Literature DB >> 28291530

After the Recall: Reexamining Multiple Magnet Ingestion at a Large Pediatric Hospital.

Daniel Rosenfield1, Matt Strickland2, Charlotte Moore Hepburn3.   

Abstract

OBJECTIVES: To evaluate the effectiveness of a mandatory product recall on the frequency of multiple mini-magnet ingestion at a large tertiary pediatric hospital, and to examine the morbidity and mortality associated with these ingestions. STUDY
DESIGN: In this retrospective chart review, we searched our institution's electronic patient record for patients aged <18 years who had been diagnosed with ingested magnetic foreign bodies between 2002 and 2015, a period that included the mandatory product recall. We compared the frequency and character of ingestions before and after the recall.
RESULTS: Comparing the postrecall years (January 1, 2014, to December 31, 2015) with the 2 years immediately preceding the recall year (January 1, 2011, to December 31, 2012) yields an incidence rate ratio of 0.34 (95% CI, 0.18-0.64) for all magnet ingestions and 0.20 (95% CI, 0.08-0.53) for ingestion of multiple magnets. Based on the Fisher exact test, the incidence of both magnet ingestion (P < .001) and multiple magnet ingestion (P < .001) decreased, and the morbidity associated with magnet ingestion decreased. There were no deaths in either study period.
CONCLUSION: There was a significant decrease in multiple mini-magnet ingestion following a mandatory product recall. This study supports the effectiveness of the recall, which should bolster efforts to keep it in place in jurisdictions where it is being appealed. More broadly, the result provides general evidence of a recall helping decrease further harm from a product that carries a potential hazard.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  foreign bodies; injury; magnets; pediatrics; perforation

Mesh:

Year:  2017        PMID: 28291530     DOI: 10.1016/j.jpeds.2017.02.002

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  2 in total

1.  Retrospective analysis of pediatric patients with multiple rare-earth magnets ingestion: a single-center experience from China.

Authors:  Min Lian; Zhifeng Liu; Yucan Zheng; Zhihua Zhang; Kunlong Yan; Hongmei Guo; Mei Li
Journal:  BMC Pediatr       Date:  2021-04-17       Impact factor: 2.125

2.  Multicenter investigation of pediatric gastrointestinal tract magnets ingestion in China.

Authors:  Kai Wang; Dan Zhang; Xianling Li; Zengmeng Wang; Guangjun Hou; Xinjian Jia; Huizhong Niu; Shiqin Qi; Qingqiang Deng; Bin Jiang; Hongqiang Bian; Heying Yang; Yajun Chen
Journal:  BMC Pediatr       Date:  2020-02-28       Impact factor: 2.125

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.