Literature DB >> 28304320

Optimal radiologic position of an umbilical venous catheter tip as determined by echocardiography in very low birth weight newborns.

B C F Karber1, J C Nielsen1, D Balsam2, C Messina3, D Davidson1.   

Abstract

OBJECTIVE: To compare chest X-ray with echocardiogram (ECHO) in the localization of an umbilical venous catheter (UVC) tip in very low birth weight infants (VLBW). Secondary objectives determined the association between techniques for tip placement by the vertebral body level on X-ray, as well as the length of the thoracic inferior vena cava-right atrial (TIVC-RA) junction by ECHO. STUDY
DESIGN: Prospective, sequentially enrolled, masked, single regional perinatal center study. Shortly after birth, one or more anterior-posterior X-rays were ordered by the clinical team to verify that the UVC tip was fixed in the central right atrium (cRA) or at the TIVC-RA junction. An echocardiogram was performed as soon as possible after the last X-ray and UVC tip location was interpreted by a pediatric cardiologist. The pediatric radiologist and cardiologist were masked with regard to each other's reading.
RESULTS: The newborns (n = 51) were 27 (±3) weeks by gestational age with birth weights of 1029 (±288) grams (mean±SD). The radiologist read 50 UVC tips (98%) in the cRA or TIVC-RA junction and 1 (2%) in the LA. The cardiologist read 22 (43%) in the cRA or TIVC-RA, 21 (41%) in the LA and 8 (16%) tips could not be located in the heart. When the UVC tip was interpreted by X-ray as located in the TIVC-RA junction 8/29 (28%) were in the LA by echocardiogram. There was no agreement between vertebral level and tip position in the TIVC-RA junction, RA or LA. The TIVC-RA junction measured 6±1 mm and correlated with birth weight r = 0.54 (p < 0.001).
CONCLUSION: In VLBW newborns, placement of the UVC tip into the cRA or TIVC-RA junction by X-ray does not avoid misplacement in the left atrium as demonstrated by echocardiography. For VLBW infants, it is suggested that echocardiography may be helpful in verifying that the original placement or migration of the UVC tip into the LA has not occurred.

Entities:  

Keywords:  Umbilical venous catheter; central line; functional echocardiography; neonate; ultrasound

Mesh:

Year:  2017        PMID: 28304320     DOI: 10.3233/NPM-1642

Source DB:  PubMed          Journal:  J Neonatal Perinatal Med        ISSN: 1878-4429


  2 in total

1.  Inadvertent Migration of Umbilical Venous Catheters Often Leads to Malposition.

Authors:  Gerdina H Dubbink-Verheij; Remco Visser; Ratna N G B Tan; Arno A W Roest; Enrico Lopriore; Arjan B Te Pas
Journal:  Neonatology       Date:  2019-01-15       Impact factor: 4.035

Review 2.  Umbilical Venous Catheter Update: A Narrative Review Including Ultrasound and Training.

Authors:  Vito D'Andrea; Giorgia Prontera; Serena Antonia Rubortone; Lucilla Pezza; Giovanni Pinna; Giovanni Barone; Mauro Pittiruti; Giovanni Vento
Journal:  Front Pediatr       Date:  2022-01-31       Impact factor: 3.418

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.