Fluoroscopy time is not accurate as a surrogate for radiation exposure.

Edvard Skripochnik1, Shang A Loh1.   

Abstract

Objective The Food and Drug Administration and the Vascular Quality Initiative still utilize fluoroscopy time as a surrogate marker for procedural radiation exposure. This study demonstrates that fluoroscopy time does not accurately represent radiation exposure and that dose area product and air kerma are more appropriate measures. Methods Lower extremity endovascular interventions ( N = 145) between 2013 and 2015 performed at an academic medical center on a Siemens Artis-Zee floor mounted c-arm were identified. Data was collected from the summary sheet after every case. Scatter plots with Pearson correlation coefficients were created. A strong correlation was indicated by an r value approaching 1. Results Overall mean AK and DAP was 380.27 mGy and 4919.2 µGym2. There was a poor correlation between fluoroscopy time and total AK or DAP ( r = 0.27 and 0.32). Total DAP was strongly correlated to cine DAP and fluoroscopy DAP ( r = 0.92 vs. 0.84). The number of DSA runs and average frame rate did not affect AK or DAP levels. Mean magnification level was significantly correlated with total AK ( r = 0.53). Conclusions Fluoroscopy time shows minimal correlation with radiation delivered and therefore is a poor surrogate for radiation exposure during fluoroscopy procedures. DAP and AK are more suitable markers to accurately gauge radiation exposure.

Entities:  

Keywords:  Radiation exposure; air kerma; dose area product; endovascular intervention; fluoroscopy time

Mesh:

Year:  2017        PMID: 28304221     DOI: 10.1177/1708538117698342

Source DB:  PubMed          Journal:  Vascular        ISSN: 1708-5381            Impact factor:   1.285


  3 in total

Review 1.  [Update on radiation exposure in catheter ablation of atrial fibrillation].

Authors:  Tobias Schreiber; Nora Kähler; Verena Tscholl; Patrick Nagel; Ulf Landmesser; Martin Huemer; Philipp Attanasio
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2019-11-22

Review 2.  Radiation Protection in Interventional Radiology.

Authors:  Tushar Garg; Apurva Shrigiriwar
Journal:  Indian J Radiol Imaging       Date:  2022-01-10

Review 3.  Could radiation exposure be the Achilles' heel of distal transradial artery access?

Authors:  Anastasios Apostolos; Georgios Vasilagkos; Grigorios Tsigkas
Journal:  Indian Heart J       Date:  2022-06-15