Literature DB >> 28269536

Nonlinear 3-D simulation of high-intensity focused ultrasound therapy in the Kidney.

Visa Suomi, Jiri Jaros, Bradley Treeby, Robin Cleveland.   

Abstract

Kidney cancer is a severe disease which can be treated non-invasively using high-intensity focused ultrasound (HIFU) therapy. However, tissue in front of the transducer and the deep location of kidney can cause significant losses to the efficiency of the treatment. The effect of attenuation, refraction and reflection due to different tissue types on HIFU therapy of the kidney was studied using a nonlinear ultrasound simulation model. The geometry of the tissue was derived from a computed tomography (CT) dataset of a patient which had been segmented for water, bone, soft tissue, fat and kidney. The combined effect of inhomogeneous attenuation and soundspeed was found to result in an 11.0 dB drop in spatial peak-temporal average (SPTA) intensity in the kidney compared to pure water. The simulation without refraction effects showed a 6.3 dB decrease indicating that both attenuation and refraction contribute to the loss in focal intensity. The losses due to reflections at soft tissue interfaces were less than 0.1 dB. Focal point shifting due to refraction effects resulted in -1.3, 2.6 and 1.3 mm displacements in x-, y- and z-directions respectively. Furthermore, focal point splitting into several smaller subvolumes was observed. The total volume of the secondary focal points was approximately 46% of the largest primary focal point. This could potentially lead to undesired heating outside the target location and longer therapy times.

Entities:  

Mesh:

Year:  2016        PMID: 28269536      PMCID: PMC5525134          DOI: 10.1109/EMBC.2016.7592008

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  11 in total

1.  A prospective, randomised EORTC intergroup phase 3 study comparing the oncologic outcome of elective nephron-sparing surgery and radical nephrectomy for low-stage renal cell carcinoma.

Authors:  Hendrik Van Poppel; Luigi Da Pozzo; Walter Albrecht; Vsevolod Matveev; Aldo Bono; Andrzej Borkowski; Marc Colombel; Laurence Klotz; Eila Skinner; Thomas Keane; Sandrine Marreaud; Sandra Collette; Richard Sylvester
Journal:  Eur Urol       Date:  2010-12-22       Impact factor: 20.096

Review 2.  Extracorporeal ablation of renal tumours with high-intensity focused ultrasound.

Authors:  Michael Marberger; G Schatzl; David Cranston; J E Kennedy
Journal:  BJU Int       Date:  2005-03       Impact factor: 5.588

3.  MRI monitoring of the effect of tissue interfaces in the penetration of high intensity focused ultrasound in kidney in vivo.

Authors:  Christakis Damianou
Journal:  Ultrasound Med Biol       Date:  2004-09       Impact factor: 2.998

4.  Extracorporeal high intensity focused ultrasound for renal tumours: a 3-year follow-up.

Authors:  Robert W Ritchie; Tom Leslie; Rachel Phillips; Feng Wu; Rowland Illing; Gail ter Haar; Andrew Protheroe; David Cranston
Journal:  BJU Int       Date:  2010-03-04       Impact factor: 5.588

5.  Radiofrequency ablation of renal cell carcinoma: part 1, Indications, results, and role in patient management over a 6-year period and ablation of 100 tumors.

Authors:  Debra A Gervais; Francis J McGovern; Ronald S Arellano; W Scott McDougal; Peter R Mueller
Journal:  AJR Am J Roentgenol       Date:  2005-07       Impact factor: 3.959

6.  Renal tumour size measured radiologically before surgery is an unreliable variable for predicting histopathological features: benign tumours are not necessarily small.

Authors:  Mesut Remzi; Daniela Katzenbeisser; Matthias Waldert; Hans-Christoph Klingler; Martin Susani; Mazda Memarsadeghi; Gertraud Heinz-Peer; Andrea Haitel; Ralf Herwig; Michael Marberger
Journal:  BJU Int       Date:  2007-05       Impact factor: 5.588

7.  Renal cryoablation: outcome at 3 years.

Authors:  Inderbir S Gill; Erick M Remer; Waleed A Hasan; Brenda Strzempkowski; Massimiliano Spaliviero; Andrew P Steinberg; Jihad H Kaouk; Mihir M Desai; Andrew C Novick
Journal:  J Urol       Date:  2005-06       Impact factor: 7.450

8.  Attenuation and de-focusing during high-intensity focused ultrasound therapy through peri-nephric fat.

Authors:  Robert Ritchie; Jamie Collin; Constantin Coussios; Tom Leslie
Journal:  Ultrasound Med Biol       Date:  2013-08-09       Impact factor: 2.998

9.  Comparative analysis of laparoscopic versus open partial nephrectomy for renal tumors in 200 patients.

Authors:  Inderbir S Gill; Surena F Matin; Mihir M Desai; Jihad H Kaouk; Andrew Steinberg; Ed Mascha; Julie Thornton; Mahmoud H Sherief; Brenda Strzempkowski; Andrew C Novick
Journal:  J Urol       Date:  2003-07       Impact factor: 7.450

10.  The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population.

Authors:  R O Illing; J E Kennedy; F Wu; G R ter Haar; A S Protheroe; P J Friend; F V Gleeson; D W Cranston; R R Phillips; M R Middleton
Journal:  Br J Cancer       Date:  2005-10-17       Impact factor: 7.640

View more
  2 in total

1.  Effects of phase aberration on transabdominal focusing for a large aperture, lowf-number histotripsy transducer.

Authors:  Ellen Yeats; Dinank Gupta; Zhen Xu; Timothy L Hall
Journal:  Phys Med Biol       Date:  2022-07-19       Impact factor: 4.174

2.  "HIFU Beam:" A Simulator for Predicting Axially Symmetric Nonlinear Acoustic Fields Generated by Focused Transducers in a Layered Medium.

Authors:  Petr V Yuldashev; Maria M Karzova; Wayne Kreider; Pavel B Rosnitskiy; Oleg A Sapozhnikov; Vera A Khokhlova
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-08-27       Impact factor: 3.267

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.