[Purpose] This study aimed to develop and validate an assessment tool for Moiré topogram made specifically with the Shadow Moiré technique of the dorsum.
[Subjects and Methods] In the analysis of topograms, frontal, sagittal, and transverse planes of individuals' dorsal were considered. Two instructor evaluators analyzed the topograms at different times in the day and on different days. The measurements of intra- and inter- (intra- and interday) reliability were calculated.
[Results] Of the three planes analyzed, in all analyses, good (0.61 to 0.80) and/or excellent (0.81 to 1) concordances were observed.
[Conclusion] This analysis framework can be recommended to evaluate the topograms obtained with SMT.

Entities:  

Keywords:  Moiré topography; Posture; Reproducibility of results

Year:  2017        PMID: 28265173      PMCID: PMC5333004          DOI: 10.1589/jpts.29.356

Source DB:  PubMed          Journal:  J Phys Ther Sci        ISSN: 0915-5287


INTRODUCTION

Currently, radiographic examination is the gold standard for identifying deviations in the posture of the spine, allowing visualization of the patient’s vertebrae while standing in addition to measuring the bending angle and segment speeds1). However, despite its obvious contribution to diagnostic medicine, ionizing radiation inherent to the radiographic examination may cause damage to health. As an example, in less than 65 years after the discovery of X-rays in 1895, 360 deaths were registered among health professionals and patients as a result of exposure to radiation during radiographic recording2). Radiation has a cumulative effect, and the younger the patient is who is exposed to it, the greater the damage to the body, which includes modifying genetic material and causing cell death3). The test may be riskier for children because their bodies have increased radiosensitivity, and it is possible that they will accumulate a great deal of exposure to radiation during their lifetimes3, 4). Such risks make advances in diagnostics essential. The creation and validation of techniques and indirect methods are of particular interest, especially for monitoring the evolution of idiopathic scoliosis in young people, as these conditions produce demand for conducting periodic radiographic examinations using three phase X-rays and the high-speed X-ray5). The high financial cost is another factor that complicates the periodic use of panoramic radiography of the spine for the patient. This factor has increased examining spinal posture by imaging parts of the spine instead of imaging the entire spine in a single image (panoramic). The need to pay highly trained professionals6), and costs for preparing the environment, including shielding walls, light box, screens, cameras, and other items, all contribute to this cost. This reinforces the importance of developing alternative techniques to assess posture that are financially viable and safe for the health of the individual. Evaluation of body posture is part of the standard practice of various health professionals, such as physical education teachers, physiotherapists, and doctors. These professionals use assessment of posture to identify postural deviations or monitor the progression of students and patients in realigning their bodies through physical exercise or physical rehabilitation programs. This assessment, even if not performed through X-ray examination, may be useful to provide an indication of various changes in posture. The Moiré topography (MT) appears to be a viable and complementary alternative to radiographic examination in evaluating trunk posture7, 8). It is based on optical phenomena, and Moiré provides a three-dimensional shape analysis of objects from a two-dimensional image8,9,10). Analysis of the Moiré topograms obtained from the individual’s back allows verification of asymmetries and postural unevenness, and can be performed in a manner that is either predominantly qualitative11, 12) or quantitative7, 13). One of the techniques employed by TM is the Shadow Moiré technique (SMT). Unlike X-rays, the SMT offers no risk to the health of the individual6) and therefore, patients can be evaluated several times, which is essential for monitoring the realignment of posture. Additionally, its low cost6, 12, 14) makes it suitable for use in schools and basic health units. This facilitates diagnosis of suspected postural deviations, even in childhood, aiding the early detection and treatment of such diseases11, 15). SMT can also be used in the elderly, which is significant considering the high prevalence of structural postural deviations in these individuals7). This study aimed to develop and validate an assessment tool for Moiré topogram made specifically with the SMT of the dorsum. Despite the advantages of using this technique, there is a great likelihood of mistakes due to fatigue when evaluating a large number of topograms qualitatively10, 13). Moreover, to date, we have not found a tool that guides the best qualitative assessment of Moiré topograms. The central question of this article is, therefore: is there reliability in the qualitative evaluation of Moiré topograms?

