Preparation of MS2-based nanoparticles as control and standard materials for the molecular detection of dengue virus serotypes.

Yu Fu1, Guojing Wang2, Qisheng Wu3, Xin Yang3, Rui Zhang4, Kuo Zhang4, Guigao Lin4, Yanxi Han4, Lihua Bao5, Ziyang Li3, Jinming Li6.   

Abstract

To quantify dengue virus (DENV) and evaluate the performance of clinical laboratories using quantitative real-time polymerase chain reaction (qRT-PCR) assays, we constructed high-efficiency expression systems to produce DENV-1 to 4 nanoparticles and assessed their suitability as standard and control materials in 20 laboratories across China. Targeted gene sequences of DENV-1 to 4 were synthesized and inserted into pACYC-Duet 1-MS2 recombinant plasmids to generate corresponding nanoparticle expression systems. After collection, verification, and quantification by digital PCR (dPCR), DENV-1 to 4 nanoparticles were prepared as control and standard materials. Five positive and three negative samples of each DENV serotype in every panel were used for assessing the performance of the participating laboratories across China, as well as standard materials for the quantitative detection of DENV using qRT-PCR assays. The accuracy, sensitivity, and specificity of qRT-PCR used by the 20 evaluated laboratories were 89.6 (569/635), 85.1 (336/395), and 97.1% (233/240), respectively. Overall, sixteen (80.0%) laboratories were qualified in detecting DENV, among which five (25.0%) were designated as "competent", eleven (55.0%) were defined as "acceptable", and four (20%) were considered to be "improvable". The results generated from the DENV standard samples were significantly positively correlated with those generated by dPCR (r2=0.8698, P<0.001). In summary, DENV nanoparticles could potentially be used as controls for improving the performance of laboratories and as standards for the quantitative detection of DENV.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Control; Dengue fever; Digital polymerase chain reaction; Nanoparticle; Quantitative real-time polymerase chain reaction; Standard

Mesh:

Substances:

Year:  2017        PMID: 28288812     DOI: 10.1016/j.virusres.2017.02.011

Source DB:  PubMed          Journal:  Virus Res        ISSN: 0168-1702            Impact factor:   3.303


  1 in total

1.  Comparison of seven commercial SARS-CoV-2 nucleic acid detection reagents with pseudovirus as quality control material.

Authors:  Ying Yan; Le Chang; Wenxin Luo; Junyi Liu; Fei Guo; Lunan Wang
Journal:  J Mol Diagn       Date:  2020-12-28       Impact factor: 5.568

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.