INTRODUCTION: The aim of the present study was to compare the shaping ability of Reciproc (RPC; VDW, Munich, Germany), HyFlex EDM (HEDM; Coltene/Whaledent AG, Altstätten, Switzerland), and WaveOne GOLD (WOG; Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium (NiTi) files made of different NiTi alloys in S-shaped simulated canals.
METHODS: Sixty S-shaped canals in resin blocks were prepared to an apical size of 0.25 mm using RPC R25, WOG Primary, and HEDM OneFile (n = 20 canal/per group) systems. Composite images were made from the superimposition of pre- and postinstrumentation images. The amount of resin removed by each system was measured using a digital template and image analysis software in 22 different points. Canal aberrations were also recorded. Data were statistically analyzed using the Kruskal-Wallis and post hoc Dunn tests at the 5% level.
RESULTS: NiTi file fracture was not observed during shaping of the simulated canals although a danger zone formation in 1 sample and a ledge in 1 sample were observed in the RPC group. There was no statistically significant difference between the WOG and HEDM groups' apical, medial, and coronal regions (P > .05). However, it was determined that the RPC group removed a statistically significantly higher amount of resin from all the canal regions when compared with the WOG and HEDM groups (P < .05).
CONCLUSIONS: Within the limitation of the present study, it was determined that all of the tested NiTi files caused various levels of resin removal. However, WOG and HEDM NiTi files were found to cause a lower level of resin removal than RPC NiTi files.
Copyright © 2017 American Association of Endodontists. All rights reserved.

Entities:  

Keywords:  Canal irregularity; GOLD wire; controlled memory; endodontics; nickel-titanium; shaping ability

Mesh:

Substances:

Year:  2017        PMID: 28292599     DOI: 10.1016/j.joen.2016.12.010

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  11 in total

1.  Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments.

Authors:  Emmanuel João Nogueira Leal Silva; Victor Talarico Leal Vieira; Fernanda Hecksher; Marja Ribeiro Silva Dos Santos Oliveira; Henrique Dos Santos Antunes; Edson Jorge Lima Moreira
Journal:  Clin Oral Investig       Date:  2018-02-01       Impact factor: 3.573

2.  Cone-beam computed tomography assessment of root canal transportation using WaveOne Gold and Neoniti single-file systems.

Authors:  Saritha Vallabhaneni; Kainath Fatima; Twino H Kumar
Journal:  J Conserv Dent       Date:  2017 Nov-Dec

3.  Shaping Ability of 2Shape and WaveOne Gold Files Using Cone-Beam Computed Tomography.

Authors:  Shalini Singh; Nitin Mirdha; P H Shilpa; Rahul V C Tiwari; Muqthadir Siddiqui Mohammad Abdul; Shan Sainudeen
Journal:  J Int Soc Prev Community Dent       Date:  2019-06-07

Review 4.  Nickel-Titanium Rotary File Systems: What's New?

Authors:  Sadia Tabassum; Kamil Zafar; Fahad Umer
Journal:  Eur Endod J       Date:  2019-10-18

5.  Comparison of Shaping Ability of Different Single-File Systems Using Microcomputed Tomography.

Authors:  Mohamed Mohamed Elashiry; Shehab Eldin Saber; Salma Hasan Elashry
Journal:  Eur J Dent       Date:  2020-01-31

6.  Three-dimensional analysis of the root canal preparation with Reciproc Blue®, WaveOne Gold® and XP EndoShaper®: a new method in vivo.

Authors:  Javier Caviedes-Bucheli; Nestor Rios-Osorio; Diana Usme; Cristian Jimenez; Adriana Pinzon; Jorge Rincón; María M Azuero-Holguin; Alvaro Zubizarreta-Macho; Jose F Gomez-Sosa; Hugo R Munoz
Journal:  BMC Oral Health       Date:  2021-02-25       Impact factor: 2.757

7.  Shaping ability of ProTaper Gold and WaveOne Gold nickel-titanium rotary instruments in simulated S-shaped root canals.

Authors:  Lu Shi; Junling Zhou; Jie Wan; Yunfei Yang
Journal:  J Dent Sci       Date:  2021-08-30       Impact factor: 2.080

8.  An in vitro Comparative Evaluation of Volume of Removed Dentin, Canal Transportation, and Centering Ratio of 2Shape, WaveOne Gold, and ProTaper Gold Files Using Cone-Beam Computed Tomography.

Authors:  Shalini Singh; Muqthadir Siddiqui Mohammed Abdul; Utsav Sharma; Shan Sainudeen; Chayan Jain; Jacob Tony Kalliath
Journal:  J Int Soc Prev Community Dent       Date:  2019-09-30

9.  Shaping Ability of XP Endo Shaper File in Curved Root Canal Models.

Authors:  Abdulmohsen Alfadley; Abdalrhman Alrajhi; Hamad Alissa; Faisal Alzeghaibi; Lubna Hamadah; Khalid Alfouzan; Ahmed Jamleh
Journal:  Int J Dent       Date:  2020-02-17

10.  Micro-CT evaluation of rotary and reciprocating glide path and shaping systems outcomes in maxillary molar curved canals.

Authors:  Mario Alovisi; Damiano Pasqualini; Nicola Scotti; Giorgia Carpegna; Allegra Comba; Mattia Bernardi; Fabio Tutino; Mario Dioguardi; Elio Berutti
Journal:  Odontology       Date:  2021-06-25       Impact factor: 2.634