Literature DB >> 28256439

Automated "Bone Subtraction" Image Analysis Software Package for Improved and Faster CT Monitoring of Longitudinal Spine Involvement in Patients with Multiple Myeloma.

Marius Horger1, Hendrick Ditt2, Shu Liao3, Katja Weisel4, Jan Fritz5, Wolfgang M Thaiss1, Sascha Kaufmann1, Konstantin Nikolaou1, Christopher Kloth6.   

Abstract

RATIONALE AND
OBJECTIVES: The study aimed to assess the diagnostic benefit of a novel computed tomography (CT) post-processing software generating subtraction maps of longitudinal non-enhanced CT examinations for monitoring the course of myeloma bone disease in the spine.
MATERIALS AND METHODS: The local institutional review board approved the retrospective data evaluation. Included were 82 consecutive myeloma patients (46 male; mean age, 65.08 ± 9.76) who underwent 188 repeated whole-body reduced-dose Multislice Detector Computed Tomography (MDCT) at our institution between December 2013 and January 2016. Lytic bone lesions were categorized as new or enlarging versus stable. Bone subtraction maps were read in combination with corresponding 1-mm source images comparing results to those of standard image reading of 5-mm axial and 2-mm multiplanar reformat reconstructions (MPR) scans and hematologic markers, and classified as either progressive disease (PD) or stable disease (SD or remission). The standard of reference was 1-mm axial CT image reading + hematologic response both confirmed at follow-up. For statistical purposes, we subgrouped the hematologic response categories similarly to those applied for CT imaging (progression vs stable/response).
RESULTS: According to the standard of reference, 16 patients experienced PD and 66 SD at follow-up. Th sensitivity, specificity, and accuracy for axial 5 mm + 2 mm MPR image versus bone subtraction maps in a "lesion-by-lesion" reading were 97.6%, 92.3%, and 97.2% versus 97.8%, 96.7%, and 97.7%, respectively. The use of bone subtraction maps resulted in a change of response classification in 9.7% of the patients (n = 8) versus 5 mm + 2 mm MPR image reading from SD to PD. Bone sclerosis lesions were detected in 52 out of 82 patients (63.4%). The reading time was significantly lower with the software bone subtraction compared to standard reading (P < 0.01) and 1-mm image reading (P < 0.001).
CONCLUSION: Accuracy of bone subtraction maps reading for monitoring multiple myeloma is slightly increased over that of conventional axial + MPR image reading and significantly speeds up the reading time.
Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CT imaging; Multiple myeloma; bone subtraction maps; lytic bone lesions; pelvic bones

Mesh:

Year:  2017        PMID: 28256439     DOI: 10.1016/j.acra.2016.12.003

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  2 in total

1.  Automatic rib unfolding in postmortem computed tomography: diagnostic evaluation of the OpenRib software compared with the autopsy in the detection of rib fractures.

Authors:  Martin Kolopp; Nicolas Douis; Ayla Urbaneja; Cédric Baumann; Pedro Augusto Gondim Teixeira; Alain Blum; Laurent Martrille
Journal:  Int J Legal Med       Date:  2019-11-16       Impact factor: 2.686

Review 2.  Printability and Shape Fidelity of Bioinks in 3D Bioprinting.

Authors:  Andrea Schwab; Riccardo Levato; Matteo D'Este; Susanna Piluso; David Eglin; Jos Malda
Journal:  Chem Rev       Date:  2020-08-28       Impact factor: 60.622

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.