were found to be TTI reactive by ≥1 method. Thirty-four (1.05%) units were found to be concordant reactive by all 3 methods, whereas 41 (1.27%) units were reported to have discordant results. Of these 41 discordant units, 29 (70.7%) units were serology only reactive (9 ELISA only, 15 ACLS only, and 5 by both) and 12 (29.3%) units were NAT-reactive irrespective of their serological results [Table 1]. Repeat serological tests for these 29 samples gave consistent results with that of earlier tests though neither NAT nor the RT-PCR could detect the infectious viral markers. However, these donors were kept under follow-up category to ascertain their infectious status as seroyields. Taking NAT as gold standard, the relative sensitivity and specificity of ELISA were 80.43% and 99.55%, respectively, and those of ACLS were 76.08% and 99.36%, respectively. The observed discrepancies among the 3 methods used, may be due to the different principles of the serological and molecular techniques or of chance occurrence due to the smaller study population. Our preliminary result with ACLS warrants a further study with a larger donor population for confirmation.
Table 1

Details of transmissible viral infection reactivity by different testing techniques

Details of transmissible viral infection reactivity by different testing techniques The shorter turn-around time and option for STAT tests give ACLS a definite edge over ELISA, especially during the preprocedural TTI screening for apheresis donors. Therefore, with comparable detection rates and faster turnaround time, ACLS appears as an acceptable alternative for ELISA when used with NAT.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  5 in total

1.  Seroprevalence and trends in transfusion transmitted infections among blood donors in a university hospital blood bank: a 5 year study.

Authors:  P Pallavi; C K Ganesh; K Jayashree; G V Manjunath
Journal:  Indian J Hematol Blood Transfus       Date:  2010-12-14       Impact factor: 0.900

2.  Individual donor nucleic acid testing for blood safety against HIV-1 and hepatitis B and C viruses in a tertiary care hospital.

Authors:  K Chatterjee; P Coshic; M Borgohain; R M Thapliyal; S Chakroborty; S Sunder
Journal:  Natl Med J India       Date:  2012 Jul-Aug       Impact factor: 0.537

3.  Prevalence of hepatitis B virus and hepatitis C virus among blood donors at a tertiary care hospital in India: a five-year study.

Authors:  Monika Meena; Tarun Jindal; Anjali Hazarika
Journal:  Transfusion       Date:  2011-01       Impact factor: 3.157

4.  Clinical performance evaluation of four automated chemiluminescence immunoassays for hepatitis C virus antibody detection.

Authors:  Sinyoung Kim; Jeong-Ho Kim; Seoyoung Yoon; Youn-Hee Park; Hyon-Suk Kim
Journal:  J Clin Microbiol       Date:  2008-10-22       Impact factor: 5.948

5.  Screening Donated Blood for Transfusion Transmitted Infections by Serology along with NAT and Response Rate to Notification of Reactive Results: An Indian Experience.

Authors:  Rahul Chaurasia; Shamsuz Zaman; Bankim Das; Kabita Chatterjee
Journal:  J Blood Transfus       Date:  2014-11-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.