Clinical assessment of coiled fiducial markers as internal surrogates for hepatocellular carcinomas during gated stereotactic body radiotherapy with a real-time tumor-tracking system.

Hideki Hanazawa1, Shotaro Takahashi2, Takehiro Shiinoki2, Sung Chul Park2, Yuki Yuasa2, Masahiro Koike3, Shinji Kawamura3, Keiko Shibuya2.   

Abstract

BACKGROUND AND
PURPOSE: To report the clinical usefulness of coiled fiducial markers as an internal surrogate in gated stereotactic body radiotherapy (SBRT) for hepatocellular carcinoma (HCC) using a real-time tumor-tracking radiotherapy (RTRT) system.
MATERIALS AND METHODS: Seventeen HCC patients with Child-Pugh (CP) scores of A or B received gated SBRT (45-50Gy in 5-10 fractions) using an RTRT system and Visicoil markers. Local control (LC), progression-free (PFS), and overall survival (OS) rates were assessed using the Kaplan-Meier method. Toxicities were assessed using the Common Terminology Criteria for Adverse Events, Version 4.0.
RESULTS: Of the 17 patients, 14 had a CP score A. The mean planning target volume was 54.6cc. Only 1 patient developed pneumothorax after marker implantation. Visicoil tracking during SBRT was possible in all cases. With a median follow-up of 16months, 1-year LC, PFS, and OS rates were 100%, 53%, and 82%, respectively. Grade≥2 late toxicity was observed in 2 patients (grade 2 duodenal ulcer and grade 3 temporary transaminase elevation).
CONCLUSIONS: Using an RTRT system and Visicoil markers, gated SBRT was well tolerated in patients with HCC. This can be considered a safe treatment strategy with potential for delivering favorable outcomes.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Hepatocellular carcinomas; Radiotherapy; Real-time tumor-tracking radiotherapy system; Visicoil markers

Mesh:

Year:  2017        PMID: 28285839     DOI: 10.1016/j.radonc.2017.02.010

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  4 in total

1.  Investigation of fiducial marker recognition possibility by water equivalent length in real-time tracking radiotherapy.

Authors:  Kenji Yasue; Hiraku Fuse; Yuto Asano; Miho Kato; Kazuya Shinoda; Hideaki Ikoma; Tatsuya Fujisaki; Yoshio Tamaki
Journal:  Jpn J Radiol       Date:  2021-10-16       Impact factor: 2.374

2.  Anemia is a Prognostic Factor for Overall Survival Rate in Patients with Non-Small Cell Lung Cancer Treated with Stereotactic Body Radiation Therapy.

Authors:  Hidekazu Tanaka; Taiki Ono; Yuki Manabe; Miki Kajima; Koya Fujimoto; Yuki Yuasa; Takehiro Shiinoki; Yoshikazu Yamaji; Kazuto Matsunaga
Journal:  Cancer Manag Res       Date:  2021-09-27       Impact factor: 3.989

3.  A novel dynamic robotic moving phantom system for patient-specific quality assurance in real-time tumor-tracking radiotherapy.

Authors:  Takehiro Shiinoki; Fumitake Fujii; Koya Fujimoto; Yuki Yuasa; Tatsuhiro Sera
Journal:  J Appl Clin Med Phys       Date:  2020-04-13       Impact factor: 2.102

4.  Evaluation of the effects of motion mitigation strategies on respiration-induced motion in each pancreatic region using cine-magnetic resonance imaging.

Authors:  Koya Fujimoto; Takehiro Shiinoki; Yuki Yuasa; Ryota Onizuka; Masatoshi Yamane
Journal:  J Appl Clin Med Phys       Date:  2019-08-05       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.