The development and concurrent validity of a real-time algorithm for temporal gait analysis using inertial measurement units.

E Allseits1, J Lučarević2, R Gailey3, V Agrawal4, I Gaunaurd2, C Bennett5.   

Abstract

The use of inertial measurement units (IMUs) for gait analysis has emerged as a tool for clinical applications. Shank gyroscope signals have been utilized to identify heel-strike and toe-off, which serve as the foundation for calculating temporal parameters of gait such as single and double limb support time. Recent publications have shown that toe-off occurs later than predicted by the dual minima method (DMM), which has been adopted as an IMU-based gait event detection algorithm.In this study, a real-time algorithm, Noise-Zero Crossing (NZC), was developed to accurately compute temporal gait parameters. Our objective was to determine the concurrent validity of temporal gait parameters derived from the NZC algorithm against parameters measured by an instrumented walkway. The accuracy and precision of temporal gait parameters derived using NZC were compared to those derived using the DMM. The results from Bland-Altman Analysis showed that the NZC algorithm had excellent agreement with the instrumented walkway for identifying the temporal gait parameters of Gait Cycle Time (GCT), Single Limb Support (SLS) time, and Double Limb Support (DLS) time. By utilizing the moment of zero shank angular velocity to identify toe-off, the NZC algorithm performed better than the DMM algorithm in measuring SLS and DLS times. Utilizing the NZC algorithm's gait event detection preserves DLS time, which has significant clinical implications for pathologic gait assessment.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Gait analysis; Inertial measurement unit; Real-time; Temporal gait parameters; Toe-off identification

Mesh:

Year:  2017        PMID: 28302315     DOI: 10.1016/j.jbiomech.2017.02.016

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  9 in total

1.  A database of physical therapy exercises with variability of execution collected by wearable sensors.

Authors:  Sara García-de-Villa; Ana Jiménez-Martín; Juan Jesús García-Domínguez
Journal:  Sci Data       Date:  2022-06-03       Impact factor: 8.501

2.  Estimation of gait parameters using leg velocity for amputee population.

Authors:  Zohaib Aftab; Rizwan Shad
Journal:  PLoS One       Date:  2022-05-13       Impact factor: 3.752

3.  POST-CONCUSSIVE CHANGES IN BALANCE AND POSTURAL STABILITY MEASURED WITH CANESENSE™ AND THE BALANCE ERROR SCORING SYSTEM (BESS) IN DIVISION I COLLEGIATE FOOTBALL PLAYERS: A CASE SERIES.

Authors:  Luis A Feigenbaum; Kyoung J Kim; Ignacio A Gaunaurd; Lee D Kaplan; Vincent A Scavo; Christopher Bennett; Robert S Gailey
Journal:  Int J Sports Phys Ther       Date:  2019-04

4.  Exposure to an extreme environment comes at a sensorimotor cost.

Authors:  Kyoung Jae Kim; Yoav Gimmon; Sharmeen Sorathia; Kara H Beaton; Michael C Schubert
Journal:  NPJ Microgravity       Date:  2018-09-05       Impact factor: 4.415

5.  A Novel Method for Estimating Knee Angle Using Two Leg-Mounted Gyroscopes for Continuous Monitoring with Mobile Health Devices.

Authors:  Eric Allseits; Kyoung Jae Kim; Christopher Bennett; Robert Gailey; Ignacio Gaunaurd; Vibhor Agrawal
Journal:  Sensors (Basel)       Date:  2018-08-22       Impact factor: 3.576

6.  Gait Phase Detection Based on Muscle Deformation with Static Standing-Based Calibration.

Authors:  Tamon Miyake; Shintaro Yamamoto; Satoshi Hosono; Satoshi Funabashi; Zhengxue Cheng; Cheng Zhang; Emi Tamaki; Shigeki Sugano
Journal:  Sensors (Basel)       Date:  2021-02-04       Impact factor: 3.576

Review 7.  Wearable Sensor-Based Real-Time Gait Detection: A Systematic Review.

Authors:  Hari Prasanth; Miroslav Caban; Urs Keller; Grégoire Courtine; Auke Ijspeert; Heike Vallery; Joachim von Zitzewitz
Journal:  Sensors (Basel)       Date:  2021-04-13       Impact factor: 3.576

8.  Effect of Torso Kinematics on Gait Phase Estimation at Different Walking Speeds.

Authors:  Woolim Hong; Jinwon Lee; Pilwon Hur
Journal:  Front Neurorobot       Date:  2022-03-30       Impact factor: 2.650

Review 9.  Validity and reliability of wearable inertial sensors in healthy adult walking: a systematic review and meta-analysis.

Authors:  Dylan Kobsar; Jesse M Charlton; Calvin T F Tse; Jean-Francois Esculier; Angelo Graffos; Natasha M Krowchuk; Daniel Thatcher; Michael A Hunt
Journal:  J Neuroeng Rehabil       Date:  2020-05-11       Impact factor: 4.262

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.