SUBJECTS AND METHODS

This is a reliability study and therefore aims to measure the consistency of the results when the method is repeated more than once, either by the same person or by different evaluators16, 17). We analyzed 15 topograms obtained from the postural assessment of the spine of 15 professionals in nursing, including nurses and nursing technicians, all employees of a polyclinic in the city of Niterói, RJ. Subjects included three males and 12 females, between 32 and 61 years of age. Data collection occurred in September of 2014. The research procedures followed the relevant guidelines and regulatory standards for research conducted in Brazil with human subjects, under Resolution 466 of December 12, 2012, of the National Council of Health18). The study was approved as No. 679,764/2014 by the Ethics Committee for Institutional Research. At the end of the study, the volunteers were given the results of their assessments. Two examiners analyzed 15 Moiré topograms. The examiners were previously trained physical education professionals. One qualitative assessment script was used to determine postural deviations in the frontal, sagittal, and transverse planes19). This script divides the analysis into the following steps: 1) The frontal plane was observed, seeking the following in the order shown: a) asymmetries of the spine—in this case, the presence of concavity of the right or left sides in the cervical, thoracic, and lumbar spines; b) alignment of the spine—the alignment of Moiré fringes in the three regions of the spinal column describing whether there was a side (left or right) higher than the other, or if they were flattened if symmetrical; c) asymmetries of the blades—if there was unevenness between the shoulder blades, if a scapula (left or right) was higher than the other, or if they were flattened if symmetrical. 2) In the sagittal plane, asymmetries related to the physiological curvature (lordosis and kyphosis) of three regions of the spine were analyzed. 3) In the transverse plane, the leveling of the shoulder blades was identified through the number of centroids present in the topogram, corresponding to the presence of spinal deformity. To determine inter-rater reliability (A vs. B), both received topograms and a sheet to report results via e-mail. To determine the stability of intra-rater measure (A vs. A), the examiner received topograms and sheet to report results again after 48 hours from the time of their first assessment. All evaluations were performed in the afternoon between the 1:00 and 6:00 PM. In both initial and repeated measurements, the two examiners performed the evaluations independently, blind to the allocation of topograms and the result of their fellow examiner. All conditions of assessment, data tabulation, and statistical analyses were guaranteed by the present study coordinator. A Kappa Cohen agreement test, with intra- and inter-raters on intraday and interday tests and retests was conducted, using a mixed effects model with two inputs. For the analyses, the established statistical significance was set at p ≤0:05, using the statistical package (SPSS 20.0, SPSS Inc., Chicago, IL, USA). To anthropometric assessment, height, body mass, abdominal perimetry, and hip measurements were taken, and body mass index (BMI) and waist-hip ratio (WHR) were calculated according to the International Standards recommendations for Anthropometric Assessment20). To perform this, a portable stadiometer (EST 22 Cachoeira do Sul, RS, Brazil) with a maximum capacity of 2 m and a minimum capacity of 0.3 m, with an accuracy of 0.001 m, was used, as well as a mechanical scale (Filizola, mod 31, Osasco, SP, Brazil) with an accuracy of 100 g and a maximum capacity of 150 kg and anthropometric tape (CESCORF Ltda., Porto Alegre, RS, Brazil). BMI calculation was based on the World Health Organization’s standards21) for adults over 18 years old. The method for obtaining the Moiré topograms followed the proposals of previous studies7, 14, 22). The following equipment was used to obtain the topograms: a camera (Sony Cyber-shot model, 14.1MP, Psc model W350, Manaus, AM, Brazil) fixed to a tripod, a light source (100 W, Bellalux, Osasco, SP, Brazil), a grid (lattice) constructed with nylon yarn (Grilon 210/36, 1:35 mm, 200 g, São Paulo, SP, Brazil) with a period of 1 mm and painted with opaque black ink. In a darkened room, the volunteer remained standing, shirtless and barefoot, his spine to the reticle as the light fell obliquely on his back. A photo was obtained in a plane perpendicular to the grid. All samples were taken by a professional in physical education. Figure 1 shows the experiment setup used for capturing Moiré topograms.
Fig. 1.

