Literature DB >> 28279857

Performance of two blood culture systems to detect anaerobic bacteria. Is there any difference?

Manica Mueller-Premru1, Samo Jeverica2, Lea Papst3, Elisabeth Nagy4.   

Abstract

We studied the performance characteristics of two blood culture (BC) bottles/systems, (i) BacT/ALERT-FN Plus/3D (bioMérieux, Marcy l'Étoile, France) and (ii) BACTEC-Lytic/9000 (Becton Dickinson, Sparks, USA) for detection of growth and time-to-positivity (TTP) against a balanced and diverse collection of anaerobic bacterial strains (n = 48) that included reference strains (n = 19) and clinical isolates (n = 29) of 32 species (15 Gram-negative and 17 Gram-positive). Standard suspension of bacteria was inoculated to each bottle in duplicates and incubated in the corresponding system. Overall, 62.5% (n = 30) of strains were detected by both BC bottle types. Comparing the two, 70.8% (n = 34) and 79.2% (n = 38) of strains were detected by BacT/ALERT-FN Plus and BACTEC-Lytic bottles, respectively (p = 0.38). Among Gram-negative anaerobes (n = 25) the detection rate was 76.0% (n = 19) vs. 92.0% (n = 23) (p = 0.22), respectively. Among Gram-positive anaerobes (n = 23) the detection rate was 65.2% (n = 15) in both bottles (p = 1). The average TTP per bottle was calculated only for the strains detected by both systems (n = 30) and was 40.85 h and 28.08 h for BacT/ALERT-FN Plus and BACTEC-Lytic, respectively (p < 0.001). The mean difference was 12.76 h (95% CI: 6.21-19-31 h). Six anaerobic strains were not detected by any system, including Gram-negative Porphyromonas gingivalis, and five Gram-positive strains: Finegoldia magna, Peptostreptococcus anaerobius, Propionibacterium acnes, Clostridium novyi and Clostridium clostridioforme. Furthermore, Eggerthella lenta and Prevotella bivia were detected only by BacT/ALERT-FN Plus, while Prevotella disiens and Prevotella intermedia were detected only by BACTEC-Lytic bottles. There were no major differences in detection rate among clinical and reference strains. Anaerobic bacteria represent a minority of BC isolates, however, far from ideal detection rate was observed in this study for both tested bottle/system combinations. Nevertheless, in those cases where both gave positive signal, BACTEC-Lytic was superior to BacT/ALERT FN Plus with 12.76 h shorter mean TTP. Improvements of media in blood culture bottles available for detection of anaerobes are warranted.
Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  Anaerobe; Blood culture system; Detection rate; Time-to-positivity

Mesh:

Year:  2017        PMID: 28279857     DOI: 10.1016/j.anaerobe.2017.03.006

Source DB:  PubMed          Journal:  Anaerobe        ISSN: 1075-9964            Impact factor:   3.331


  3 in total

1.  Direct Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Testing from Positive Blood Cultures for Rapid Identification of Bloodstream Infection-Causing Anaerobic Bacteria.

Authors:  Tiziana D'Inzeo; Barbara Fiori; Brunella Posteraro; Teresa Spanu; Flora Marzia Liotti; Venere Cortazzo; Debora Talamonti; Federica Ventriglia; Flavio De Maio; Elena De Carolis; Maurizio Sanguinetti
Journal:  J Clin Microbiol       Date:  2021-06-18       Impact factor: 5.948

2.  Comparison of the Performance of Three Blood Culture Systems in a Chinese Tertiary-Care Hospital.

Authors:  Guanlin Li; Jingjing Sun; Shoucheng Pan; Wenti Li; Shijie Zhang; Yongfeng Wang; Xiaoxu Sun; Hui Xu; Liang Ming
Journal:  Front Cell Infect Microbiol       Date:  2019-08-07       Impact factor: 5.293

3.  Renal and perinephric abscesses involving Lactobacillus jensenii and Prevotella bivia in a young woman following ureteral stent procedure.

Authors:  Abhinav Mohan; Jacob Rubin; Priyank Chauhan; Juan Lemos Ramirez; German Giese
Journal:  J Community Hosp Intern Med Perspect       Date:  2020-03-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.