Literature DB >> 28303611

Improving left ventricular segmentation in four-dimensional flow MRI using intramodality image registration for cardiac blood flow analysis.

Vikas Gupta1,2, Mariana Bustamante1,2, Alexandru Fredriksson1, Carl-Johan Carlhäll1,2,3, Tino Ebbers1,2.   

Abstract

PURPOSE: Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis.
METHOD: The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis.
RESULTS: High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P < 0.01). Blood flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05).
CONCLUSION: Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  4D flow MRI; MRI; blood flow analysis; cardiology; four-dimensional flow MRI; image registration

Mesh:

Year:  2017        PMID: 28303611     DOI: 10.1002/mrm.26674

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Fully automated intracardiac 4D flow MRI post-processing using deep learning for biventricular segmentation.

Authors:  Philip A Corrado; Andrew L Wentland; Jitka Starekova; Archana Dhyani; Kara N Goss; Oliver Wieben
Journal:  Eur Radiol       Date:  2022-02-17       Impact factor: 7.034

2.  Sildenafil administration improves right ventricular function on 4D flow MRI in young adults born premature.

Authors:  Philip A Corrado; Gregory P Barton; Christopher J Francois; Oliver Wieben; Kara N Goss
Journal:  Am J Physiol Heart Circ Physiol       Date:  2021-04-16       Impact factor: 5.125

3.  Exercise-induced irregular right heart flow dynamics in adolescents and young adults born preterm.

Authors:  Jacob A Macdonald; Grant S Roberts; Philip A Corrado; Arij G Beshish; Kristin Haraldsdottir; Gregory P Barton; Kara N Goss; Marlowe W Eldridge; Christopher J Francois; Oliver Wieben
Journal:  J Cardiovasc Magn Reson       Date:  2021-10-21       Impact factor: 5.364

4.  Altered Right Ventricular Filling at Four-dimensional Flow MRI in Young Adults Born Prematurely.

Authors:  Philip A Corrado; Gregory P Barton; Jacob A Macdonald; Christopher J François; Marlowe W Eldridge; Kara N Goss; Oliver Wieben
Journal:  Radiol Cardiothorac Imaging       Date:  2021-06-03

5.  Feasibility of Cardiovascular Four-dimensional Flow MRI during Exercise in Healthy Participants.

Authors:  Jacob A Macdonald; Arij G Beshish; Philip A Corrado; Gregory P Barton; Kara N Goss; Marlowe W Eldridge; Christopher J François; Oliver Wieben
Journal:  Radiol Cardiothorac Imaging       Date:  2020-06-18

6.  Reduced regional flow in the left ventricle after anterior acute myocardial infarction: a case control study using 4D flow MRI.

Authors:  Philip A Corrado; Jacob A Macdonald; Christopher J François; Niti R Aggarwal; Jonathan W Weinsaft; Oliver Wieben
Journal:  BMC Med Imaging       Date:  2019-12-30       Impact factor: 1.930

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.