The method of postural evaluation with SMT

The method of postural evaluation with SMT At the end of the evaluations, seeking to ensure the ethical principles of research involving human subjects and volunteers, clinical information of the results obtained in the evaluations was made available to the test subjects.

RESULTS

Table 1 shows the characteristics of the volunteers assessed.
Table 1.

Characteristics of individuals participating in the research (n=15)

VariableAverage (SD)Min & Maxmd (Q1 & Q3)
Age (years)47 ± 9.532–6150 (38–55)
Weight (kg)75.3 ± 15.360–9567 (59.5–79)
Height (m)1.6 ± 0.11.51−1.721.60 (1.55–1.65)
BMI (kg/m2)26.6 ± 5.117.9−34.425.8 (25.8–31.1)

MC: body mass; SD: standard deviation; Min: Minimum; Max: Maximum; md: Median; Q1 (1st quartile); Q3 (3rd quartile); BMI: body mass index

MC: body mass; SD: standard deviation; Min: Minimum; Max: Maximum; md: Median; Q1 (1st quartile); Q3 (3rd quartile); BMI: body mass index The intra- and interreliability related to postural evaluations is shown in Table 2, whose concordance measurements were obtained using Cohen’s kappa test 23).
Table 2.

Qualitative assessment of the reliability of topograms obtained with SMT.

Deviation by planes and regions of the spineKappa

IntraInter
Front plane
Asymmetries of VC0.82a*0.81a*
Cervical region0.71b*0.69b*
Thoracic region0.88a*0.89a*
Lumbar region
Front plane1.00a*1.00a*
Alignment VC1.00a*1.00a*
Cervical region0.76b*0.77b*
Thoracic region
Lumbar region1.00a*0.63b*
Front plane
Unevenness of scapulas0.76b*1.00a*
Flush or unlevel0.66b*0.85a*
Sagittal plane0.72b*0.90a*
Asymmetries of VC
Cervical region1.00a*1.00a*

*Statistically significant (p<0.05); aCompliance Good (0.81 to 1); bSubstantial Concordance (0.61 to 0.80); cModerate Concordance (0.41 to 0.60). dRegular Concordance (0.21 to 0.40); VC: Vertebral Column; when the scapulae are level, the number of centroids (corresponding to the presence of spinal deformity) coincides on both sides.

*Statistically significant (p<0.05); aCompliance Good (0.81 to 1); bSubstantial Concordance (0.61 to 0.80); cModerate Concordance (0.41 to 0.60). dRegular Concordance (0.21 to 0.40); VC: Vertebral Column; when the scapulae are level, the number of centroids (corresponding to the presence of spinal deformity) coincides on both sides.

