Jin Mo Yang1, Hyun-Gyu Cha2, Myoung-Kwon Kim3. 1. IAME Training Center, Republic of Korea. 2. Department of Physical Therapy, Kyungbuk College, Republic of Korea. 3. Department of Physical Therapy, College of Rehabilitation Sciences, Daegu University, Republic of Korea.
Abstract
[Purpose] This study examined the effects of manipulation of the thorax and the intensity of the pressure biofeedback unit on the superficial cervical flexors muscle during craniocervical flexion exercise. [Subjects and Methods] Thirty three subjects participated in the experiment. Thirty three healthy people without any orthopedic history were also selected. The subjects could monitor the pressure applied to cervical vertebra 3 of the craniocervical junction by markings on the pressure biofeedback unit. Craniocervical flexion exercise was performed for 20 seconds per pressure, and two minutes of rest was allowed after exercise to reduce muscle fatigue. [Results] Significant differences in the post-training gains in the sternocleidomastoid and scalene were observed between the thorax fixation group and thorax non-fixation group. The thorax fixation group showed that muscle activation of the sternocleidomastoid and scalene was increased when the pressure biofeedback unit intensity was 40 mmHg than when pressure biofeedback unit intensity was 20 mmHg and 30 mmHg in the post-hoc result. The thorax non-fixation group showed that muscle activation of the sternocleidomastoid and scalene was higher when the pressure biofeedback unit intensity was 40mmHg compared to that when the pressure biofeedback unit intensity was 20mmHg in the post-hoc result. [Conclusion] Craniocervical flexion exercise is a clinically effective method that reduces the superficial neck flexor muscle activation.
[Purpose] This study examined the effects of manipulation of the thorax and the intensity of the pressure biofeedback unit on the superficial cervical flexors muscle during craniocervical flexion exercise. [Subjects and Methods] Thirty three subjects participated in the experiment. Thirty three healthy people without any orthopedic history were also selected. The subjects could monitor the pressure applied to cervical vertebra 3 of the craniocervical junction by markings on the pressure biofeedback unit. Craniocervical flexion exercise was performed for 20 seconds per pressure, and two minutes of rest was allowed after exercise to reduce muscle fatigue. [Results] Significant differences in the post-training gains in the sternocleidomastoid and scalene were observed between the thorax fixation group and thorax non-fixation group. The thorax fixation group showed that muscle activation of the sternocleidomastoid and scalene was increased when the pressure biofeedback unit intensity was 40 mmHg than when pressure biofeedback unit intensity was 20 mmHg and 30 mmHg in the post-hoc result. The thorax non-fixation group showed that muscle activation of the sternocleidomastoid and scalene was higher when the pressure biofeedback unit intensity was 40mmHg compared to that when the pressure biofeedback unit intensity was 20mmHg in the post-hoc result. [Conclusion] Craniocervical flexion exercise is a clinically effective method that reduces the superficial neck flexor muscle activation.
Entities:
Keywords:
Craniocervical; Electromyography; Pressure biofeedback unit
The deep neck flexor is made up of the longus colli, longus capitis, and rectus capitis
anterior, and the superficial neck flexor is made up of the sternocleidomastoid (SCM) and
scalene muscle1). Unlike the superficial
neck flexor muscle, the deep neck flexors, which are attached to the cervical spine, support
the cervical lordosis directly and give stability2).Previous studies reported that 70% of patients with neck pain and headache showed a
decrease in strength and endurance of the SCM and scalenus1). After applying craniocervical flexion exercise to patients with
neck pain using a pressure biofeedback unit (PBU), there has been a significant increase in
the strength of the deep neck flexor muscle in the forward head posture3). Another study claimed that when the thorax is not fixed
during craniocervical flexion exercise, contraction of the SCM and anterior scalenus
increased, among other superficial neck flexors4). On the other hand, the same study did not report conclusive results
on whether manipulation of the thorax during craniocervical flexion exercise affects muscle
activation. This study examined the effects of manipulation of the thorax and the intensity
of PBU on the superficial cervical flexors muscle during craniocervical flexion
exercise.
