Barbara Cervantes1, Jan S Kirschke2, Elizabeth Klupp2, Hendrik Kooijman3, Peter Börnert4, Axel Haase5, Ernst J Rummeny1, Dimitrios C Karampinos1. 1. Department of Diagnostic and Interventional Radiology, Technische Universität München, Munich, Germany. 2. Department of Neuroradiology, Technische Universität München, Munich, Germany. 3. Philips Healthcare, Hamburg, Germany. 4. Philips Research Laboratory, Hamburg, Germany. 5. Institute of Medical Engineering, Technische Universität München, Garching, Germany.
Abstract
PURPOSE: To design a preparation module for vessel signal suppression in MR neurography of the extremities, which causes minimal attenuation of nerve signal and is highly insensitive to eddy currents and motion. METHODS: The orthogonally combined motion- and diffusion-sensitized driven equilibrium (OC-MDSDE) preparation was proposed, based on the improved motion- and diffusion-sensitized driven equilibrium methods (iMSDE and FC-DSDE, respectively), with specific gradient design and orientation. OC-MDSDE was desensitized against eddy currents using appropriately designed gradient prepulses. The motion sensitivity and vessel signal suppression capability of OC-MDSDE and its components were assessed in vivo in the knee using 3D turbo spin echo (TSE). Nerve-to-vessel signal ratios were measured for iMSDE and OC-MDSDE in 7 subjects. RESULTS: iMSDE was shown to be highly sensitive to motion with increasing flow sensitization. FC-DSDE showed robustness against motion, but resulted in strong nerve signal loss with diffusion gradients oriented parallel to the nerve. OC-MDSDE showed superior vessel suppression compared to iMSDE and FC-DSDE and maintained high nerve signal. Mean nerve-to-vessel signal ratios in 7 subjects were 0.40 ± 0.17 for iMSDE and 0.63 ± 0.37 for OC-MDSDE. CONCLUSION: OC-MDSDE combined with 3D TSE in the extremities allows high-near-isotropic-resolution imaging of peripheral nerves with reduced vessel contamination and high nerve signal. Magn Reson Med 79:407-415, 2018.
PURPOSE: To design a preparation module for vessel signal suppression in MR neurography of the extremities, which causes minimal attenuation of nerve signal and is highly insensitive to eddy currents and motion. METHODS: The orthogonally combined motion- and diffusion-sensitized driven equilibrium (OC-MDSDE) preparation was proposed, based on the improved motion- and diffusion-sensitized driven equilibrium methods (iMSDE and FC-DSDE, respectively), with specific gradient design and orientation. OC-MDSDE was desensitized against eddy currents using appropriately designed gradient prepulses. The motion sensitivity and vessel signal suppression capability of OC-MDSDE and its components were assessed in vivo in the knee using 3D turbo spin echo (TSE). Nerve-to-vessel signal ratios were measured for iMSDE and OC-MDSDE in 7 subjects. RESULTS: iMSDE was shown to be highly sensitive to motion with increasing flow sensitization. FC-DSDE showed robustness against motion, but resulted in strong nerve signal loss with diffusion gradients oriented parallel to the nerve. OC-MDSDE showed superior vessel suppression compared to iMSDE and FC-DSDE and maintained high nerve signal. Mean nerve-to-vessel signal ratios in 7 subjects were 0.40 ± 0.17 for iMSDE and 0.63 ± 0.37 for OC-MDSDE. CONCLUSION: OC-MDSDE combined with 3D TSE in the extremities allows high-near-isotropic-resolution imaging of peripheral nerves with reduced vessel contamination and high nerve signal. Magn Reson Med 79:407-415, 2018.
Authors: Elisabeth Klupp; Barbara Cervantes; Nico Sollmann; Franziska Treibel; Dominik Weidlich; Thomas Baum; Ernst J Rummeny; Claus Zimmer; Jan S Kirschke; Dimitrios C Karampinos Journal: Clin Neuroradiol Date: 2018-07-23 Impact factor: 3.649
Authors: Sophie C Queler; Ek Tsoon Tan; Christian Geannette; Martin Prince; Darryl B Sneag Journal: Skeletal Radiol Date: 2021-05-07 Impact factor: 2.199
Authors: Jianmin Yuan; Yuxin Hu; Anne Menini; Christopher M Sandino; Jesse Sandberg; Vipul Sheth; Catherine J Moran; Marcus Alley; Michael Lustig; Brian Hargreaves; Shreyas Vasanawala Journal: Magn Reson Med Date: 2019-11-29 Impact factor: 4.668
Authors: Jesse K Sandberg; Victoria A Young; Ali B Syed; Jianmin Yuan; Yuxin Hu; Christopher Sandino; Anne Menini; Brian Hargreaves; Shreyas Vasanawala Journal: J Magn Reson Imaging Date: 2020-08-19 Impact factor: 5.119