DISCUSSION

It is concluded that the SMT analysis framework in this study showed an inter- and intra-reliability considered to be between good and/or excellent. Thus, it may be considered reliable and can be recommended for qualitative evaluations of the topograms obtained with SMT for body posture of the back. In health literature, there is currently an increase of studies conducted to verify and evaluate scales, questionnaires and other qualitative research tools24). To perform high-quality research, it is important that procedures and instruments be reliable to decrease the risk of bias in outcomes25). This adds credibility and legitimacy to the study26). Confirming the reliability of a measurement is important so that results of a technique can be considered accurate and consistent between times and locations and therefore, the phenomenon being studied may have better follow through values between surveys24). Concerning the reliability of posture evaluation, some factors give reason to question the veracity of the findings, such as the assessment being carried out essentially by observation27). This is because it is an assessment with very high subjective content, and therefore, tools to assess quality control must accompany it. Several factors may be involved in the evaluation of postural deviations, such as anthropometric factors and the positioning of the feet of the individual during the evaluation28). The predominantly qualitative assessments require greater control over variables, making it necessary to include criteria and procedures to reduce limitations commonly seen in postural assessments that can compromise the description of the phenomenon studied. Thus, in the present study, we sought to mitigate these problems by adequately controlling possible variables, providing instructions to volunteers beforehand such as guiding them to remain in a comfortable position. In procedures that use photography, it is common for the volunteer—at that moment—to try and stay in a more upright posture, thus changing the outcome of the analysis. Furthermore, it was of concern to not force them to position themselves with their feet in a certain way so that there was no forced change in their posture27). The use of topograms for evaluation of body posture can be considered a positive aspect of our study, since according to Iunes et al.29) and Sacco et al.30), the use of photos in the assessment of posture, as it becomes the most reliable data, ends up facilitating the analysis and storage of data, saves space and time, and allows access to files, which are important factors for conducting new research. The topograms analyzed in this study were drawn from 15 nurses working in a polyclinic in the city of Niterói, RJ. It is known that for purposes of analyzing the reliability of this technique, the posture of these professionals did not significantly improve. It is suggested that further studies be conducted with individuals of different characteristics, such as age, work activity, and others factors because the functional demands of people throughout life interfere with an individual’s body posture. Furthermore, it is possible that other deformities present in these subjects are less sensitive to the proposed method. Although Takasaki31) has proposed SMT for clinical examinations of body posture, to date, we have not found any tool to guide the best qualitative assessment of Moiré topograms. Therefore, the main aim of the present study is the verification of the reliability of measurements made using a proposed Moiré topogram qualitative assessment tool. It is noteworthy that, although studies have not been found that have investigated the reliability of this method, the reason for this appears not to be due to an opinion of scientific irrelevance, but rather the lack of knowledge about the technique by researchers in general. The MT has many advantages: it is not invasive, does not require much training of evaluators8), has a low cost, and requires little time to obtain images6, 8). The findings in this study could show that the use of Moiré topograms as a qualitative assessment tool has proved fairly reliable in both intra- and inter-rater assessments for all studied postural deviations. Although the results presented reliable agreements at all levels, it was noted that the consistency of opinions regarding asymmetries in the sagittal plane was slightly lower than that of opinions regarding other planes. This outcome is consistent with other studies that, even using other evaluation tools of the spine, also found little reliability in measures relating to spinal curvatures in the sagittal plane29, 32, 33). This lower reliability of measurements of the spine in the sagittal plane, according to Teo and Ng34), can be justified as most indirect methods address a one-dimensional evaluation and the changes of the spine are usually three-dimensional. In the present study, it is believed that although the Moiré topograms make a three-dimensional analysis of the dorsum possible8), the evaluator may find it difficult to view asymmetries in the sagittal plane, due to lower sharpness of fringes, especially in the cervical and lumbar regions, which could justify considering the measurements of the sagittal plane less reliable when compared to the measures of other planes. Also, a detail was noticed about the instrument used that may be important for clinical practice. It was noted that the analyses performed in the sagittal plane, especially in the cervical and lumbar regions, end up being a limiting factor evaluation with the SMT. Even with a reliable intra- and inter-rater agreement, it was found that in most analyzed topograms, both evaluators marked the option “could not see” on the reporting sheet. For evaluations of topograms of the cervical region, there was a high presence of option “could not be seen”—73.3% of topograms (n=11) were marked as such by both evaluators (A vs. B), and summed between both evaluators, 80% of topograms (n=12) were marked as such by the same evaluator (A vs. A). In the lumbar region, although showing a lesser percentage, there was also a considerable presence of the option “could not see”, yielding a total of 47% (n=7) between evaluators (A vs. B) and 40% (n=6) in intra-rater assessments. The inability to see the fringes of Moiré by the evaluators is thought to be due to a mistake made by the evaluator in obtaining topograms, the deformities presented by the subjects, or even limitations of the method. Moiré techniques have proved in other studies to be more effective than simply viewing posture evaluation to verify asymmetries of the cervical and lumbar spine6, 32). Although SMT is also predominantly qualitative, in this study, there was a strict control of methodological variables, which may explain the higher levels of reliability that were found. The technique analyzed in this study is reliable; it is suggested that the dissemination and use of SMT can test trunk posture without the need to expose individuals to ionizing radiation and when they need information on the bone quality of the individual. As more than 90% examiners use visual estimation as a tool to assess the posture of the spine32), the ease and reliability of SMT, as shown here, can be an incentive to make it a substitute for other methods for this kind of evaluation.
  16 in total

