Intracranial Pressure Values Are Highly Variable After Cerebral Spinal Fluid Drainage.

Michael Rogers1, Sonja E Stutzman, Folefac D Atem, Samarpita Sengupta, Babu Welch, DaiWai M Olson.   

Abstract

Intracranial pressure (ICP) is often obtained via external ventricular drain (EVD) placement and is discussed as a key vital sign in neuroscience. Nurses are most often delegated the task of observing, adjudicating, and documenting ICP. Cerebrospinal fluid drainage requires that the transducer connected to the EVD is open to drain, prohibiting ICP monitoring. There are no recent data to support an evidence-based standard for the period an ICP waveform should be observed, after the EVD is clamped, to be able to adjudicate a value that represents the patient's status. Therefore, the purpose of this study is to determine the optimal period for which an EVD should be closed to obtain an accurate ICP value. In a sample of 30 subjects who received continuous ICP monitoring for 15 minutes, there was no universal pattern to ICP after clamping an EVD. The conditional probability of observing a patient's highest ICP, if ICP is observed for 5 minutes, is 0.0181. The conditional probability increased to 0.0402 if ICP is observed for 10 minutes. There were no instances of ICP elevation requiring intervention. The results suggest that at least 5 minutes of ICP monitoring is safe and is required to provide an ICP value that reflects true ICP.

Entities:  

Mesh:

Year:  2017        PMID: 28277450     DOI: 10.1097/JNN.0000000000000257

Source DB:  PubMed          Journal:  J Neurosci Nurs        ISSN: 0888-0395            Impact factor:   1.230


  3 in total

1.  Differentiate the Source and Site of Intracranial Pressure Measurements Using More Precise Nomenclature.

Authors:  DaiWai M Olson; Stefany Ortega Peréz; Jonathan Ramsay; Chethan P Venkatasubba Rao; Jose I Suarez; Molly McNett; Venkatesh Aiyagari
Journal:  Neurocrit Care       Date:  2019-04       Impact factor: 3.210

Review 2.  Evidence-Based Management of External Ventricular Drains.

Authors:  David Y Chung; DaiWai M Olson; Sayona John; Wazim Mohamed; Monisha A Kumar; Bradford B Thompson; Guy A Rordorf
Journal:  Curr Neurol Neurosci Rep       Date:  2019-11-26       Impact factor: 5.081

3.  Intracranial Pressure Monitoring via External Ventricular Drain: Are We Waiting Long Enough Before Recording the Real Value?

Authors:  Xiuyun Liu; Margaret Griffith; Hannah J Jang; Nerissa Ko; Michele M Pelter; Jacob Abba; Maximilian Vuong; Nate Tran; Kelly Bushman; Xiao Hu
Journal:  J Neurosci Nurs       Date:  2020-02       Impact factor: 1.230

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.