Is quantitative coronary angiography reliable in assessing the late lumen loss of the everolimus-eluting bioresorbable polylactide scaffold in comparison with the cobalt-chromium metallic stent?

Yohei Sotomi1, Yoshinobu Onuma, Yosuke Miyazaki, Taku Asano, Yuki Katagiri, Erhan Tenekecioglu, Hans Jonker, Jouke Dijkstra, Robbert J de Winter, Joanna J Wykrzykowska, Gregg W Stone, Jeffrey J Popma, Ken Kozuma, Kengo Tanabe, Patrick W Serruys, Takeshi Kimura.   

Abstract

AIMS: Immediately after stent/scaffold implantation, quantitative coronary angiography (QCA) in comparison to optical coherence tomography (OCT) more severely underestimates the lumen diameter (LD) in Absorb than in XIENCE. This OCT-QCA discrepancy has not been evaluated at long-term follow-up. The present study aimed to assess the accuracy of QCA with reference to OCT in Absorb as compared to XIENCE. METHODS AND
RESULTS: We assessed two-year QCA and OCT in the ABSORB Japan randomised trial (Absorb n=87, XIENCE n=44). The accuracy of QCA parameters was assessed with reference to OCT measurements. OCT-QCA luminal dimensions were compared in matched cross-sections at both edges of the scaffolds (n=127) and stents (n=78). OCT-QCA late lumen loss (LLL) was also assessed using the Bland-Altman method. The systematic error of LD on QCA in Absorb was -0.092 mm (relative difference -3.3%) with a random error of 0.473 mm, whereas in XIENCE the systematic error was -0.018 mm (-0.5%) with a random error of 0.477 mm. These OCT-QCA discrepancies did not differ between Absorb and XIENCE (p=0.275) at two-year follow-up. QCA tended to underestimate LLL more in Absorb than in XIENCE (QCA-LLL minus OCT-LLL: -0.180±0.308 mm vs. -0.058±0.322 mm, p=0.058) at two-year follow-up, although this comparison was not statistically powered.
CONCLUSIONS: The two-year dimensional measurements on QCA had minor and insignificant systematic errors between both devices. A discrepancy between QCA-LLL and OCT-LLL would raise a question as to whether this parameter is appropriate for the comparative assessment of device performance.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28262625     DOI: 10.4244/EIJ-D-17-00070

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  1 in total

1.  Effect of Stenting Strategy on the Outcome in Patients with Non-Left Main Bifurcation Lesions.

Authors:  Yongwhan Lim; Min Chul Kim; Youngkeun Ahn; Doo Sun Sim; Young Joon Hong; Ju Han Kim; Myung Ho Jeong; Hyeon-Cheol Gwon; Hyo-Soo Kim; Seung Woon Rha; Jung Han Yoon; Yangsoo Jang; Seung-Jea Tahk; Ki Bae Seung
Journal:  J Clin Med       Date:  2022-09-26       Impact factor: 4.964

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.