Literature DB >> 28267829

Success and Survival of Various Types of All-Ceramic Single Crowns: A Critical Review and Analysis of Studies with a Mean Follow-Up of 5 Years or Longer.

Alhanoof Aldegheishem, George Ioannidis, Wael Att, Haralampos Petridis.   

Abstract

PURPOSE: The aim of this critical review was to assess the survival and success rates of all-ceramic single crowns manufactured using different ceramic materials with a mean follow-up time of 5 years or longer.
MATERIALS AND METHODS: An electronic search of studies published between 1980 and 2014 complemented by manual searching was conducted in Medline and Scopus. The terms ceramic, crown, survival, success, longevity, and complications were selected as keywords. Predetermined inclusion and exclusion criteria guided the search. Data were extracted and assessed by two independent reviewers. The results were statistically analyzed according to the type of material, and survival/success rate was calculated by assuming a Poisson-distributed number of events.
RESULTS: The initial search yielded 972 articles. After subsequent filtering, 14 studies were selected. The inter-reviewer agreement was rated as good (κ = 0.65) and very high agreement (κ = 0.93) during the identification and screening phases, respectively. No studies on densely sintered zirconia or feldspathic crowns satisfied the minimum follow-up time. Only one study of each of the following materials satisfied the inclusion criteria: lithium disilicate, leucite reinforced, pressed Al₂O₃, and sintered Al₂O₃. Meta-analysis of the included studies on other materials resulted in the following estimated survival and success rates: for densely sintered alumina crowns, 93.8% and 92.75%, respectively; for fluoromica reinforced, 87.7% and 87.7%, respectively; and for glass-infiltrated alumina core, 94.4% and 92%, respectively. Crown fracture was considered the most frequent complication.
CONCLUSION: Based on the present critical review, there was no evidence to support the superior application of a single ceramic system or material. Further long-term prospective studies are required.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28267829     DOI: 10.11607/ijp.4703

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  8 in total

1.  Clinical evaluation of zirconia-based all-ceramic single crowns: an up to 12-year retrospective cohort study.

Authors:  Shoko Miura; Shin Kasahara; Shinobu Yamauchi; Yayoi Okuyama; Akio Izumida; Jun Aida; Hiroshi Egusa
Journal:  Clin Oral Investig       Date:  2017-06-12       Impact factor: 3.573

2.  Influence of Intra-Oral Scanner (I.O.S.) on The Marginal Accuracy of CAD/CAM Single Crowns.

Authors:  Francesco Ferrini; Gianpaolo Sannino; Carlo Chiola; Paolo Capparé; Giorgio Gastaldi; Enrico Felice Gherlone
Journal:  Int J Environ Res Public Health       Date:  2019-02-14       Impact factor: 3.390

3.  IPS e.max for All-Ceramic Restorations: Clinical Survival and Success Rates of Full-Coverage Crowns and Fixed Partial Dentures.

Authors:  Silvia Brandt; Anna Winter; Hans-Christoph Lauer; Fritz Kollmar; Soo-Jeong Portscher-Kim; Georgios E Romanos
Journal:  Materials (Basel)       Date:  2019-02-02       Impact factor: 3.623

4.  Comprehensive CAD/CAM Prosthetic Rehabilitation Management in a Young Patient with Agenesis: A Case Report.

Authors:  Noémie Drancourt; Emmanuel Nicolas; Jean-Luc Veyrune; Marion Bessadet
Journal:  Healthcare (Basel)       Date:  2022-02-17

5.  Influence of Material Selection on the Marginal Accuracy of CAD/CAM-Fabricated Metal- and All-Ceramic Single Crown Copings.

Authors:  Matthias Rödiger; Lea Schneider; Sven Rinke
Journal:  Biomed Res Int       Date:  2018-03-22       Impact factor: 3.411

6.  Influence of the CAD-CAM Systems on the Marginal Accuracy and Mechanical Properties of Dental Restorations.

Authors:  Roberto Padrós; Luís Giner; Mariano Herrero-Climent; Carlos Falcao-Costa; José-Vicente Ríos-Santos; Francisco Javier Gil
Journal:  Int J Environ Res Public Health       Date:  2020-06-15       Impact factor: 3.390

7.  Prospective Clinical Evaluation of Posterior Third-Generation Monolithic Zirconia Crowns Fabricated with Complete Digital Workflow: Two-Year Follow-Up.

Authors:  Mustafa Gseibat; Pablo Sevilla; Carlos Lopez-Suarez; Verónica Rodríguez; Jesús Peláez; María J Suárez
Journal:  Materials (Basel)       Date:  2022-01-17       Impact factor: 3.623

8.  Evaluation of the clinical success of four different types of lithium disilicate ceramic restorations: a retrospective study.

Authors:  Sharo Abdulrahman; Constantin Von See Mahm; Ranjdar Talabani; Darwn Abdulateef
Journal:  BMC Oral Health       Date:  2021-12-07       Impact factor: 2.757

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.