SUBJECTS AND METHODS
Thirty-three subjects participated in the experiment. This study also selected ten healthy
people without any orthopedic history. Information on the study was provided to all subjects
prior to their participation and written informed consent according to the ethical standards
of the Declaration of Helsinki, to participate in the project was obtained. The average
ages, heights, and weights were 29.91 ± 4.4 years old, 171.55 ± 7.78 cm, and 62.82 ± 8.57 kg
in the experimental group, respectively. The Research Ethics Committee of Eulji University
Hospital approved the study. For craniocervical flexion exercises, PBU (Chattanooga Group
Inc., Hixson, USA), which was adopted in a previous study, was used to apply an increasing
pressure of 20, 30, and 40 mmHg2).The subjects could monitor the pressure applied to cervical vertebra 3 of the
craniocervical junction by markings on PBU. Craniocervical flexion exercise was performed
for 20 seconds per pressure, and two minutes of rest was allowed after exercise to reduce
muscle fatigue. The subjects were instructed to flex both of their hip joints and knee
joints to limit the contraction of rectus abdominis in the supine position. The subjects
pulled their chins downward during the exercise to contract the lungus colli and longus
capitis. Care was taken to minimize neck bending by contraction of the superficial muscles,
such as the SCM and ant. Scalene4). The
thorax of the subjects was fixed using a manual belt. To reduce the discomfort by pressure
caused by the manual belt, a towel was placed between the belt and thorax to ensure that the
subjects experienced no discomfort prior to the experiment.In this study, electromyography (QEMG-4 System, LXM 3204 Laxtha, Korea) was used to measure
the change in the values of muscle activation in the superficial muscles. Electromyogram
electrodes were attached to the following areas5): (1) SCM, between mastoid process and sternal notch; and (2) Ant.
Scalene, behind the SCM, above the clavicle, and triangle shape formed by the upper
trapezius. The electrodes were attached to the superficial muscles and the subjects bent
their cervical vertebra for 20 seconds while their muscle activation value was recorded. The
distance between the electrodes was 2 cm, and the sampling rate and band pass filter were
set to 1,024 Hz and 20–450 Hz, respectively. In addition, the signals collected from each
muscle were normalized to the maximal voluntary isometric contraction (%MVIC). SPSS Win
version 12.0 was used for statistical analysis. To compare the change in superficial muscle
activation by the PBU intensity of the chest fixed group and non-fixed group, 3 × 2 two-way
repeated ANOVA was used, and a paired t-test was conducted to compare the difference in
muscle activation between the two groups. A p value<0.05 was considered significant.
RESULTS
Significant differences in the post-training gains in the SCM and scalene were observed
between the thorax fixation group and thorax non-fixation group (p<0.05).The post-hoc result showed that the thorax fixation group showed that muscle activation of
the SCM and scalene was higher when the PBU intensity was 40 mmHg than when the PBU
intensity was 20 mmHg and 30 mmHg (p<0.01). The thorax non-fixation group showed also
higher muscle activation of the SCM and scalene when the PBU intensity was 40 mmHg than when
the PBU intensity was 20 mmHg (p<0.05) (Table
1).
Table 1.
Comparison of the craniocervical flexion exercise groups (n=33) (units:
%MVIC)
22 mmHga
30 mmHgb
40 mmHgc
SCM
Fixation
5.41 ± 1.43#
6.67 ± 4.24
8.60 ± 4.96
c>a,b**
Non-fixation
6.83 ± 3.05**
9.32 ± 9.78*
11.80 ± 10.93*
c>a*
Scalenus
Fixation
6.37 ± 1.83
7.46 ± 2.54
10.06 ± 4.47
c>a,b**
Non-fixation
8.21 ± 3.59**
9.27 ± 4.36**
12.33 ± 5.80**
c>a*
#Mean ± SD: Mean ± standard deviation. *Significant intergroup difference
between the gains achieved (p<0.05)
#Mean ± SD: Mean ± standard deviation. *Significant intergroup difference
between the gains achieved (p<0.05)
DISCUSSION
Patients with neck pain exhibit reduced cervical region control ability due to a weakening
of the deep neck flexor muscles6). The SCM
and anterior scalene, superficial muscles, are activated excessively in the early stages,
limiting the bending of the cervical region. Such abnormal movement extends the chin
forward, shortening the cervical muscle that is between the occipital region and cervical
vertebra 1, and weakening the lungus colli and longus capitis7). Falla et al. applied craniocervical flexion exercise to the normal
cervical spine and witnessed an increase in muscle activation of the lungus colli and longus
capitis8).As a result, during craniocervical flexion exercise using PBU, the cervical region
superficial muscle activation was lower when the thorax was fixed than when it was not. A
previous study reported that lower muscle activation of the superficial neck flexor during
craniocervical flexion9). This is because
when thorax is fixed, activation of the SCM and scalenus decreases, which was also observed
in the present study9). Therefore,
craniocervical flexion exercise performed by neck painpatients with their thorax fixed is a
clinically effective method that reduces the superficial neck flexor muscle activation10).