1.  Evaluation of the role of ligaments, facets and disc nucleus in lower cervical spine under compression and sagittal moments using finite element method.

Authors:  E C Teo; H W Ng
Journal:  Med Eng Phys       Date:  2001-04       Impact factor: 2.242

2.  Moiré topography.

Authors:  H Takasaki
Journal:  Appl Opt       Date:  1970-06-01       Impact factor: 1.980

3.  [Control of health risks in radiodiagnosis: a historic approach].

Authors:  Marcus Vinicius Teixeira Navarro; Handerson Jorge Dourado Leite; Josemir da Cruz Alexandrino; Ediná Alves Costa
Journal:  Hist Cienc Saude Manguinhos       Date:  2008 Oct-Dec

Review 4.  Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine.

Authors:  G Atkinson; A M Nevill
Journal:  Sports Med       Date:  1998-10       Impact factor: 11.136

Review 5.  Radiographic evaluation of scoliosis: review.

Authors:  David Malfair; Anne K Flemming; Marcel F Dvorak; Peter L Munk; Alexandra T Vertinsky; Manraj K Heran; Doug A Graeb
Journal:  AJR Am J Roentgenol       Date:  2010-03       Impact factor: 3.959

Review 6.  [Content validity in the development and adaptation processes of measurement instruments].

Authors:  Neusa Maria Costa Alexandre; Marina Zambon Orpinelli Coluci
Journal:  Cien Saude Colet       Date:  2011-07

7.  Obesity: preventing and managing the global epidemic. Report of a WHO consultation.

Authors: 
Journal:  World Health Organ Tech Rep Ser       Date:  2000

8.  [Screening of school children for scoliosis. Examination of the back with moiré topography and controlled forward bending test].

Authors:  E Berntsen; B Risgaard-Petersen
Journal:  Ugeskr Laeger       Date:  1981-12-07

Review 9.  Carcinogenic risks of prenatal ionizing radiation.

Authors:  Robert L Brent
Journal:  Semin Fetal Neonatal Med       Date:  2013-12-27       Impact factor: 3.926

Review 10.  SOSORT 2012 consensus paper: reducing x-ray exposure in pediatric patients with scoliosis.

Authors:  Patrick Knott; Eden Pappo; Michelle Cameron; Jc Demauroy; Charles Rivard; Tomasz Kotwicki; Fabio Zaina; James Wynne; Luke Stikeleather; Josette Bettany-Saltikov; Theodoros B Grivas; Jacek Durmala; Toru Maruyama; Stefano Negrini; Joseph P O'Brien; Manuel Rigo
Journal:  Scoliosis       Date:  2014-04-25
View more
  2 in total

1.  Moiré topography as a screening and diagnostic tool-A systematic review.

Authors:  Marta Kinga Labecka; Magdalena Plandowska
Journal:  PLoS One       Date:  2021-12-02       Impact factor: 3.240

2.  Somatic determinants of changes in selected body posture parameters in younger school-age children.

Authors:  Marta Kinga Labecka; Krystyna Górniak; Małgorzata Lichota
Journal:  PeerJ       Date:  2021-02-10       Impact factor: 2.984

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.