Literature DB >> 28290037

Wet granulation in rotary processor and fluid bed: Comparison of granule and tablet properties.

Jakob Kristensen1, Vibeke Wallaert Hansen2.   

Abstract

The aim of the present study was to investigate and compare granule and tablet properties of granules prepared by wet granulation in a rotary processor or a conventional fluid bed. For this purpose the working range of selected process variables was determined and a factorial study with 3 factors (equipment type, filler type, and liquid addition rate) and 1 covariate (fluidizing air flow rate) was performed. Two grades of calcium carbonate with different size and shape characteristics were applied, and the liquid addition and fluidizing air flow rates were investigated in the widest possible range. Dry mixtures of microcrystalline cellulose, polyvinyl povidone, calcium carbonate, and riboflavin, in a 10∶5∶84∶1 ratio, were granulated in both types of equipment. The granulation end point was determined manually in the fluid bed and by torque measurements in the rotary processor. The filler type had a more pronounced effect on granular properties in the fluid bed, but the rotary processor showed a higher dependency on the investigated process variables. The rotary processor gave rise to more dense granules with better flow properties, but the fluid bed granules had slightly better compressional properties. Furthermore, the distribution of a low-dose drug was found to be more homogeneous in the rotary processor granules and tablets. Generally, wet granulation in a rotary processor was found to be a good alternative to conventional fluid bed granulation, especially when cohesive powders with poor flow properties or formulations with low drug content are to be granulated by a fluidizing air technique.

Entities:  

Keywords:  Wet granulation; fluid bed; rotary processor

Year:  2017        PMID: 28290037      PMCID: PMC2750729          DOI: 10.1208/pt070122

Source DB:  PubMed          Journal:  AAPS PharmSciTech        ISSN: 1530-9932            Impact factor:   3.246


  5 in total

1.  Direct pelletization in a rotary processor controlled by torque measurements. I. Influence of process variables.

Authors:  J Kristensen; T Schaefer; P Kleinebudde
Journal:  Pharm Dev Technol       Date:  2000       Impact factor: 3.133

2.  Effervescent atomization of aqueous polymer solutions and dispersions.

Authors:  F J Petersen; O Wørts; T Schaefer; P E Sojka
Journal:  Pharm Dev Technol       Date:  2001       Impact factor: 3.133

3.  Wet spheronization by rotary processing--a multistage single-pot process for producing spheroids.

Authors:  L Gu; C V Liew; P W S Heng
Journal:  Drug Dev Ind Pharm       Date:  2004-02       Impact factor: 3.225

4.  Direct pelletization in a rotary processor controlled by torque measurements. II: effects of changes in the content of microcrystalline cellulose.

Authors:  J Kristensen; T Schaefer; P Kleinebudde
Journal:  AAPS PharmSci       Date:  2000

5.  Direct pelletization in a rotary processor controlled by torque measurements. III. Investigation of microcrystalline cellulose and lactose grade.

Authors:  Jakob Kristensen
Journal:  AAPS PharmSciTech       Date:  2005-10-24       Impact factor: 3.246

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.