Literature DB >> 28290370

Calibration strategies for the direct determination of Ca, K, and Mg in commercial samples of powdered milk and solid dietary supplements using laser-induced breakdown spectroscopy (LIBS).

Amanda Dos Santos Augusto1, Paulo Lopes Barsanelli2, Fabiola Manhas Verbi Pereira2, Edenir Rodrigues Pereira-Filho3.   

Abstract

This study describes the application of laser-induced breakdown spectroscopy (LIBS) for the direct determination of Ca, K and Mg in powdered milk and solid dietary supplements. The following two calibration strategies were applied: (i) use of the samples to calculate calibration models (milk) and (ii) use of sample mixtures (supplements) to obtain a calibration curve. In both cases, reference values obtained from inductively coupled plasma optical emission spectroscopy (ICP OES) after acid digestion were used. The emission line selection from LIBS spectra was accomplished by analysing the regression coefficients of partial least squares (PLS) regression models, and wavelengths of 534.947, 766.490 and 285.213nm were chosen for Ca, K and Mg, respectively. In the case of the determination of Ca in supplements, it was necessary to perform a dilution (10-fold) of the standards and samples to minimize matrix interference. The average accuracy for powdered milk ranged from 60% to 168% for Ca, 77% to 152% for K and 76% to 131% for Mg. In the case of dietary supplements, standard error of prediction (SEP) varied from 295 (Mg) to 3782mgkg-1 (Ca). The proposed method presented an analytical frequency of around 60 samples per hour and the step of sample manipulation was drastically reduced, with no generation of toxic chemical residues.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Calibration; Chemometrics; Dietary supplements; Direct solid analysis; Laser-induced breakdown spectroscopy; Powdered milk

Mesh:

Substances:

Year:  2017        PMID: 28290370     DOI: 10.1016/j.foodres.2017.01.027

Source DB:  PubMed          Journal:  Food Res Int        ISSN: 0963-9969            Impact factor:   6.475


  2 in total

1.  Determination of toxic metals in leather by wavelength dispersive X-ray fluorescence (WDXRF) and inductively coupled plasma optical emission spectrometry (ICP OES) with emphasis on chromium.

Authors:  Ariane Maciel Neiva; Marco Aurelio Sperança; Vinicius Câmara Costa; Manuel Antonio Chagas Jacinto; Edenir Rodrigues Pereira-Filho
Journal:  Environ Monit Assess       Date:  2018-09-28       Impact factor: 2.513

2.  Real-Time Analysis of Potassium in Infant Formula Powder by Data-Driven Laser-Induced Breakdown Spectroscopy.

Authors:  Da Chen; Jing Zong; Zhixuan Huang; Junxin Liu; Qifeng Li
Journal:  Front Chem       Date:  2018-07-31       Impact factor: 5.221

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.