Literature DB >> 28290164

Risk Factors for Permanent Pacemaker after Implantation of Surgical or Percutaneous Self-Expanding Aortic Prostheses.

Emmanuel Villa1, Alberto Clerici2, Antonio Messina3, Luca Testa2, Francesco Bedogni2, Andrea Moneta2, Francesco Donatelli2, Giovanni Troise3.   

Abstract

BACKGROUND: The use of transcatheter aortic valve implantation (TAVI) following the introduction of Nitinol autoexpandable devices has spread rapidly during recent years. In addition, cardiac surgery has been revolutionized due to the use of Nitinol-based sutureless prostheses for aortic valve replacement (AVR). During the same period, however, permanent pacemaker (PPM) implantation has emerged as a frequent complication. The study aim was to identify the risk factors of PPM following the implantation of a Nitinol self-expanding prosthesis (for AVR or TAVI).
METHODS: A study group was created between two institutions experienced in the use of nitinol devices, and a pool of 336 patients (56.6% CoreValve - Medtronic; 43.4% Perceval - Sorin) was available for a retrospective analysis. Pre-procedural clinical and electrocardiography (ECG) variables and postprocedural ECG variables were compared between the PPM group and control patients who had not received a PPM during their index hospitalization.
RESULTS: A PPM was required in 12.8% of patients (TAVI 17.5% versus AVR 6.8%, p = 0.007). PPM patients had a higher logistical EuroSCORE (median 20.77% versus 15.59%, p = 0.015), a lower use of statins (18.6% versus 34.2%, p = 0.04), a pre-procedural longer QRS interval (median 117 ms versus 98 ms, p = 0.002), and a higher incidence of conduction disturbances (29.3% versus 16.8%, p = 0.034), with a prevalence of right bundle branch block. At the first postprocedural ECG, non-stimulated PPM patients had a longer QRS interval (median 150 ms versus 113 ms, p<0.001) and a longer QTc interval (487.3 ± 46 ms versus 510.8 ± 53.8 ms, p = 0.005). Prevalent intra-ventricular conduction disorders in both groups included left bundle branch block. AVR patients received a PPM later than the TAVI group (median 6 days versus 3 days, p = 0.01). TAVI was an independent predictor of PPM at logistic regression analysis (OR 3.18; 95% CI 1.19-8.48, p = 0.021), but the significance disappeared after incorporating post-procedural ECG variables.
CONCLUSIONS: Nitinol technology is a ground-breaking option for aortic valve procedures. However, the radial forces of the self-expandable mechanism may be implicated in the increased need for PPM, mostly in cases of TAVI compared to AVR, that most likely are due to displacement of the stent provoked by in situ calcium clusters. Given the clinical and economic impact of PPM, new parameters are required to understand the stent/tissue interaction and to help with device selection.

Entities:  

Mesh:

Year:  2016        PMID: 28290164

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  4 in total

1.  Analysis of postoperative complications and risk factors in patients with permanent pacemaker implantation.

Authors:  Songbo Jing; Shan Hu; Shuai Ma
Journal:  J Thorac Dis       Date:  2020-10       Impact factor: 2.895

2.  A running suture line for aortic valve replacement does not increase the rate of postoperative complete heart block.

Authors:  Ibrahim Sultan; Keith A Dufendach; Arman Kilic; Valentino Bianco; Forozan Navid; Thomas G Gleason
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-09-12

3.  Direct comparison of rapid deployment versus sutureless aortic valve replacement: a meta-analysis.

Authors:  Suk Ho Sohn; Yoonjin Kang; Ji Seong Kim; Jae Woong Choi; Myoung-Jin Jang; Ho Young Hwang
Journal:  J Thorac Dis       Date:  2021-04       Impact factor: 2.895

4.  Outcome of transcatheter aortic valve replacement in patients over 85 years of age versus patients aged 85 and younger.

Authors:  F S van den Brink; I Wijtsma; H Amrane; T N E Vossenberg; J Haenen; F Porta; A J Van Boven; S H Hofma
Journal:  Neth Heart J       Date:  2022-05-24       Impact factor: 2.854

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.