Literature DB >> 28266348

Dose coverage calculation using a statistical shape model-applied to cervical cancer radiotherapy.

David Tilly1, Agustinus J A J van de Schoot, Erik Grusell, Arjan Bel, Anders Ahnesjö.   

Abstract

A comprehensive methodology for treatment simulation and evaluation of dose coverage probabilities is presented where a population based statistical shape model (SSM) provide samples of fraction specific patient geometry deformations. The learning data consists of vector fields from deformable image registration of repeated imaging giving intra-patient deformations which are mapped to an average patient serving as a common frame of reference. The SSM is created by extracting the most dominating eigenmodes through principal component analysis of the deformations from all patients. The sampling of a deformation is thus reduced to sampling weights for enough of the most dominating eigenmodes that describe the deformations. For the cervical cancer patient datasets in this work, we found seven eigenmodes to be sufficient to capture 90% of the variance in the deformations of the, and only three eigenmodes for stability in the simulated dose coverage probabilities. The normality assumption of the eigenmode weights was tested and found relevant for the 20 most dominating eigenmodes except for the first. Individualization of the SSM is demonstrated to be improved using two deformation samples from a new patient. The probabilistic evaluation provided additional information about the trade-offs compared to the conventional single dataset treatment planning.

Entities:  

Mesh:

Year:  2017        PMID: 28266348     DOI: 10.1088/1361-6560/aa64ef

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Performance evaluation of a newly developed three-dimensional model-based global-to-local registration in prostate cancer.

Authors:  Mitsuhiro Nakamura; Megumi Nakao; Hideaki Hirashima; Hiraku Iramina; Takashi Mizowaki
Journal:  J Radiat Res       Date:  2019-10-23       Impact factor: 2.724

2.  Probabilistic optimization of dose coverage in radiotherapy.

Authors:  David Tilly; Åsa Holm; Erik Grusell; Anders Ahnesjö
Journal:  Phys Imaging Radiat Oncol       Date:  2019-04-13

3.  Novel adaptive beam-dependent margins for additional OAR sparing.

Authors:  H S Tsang; C P Kamerling; P Ziegenhein; S Nill; U Oelfke
Journal:  Phys Med Biol       Date:  2018-10-29       Impact factor: 3.609

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.